Page 175 - Shimadu Consumables Catalog
P. 175

Capillary Columns
           General-Purpose Columns


              SH-225
              Polar phase: Crossbond™ 50% cyanopropylmethyl / 50% phenylmethyl polysiloxane    SH-225 Structure

              General-purpose columns for FAMEs, carbohydrates, sterols, flavor compounds.  $    /
              Equivalent to USP G7 and G19 phases.
                                                                                         $)

              Similar phases: DB-225, DB-225MS, CP-Sil 43 CB, SPB-225
                                                                                         4J  0        4J  0
                                                                                        $)           $)


               ID       df             Temp. Range                   30 m                      60 m
                      0.25 µm         40 to 220/240 °C            227-36229-01               227-36229-02
             0.25 mm
                      0.50 µm         40 to 220/240 °C            227-36230-01                   −
                      0.10 µm         40 to 220/240 °C            227-36231-01                   −
                      0.25 µm         40 to 220/240 °C            227-36232-01                   −
             0.32 mm
                      0.50 µm         40 to 220/240 °C            227-36233-01                   −
                      1.00 µm         40 to 200/220 °C            227-36234-01               227-36234-02
                      0.25 µm         40 to 200/220 °C            227-36235-01                   −
             0.53 mm  0.50 µm         40 to 200/220 °C            227-36236-01                   −
                      1.00 µm         40 to 200/220 °C            227-36237-01                   −
           * Maximum temperatures listed are for shorter length columns. Longer columns may have a different maximum temperature.




              SH-2330

              Highly polar phase: Crossbond™ 90% biscyanopropyl / 10% cyanopropylphenyl      SH-2330 Structure
             polysiloxane (Non-bonded)
                                                                                      $    /       $    /
              General-purpose columns for cis/trans FAMEs, dioxin isomers.
                                                                                      $)           $)

              Equivalent to USP G8 and G48 phase.
                                                                                      4J  0        4J  0
              Similar phases: DB-23, VF-23ms, SP-2330, SP-2331, SP-2380
                                                                                      $    /


               ID       df             Temp. Range                   30 m                      60 m
                      0.10 µm         0 to 260/275 °C             227-36238-01               227-36238-02
             0.25 mm
                      0.20 µm         0 to 260/275 °C             227-36239-01               227-36239-02
                      0.10 µm         0 to 260/275 °C             227-36240-01               227-36240-02
             0.32 mm
                      0.20 µm         0 to 260/275 °C             227-36241-01               227-36241-02
                      0.10 µm         0 to 260/275 °C                 −                      227-36242-01
             0.53 mm
                      0.20 µm         0 to 260/275 °C             227-36243-01               227-36243-02
           * Maximum temperatures listed are for shorter length columns. Longer columns may have a different maximum temperature.