Page 12 - Clinical-Medical Physical Properties of Biomaterial
P. 12

Evaluation of Medical Equipment                                                                                           A broad array of materials is used in medical equipment. These include metals for catheters, guide
                                                                                                                                       Mechanical Evaluation of Medical Equipment
     Evaluation of Biological Samples  Medical equipment is classified by the risk of a defect occurring as follows:   ensure the functionality, performance, and safety of their products. The   bandages. They are also used in various environments: some materials are used after sterilization and   Evaluation of Biological Samples
                                                                                                                                      wires, and needles; plastics, films, and other resin materials; and textile materials typified by

                                                                                                                                      other treatments; some are used repeatedly; and others are disposed of after single use. The AGS
                                                                                                                                      Series of Table-Top Precision Universal Testers are all-purpose testers that can be used in a variety of
                                                               assessment of strength properties through physical testing is one such
            general medical equipment including scalpels, scissors, X-ray film, and external
                                                                                                                                      situations, from research and development of such materials to quality control.
                                                               important item.
            diagnostic equipment such as blood analysis equipment; controlled medical
                                                               Evaluation of the mechanical properties of variously shaped medical
            equipment including catheters for the gastrointestinal tract, dental alloys and
            electronic endoscopes; and specially controlled medical equipment including
                                                               equipment requires the use of jigs suited to each piece of equipment. Here,
                                                                                                                                              Left) Jog controller
            orthopedic implants, balloon catheters, contact lenses and stent grafts.
                                                               we will introduce practical testing equipment selected from Shimadzu's
                                                                                                                                                      Control of the crosshead position is at your fingertips.
            Medical equipment manufacturers implement a variety of evaluations to
                                                               diverse portfolio.
                                                                                                                                              Right) Multipurpose tray
                                                                                                                                                        This can be used for a variety of applications, from
                                                                                                                                                                                                                  Autograph AGS Series
                                                                                                                                                        arranging test samples to placing jigs.               Table-Top Precision Universal Tester
             Mechanical Evaluation of Injection Needles and Injectors
            Pharmaceutical manufacturers need to measure the force required when injecting medical liquids from injection needles and injectors.   Tensile Testing of Surgical Tubes
            It is important that the force with which liquid medicine is injected when the plunger moves be maintained within a suitable range. In
     Evaluation of Biomaterials  average test force value and the peak test force at specific positions of plunger displacement. Such values are significantly affected by   tubes (liquid delivery tubes), and injections. Their shape and size vary significantly, and there are dozens   Evaluation of Biomaterials
            tests for this type of evaluation, in addition to collecting data on extrusion force versus time, it is also necessary to measure the
                                                                                                                                      Surgical tubes are used for a variety of surgical procedures and applications including drainage, feed
            the material from which the injector is constructed, as well as sterilization treatments, and the viscosity of the medical liquid.
                                                                                                                                      of connectors and accessories. If a defect occurs, the patient will be put at risk; therefore, determining
                                                                                                                                      the mechanical properties of surgical tubes extremely important. Test requirements involve material
            The Shimadzu EZTest Compact Table-Top Universal Tester and TRAPEZIUM X software are capable of
                                                                                                                                      defects, junction defects, and physiological parameter simulations. To this end, material/final product
            performing such mechanical evaluations quickly and easily.
            Evaluations are possible with respect to injection force, which indicates the force required to start the injection
                                                                                                                                      tensile strength, durability and friction properties are measured.
            of the liquid medicine (i.e. the initial injector press), as well as continuous force, which indicates the force
                                                                                                                                      Regardless of the test application, in order to obtain accurate measurement values, it is important that
            required to maintain an even flow after the medical liquid is extruded from the injector.
                                                                                                                                      tubes themselves, and to evaluations of the connection strength between tubes and accessories.
