Page 4 - MUP-3100
P. 4

Stable performance eliminates differences                                                                          Provides Labor Savings and Reduces Downtime

                     between analysts, providing peace of mind
                                                                                                                                        Simply Place the Sample and Reagents in the Instrument to Automatically
                                                                                                                                        Implement Pretreatment

                                                                                                                                        Simply place the prepared reagent
                                                                                                                                        and the culture supernatants or
                                                                                                                                        other samples into the prescribed
                                                                                                                                        place for the instrument and select
                                                                                                                                        pretreatment to implement the
                     Precisely Automated Protocols Eliminate Human Error                                                                process automatically, quickly and
                                                                                                                                        accurately. The MUP-3100 allows for
                                                                                                                                        setting a maximum of 24 samples at
                     Pretreatment is required for LC analysis of profiles for antibody-derived glycans, including purification of the antibodies, glycan   one time and enables processing
                     cut-out, and fluorescent labeling. The MUP-3100 Fully Automated Sample Preparation Module for Glycan Analysis is equipped   twice a day. The MUP-3100 not only
                     with functions to perform dispensing, the addition of reagents, heating, centrifugation, solid phase column extraction, and   lessens the burden on the analyst,
                     sample delivery, thereby automating the entire pretreatment sequence.                                              but also enables pretreatment at
                     Pretreatment of antibody-derived glycans in culture supernatants involves repeated operations including dispensing, the   night or on holidays, thereby
                     addition of reagents, centrifugation, and heating. With solid phase column extraction using an antibody trap carrier, rinsing   accelerating the workflow.
                     must be performed multiple times, which is labor intensive.
                     The MUP-3100 reliably implements pretreatment using the Auto-EZGlyco mAb-N Kit for SHIMADZU protocol. This eliminates
                     human errors, such as forgetting to add the reagent, taking the wrong sample, or omitting a process.
                                                                                                                                        Automatic Confirmation of Consumables Positioning Supports Stable
                                                                                                                                        Operations
                                                Automation of the Entire Process
                                                                                                                                        With the MUP-3100, mistakes are prevented by checking the sample and necessary reagents positioning via image processing prior to
                                                                                                                                        automated operations. The automated protocol will be paused if the sample, reagent, or consumables are missing. Even during
                                                                                                                                        automated operations, pipette tip attachment/detachment and the column grip are monitored by sensors, preventing malfunctions.
                                               Culture solution
                                               (including partially purified samples)


                                                       Addition of sample
                         Antibodies are captured
                          and purified by the
                          solid phase column
                                                                                                                                          Verification of positioning by     Detection of pipette tip       Detection of grip errors
                                                                                                                                              image recognition             attachment/detachment
                                                         Centrifugation
                                                                                                                                        Quality Control Support Functions
                                                Addition of rinsing solution and centrifugation
                                                                                                                                        The control software of the MUP-3100 automatically generates pretreatment results reports and stores them in the database
                                                Addition of reaction accelerating agent and
                          Glycans are released   centrifugation                                                                         along with pretreatment conditions. The MUP-3100 continuously monitors its operating performance, and if the device detects
                          from the antibodies                                                                                           an error, its internal camera automatically creates a video of the 5 seconds before and after the occurrence, which is then saved
                                                Addition of enzyme solution
                                                                                                                                        along with error logs. This assists in identifying the root cause of errors and minimizing downtime.
                                                           Heating                                                                      Abnormal condition                                                Normal condition
                                                                                                                                        Automatically saves a video of the 5 seconds before and after detecting that the tip is   Verify the presence of the tip with
                                                Addition of labeling reagent and centrifugation                                         not installed with a laser.                                       a laser.
                                                Heating
                                                                                                                                            5 seconds                                 5 seconds later
                          Fluorescent labeling
                            of the glycans
                                                 Detachment of antibody trap column
                                                Addition of solvent
                                                Labeled glycans are trapped by the column

                           Recovery of the             Completion of preparation for labeled glycans
                           labeled glycans






        4                                                                                                                                                                                                                                    5
   1   2   3   4   5   6   7   8