Page 5 - Food&Beverage Dioxin in Food
P. 5

Extraction of Samples  Six Steps from the Preparation of Samples,


 SpeedExtractor E-914/E-916   Multi-Sample Extraction, to Multi-Sample Distillation




 The SpeedExtractor is your best solution for fast Pressurized Solvent
 Extraction (PSE). Increase productivity by processing up to 6 samples
 in parallel. Streamline the work ow of your sample preparation with
 easy sample loading and ready-to-use extract collection.

 ■Unrivaled throughput
 ・6 times faster than other PSE instruments thanks to parallel extraction concept   Point
 1
 ・Extract up to 96 samples in an 8 hour shift
 ・Reduce number of replicates due to identical extraction conditions for up to 6   Step1  Step 2
 samples                 Place the samples in the                           Attach the extraction cell to
 ■Ease of operation      extraction cell.                                   the heating block.
 ・Unique design of extraction cells allows for ease of sample loading and cell
 assembly  Point
 ・High level of automation saves time-consuming preparation and increases safety   2
 ・The automated sealing eliminates sources of error and guarantees safety   Point
 ■Low running costs  3
 ・Reduced solvent consumption and minimal need for consumables give lower
 running costs
 ・Save energy and costs with ECO mode for automated heater control




 Point  Parallel work ow for high throughput
 1
 Signi cantly increase throughput with the concerted parallel extraction
 and parallel evaporation. Full compatibility of the SpeedExtractor
 collection glassware with Syncore  Analyst and Multivapor .  Step 4  After the extraction is   Step 3  Close the protective shield and
 ™
 ™
                         completed, remove the                              press the button. Six samples
 Point  Extraction made easy  collection unit.                              (or four samples) are extracted
 2                                                                          automatically.

 The operation of the SpeedExtractor is easy and intuitive. Apply an
 established method at the push of a button and extract simultaneously
 up to 6 samples.







 Point  Automated sealing
 3
 The fail-safe and reliable extraction cells seal automatically using a
 unique sealing principle and guarantee reproducible results.
            Step 5       Transfer the samples from the         Step 6       Multiple  samples are


                         collection vials to the parallel                   simultaneously distilled by the
                         evaporator.                                        parallel evaporator.



 4                                                                                                                   5
   1   2   3   4   5   6   7   8   9   10