            Three-Point Bending Testing of Ampoules                                                                                   the tube is suitably gripped. This applies both to the evaluation of the mechanical properties of surgical
                                                                                                                                      Tensile Testing of Catheters
            Injectable drug and medical liquid containers must sterilized and stable with respect to the
     Evaluation of Medical Equipment  the storage of medical liquids, but also on the ease of transportation and handling.            they eliminate bodily fluids, or inject or drip liquid medicines or contrast media. In addition, medical treatments are   Pneumatic flat grips  Extensometer for Soft Samples  Evaluation of Medical Equipment
            drug. Glass ampoules and vials are common, but in recent years, the number of plastic
                                                                                                                                      Catheters are hollow flexible tubes applied for medical purposes. They are inserted into the thoracic cavity, the abdominal
            containers has increased. Their strength properties have a significant effect not only on
                                                                                                                                      cavity and other body cavities, as well as the gastrointestinal tract, urinary duct and other ducts or blood vessels, where
            Ampoule breakage strength is measured by bending tests. Vials are subjected to
                                                                                                                                      performed by passing intravascular enlarging stents and balloons, and embolization coils through catheters.
            compression tests, and vial stoppers are subjected to needle penetration tests. In such
                                                                                                                                      The operability of catheters is significantly affected by their mechanical properties, such as a lack of intra-tubular flexion,
            tests, it is important to use test jigs suited to the sample.
                                                                                                                                      and whether torsion is accurately transmitted in order to change direction via guide wires. Tensile tests are typically
                                                                                                                                      performed, where pneumatic grips are recommended to grip samples accurately. Even samples that become thinner as
                                                                                                                                      tension is applied can be accurately gripped all the way to the breakage point. More accurate measurement values are
                                                                                                                                                                                                                                SES-1000
            Strength Testing of Injection Needles
                                                                                                                                      obtained by using the SES-1000 extensometer for soft samples.
            Several tests are performed to evaluate the mechanical properties of injection needles. In
            elasticity tests, a cantilever force is applied to the needle for one minute to evaluate whether the
            needle returns to the horizontal position. In bending tests, the center of the needle shaft is bent
            90 degrees to examine whether it breaks. In pulling tests, the needle is pulled out from its base.                        Tensile Testing of Bandages and Textile Materials
                                                                                                                                      Bandages function to stop bleeding through compression of wounds, and to absorb blood and pus using highly moisture-absorbent
     Evaluation of Pharmaceuticals and Packaging  Contact lenses are currently used by millions of people. More popular than eyeglasses, they are prescribed to   uniform clamping pressure while preventing the application of unnecessary force.    Evaluation of Pharmaceuticals and Packaging
            The tests must be performed with suitable test jigs, and the EZTest Compact Table-Top Universal
                                                                                                                                      cotton. For this reason, a suitable tensile strength is required, and the bandage must be elastic enough to compress the affected part and
            Tester is recommended for accurate test force measurements and deflection measurements.
                                                                                                                                      to hold other medical instruments in place.
                                                                                                                                      Individual fibers can be tested at constant test conditions by using capstan type grips (also used for tensile tests of hair) to maintain a
             Evaluating the Mechanical Properties of Contact Lenses
                                                                                                                                      Tensile Testing of Silicon Rubber and Other Soft Materials
            correct a variety of vision problems, and are manufactured in a variety of styles ranging from hard to soft lenses.
            Contact lenses must withstand repeated daily usage, so suitable strength is required. For this reason, tensile and
                                                                                                                                      In the therapeutic arena, a variety of rubber products and thin resin materials such as
            compression tests are performed.
                                                                                                                                      silicon rubber are widely used. The TRViewX Video Type Non-Contact Extensometer is
            Soft contact lens material slips easily, is delicate, and is damaged by very small forces. When performing contact
            lens tensile tests, the sample grip method and the limited grip area can cause problems. When testing in air, the
                                                                                                                                      samples. Since extension is measured without contact, displacement is measured
                                                                                                                                      accurately all the way to the breakage point, without being subjected to unnecessary
            material may dry and crack, so contact lens tests are performed in environments simulating physiological
                                                                                                                                                                                                                             TRViewX
            conditions.                                                                                                               optimal for accurate extension measurements in tensile tests of soft stretchable   Video Type Non-Contact Extensometer
                                                                                                                                      loads. Measurements of displacement in the width direction are also possible.
                                                                                                                                                                                                                 Physical Property Testing Equipment
                                                                                                                                                                                                              for Biomaterials and Medical Applications
      12                                                                                                                                                                                                                    Solutions for Biomedical Testing  13
   7   8   9   10   11   12   13   14   15   16