Page 8 - Shimadzu UV-3600 Plus
P. 8

Extensive Selection of Application Programs                                                                                                   Electrical, Electronics, and Optics

                     for a Wide Variety of Applications                                                                                 Transmittance Measurement of Lenses


                                                                                                                                        Imaging devices, such as mobile phones, digital cameras, and security cameras, are all equipped with lenses. The transmittance of
                                                                                                                                        a lens is one factor that determines lens performance. However, because the lens itself focuses light, it is an especially difficult
                     Electrical, Electronics, and Optics                                                                                type of sample to measure accurately.
                     High-absorbance measurement of polarizing films                                                                          Because of the focal capability of lenses, the total light passing through the spectrophotometer during the measurement of
                     Reflection measurement of multilayer films                                                                           the baseline can be different than after passing through the lens during measurement due to refraction. In such cases, the use of
                                                                                                                                        an integrating sphere can be used to collect all the light passing through the lens and provide for more accurate measurements.
                     Absolute reflectance measurement of highly reflective mirrors
                                                                                                                                        In addition, using the transmission-type integrating sphere included with the BIS-603 can reduce measurement errors.
                     Spectral characteristic measurement of beam splitters                                                                   Using an MPC-603A multipurpose large sample compartment with an optional V-stage enables transmittance measurements
                     Relative emission measurement of LEDs                                                                              for various size and length lenses.
                     Transmittance measurement of quartz plates                                                                              The MPC-603A and BIS-603 are an ideal combination for measuring lenses.
                     Absolute reflectance measurement of anti-reflection coatings
                                                                                                                                                                                         Measurement of lens by  Measurement of lens by
                     Transmittance measurement of functional films                                                                                                                      4-hole type of integrating sphere  transmission-type integrating sphere
                     Diffuse reflectance measurement and band gap measurement of semiconductor materials
                     Transmittance measurement of solar cell cover glass, etc.
                                                                                                                                                                                       reference
                     Construction                                                                                                                                                                   lens                   lens

                     Transmittance measurement of window glass and window glass films
                                                                                                                                                                                    There may be a measurement error caused by  There may no measurement error because
                     Reflectance measurement of paints and building materials                                                                                                        reflectance differences between the reference  of the same reflectance in internal surface
                                                                                                                                                                                     and internal surface of integrating sphere.  of integrating sphere.
                     Transportation Equipment

                     LiDAR collision avoidance sensor evaluation system

                     Pharmaceuticals, Cosmetics, and Life Sciences
                     Cosmetic color measurement and ultraviolet screening measurement                                                                              Electrical, Electronics, and Optics
                     Measurement of drugs containing crystallization water
                     Measurement of moisture in plants                                                                                  Transmittance Measurement of Very Small Samples
                     Measurement of various amino acids                                                                                 The current miniaturization of various products, such as sensors,
                     Quantitation of proteins and nucleic acids                                                                         means that the measurement of very small samples is now required.
                                                                                                                                        The figure shows the results of a transmission spectrum measurement
                     Near-infrared measurement of pharmaceutical components
                                                                                                                                        on a micro-sensor window.
                                                                                                                                             When measuring very small samples, the light beam must be
                     Chemicals                                                                                                          adjusted to the sample size. Therefore, by using the UV-3600i Plus in
                     Transmittance and color measurements of plastic materials                                                          combination with an optional MPC-603A multipurpose large sample
                     Reflectance measurement of silica-based white powered materials                                                     compartment, small beam aperture unit (P/N 206-22051-41), and
                                                                                                                                        small sample holder (P/N 206-28055-41), the optical system can be
                     Thickness measurement of thin films
                                                                                                                                        configured to enable measurement of even micro areas by focusing
                     Near-infrared measurement of organic solvents                                                                      the beam down to diameters as small as  2 mmø.
                     Haze measurement of plastics                                                                                            The MPC-603A is a UV-3600i Plus option that enables the
                                                                                                                                        measurement of various samples ranging from small large.
                     Foods
                     Diffuse reflectance measurement of wheat flour                                                                        Options Used for Measurements
                     Quantitation of vitamins, food additives, and minerals
                     Quantitation of phenol elution in containers and packaging materials                                               MPC-603A Multi-Purpose        Micro Beam Lens Unit    Micro Sample Holder    Others
                                                                                                                                        Large-Sample Compartment                                                    ・ V stage
                     Textiles                                                                                                                                                                                       ・ BIS-603 Sample
                                                                                                                                                                                                                        Base Plate
                     Transmittance and reflectance measurements and ultraviolet screening measurement of textiles                                                                                                        Integrating
                     Color measurement of textiles                                                                                                                                                                      Sphere Set





        8                                                                                                                                                                                                                                    9
   3   4   5   6   7   8   9   10   11   12   13