Page 8 - Shimadzu TOC-V Series
P. 8
S Model with Screen and Keyboard or P Model Under PC Control
Select the Model that Suits Your Application
Supports FDA 21 CFR Part 11 Compliance S Models
Combining TOC-Control V, which offers security and operation log features, with Shimadzu's
CLASS-Agent data management tool, provides full support for complying with FDA 21 CFR Part 11 requirements. TOC-VWS The combination of simple, easily operated keyboard and large LCD makes these
models easy to use.
User Authentication Link with CLASS-Agent Software
A user ID and password are used to prevent unauthorized Measurement data from TOC-Control V can be output to
access. Access rights can be specified for individual users. CLASS-Agent databases for integral management with data
from other instruments.
A separate window for each measurement Helpful operation guides are displayed.
condition setting item enhances clarity and ease of
input.
Operation Log
The software can maintain a record of all operations, which Recommended PC Specifications
allows tracking the history of instrument operating status and Models DOS / V Compatible Models
any changes to settings. OS Windows 7 Professional ( 32 bit version )
Windows Vista Business ( 32 bit version )
Windows XP Professional ( 32 bit version )
CPU 2 GHz min. ( Windows 7, Windows Vista )
1.5 GHz min. ( Windows XP )
Main memory 2 GHz min. ( Windows 7, Windows Vista )
1 GHz min. ( Windows XP )
Hard Disc 40 GB min.
Monitor XGA ( 1024 × 768 cot ) min.
Frequently used functions such as calibration, The method function registers measurement
CD-R Drive
Other
RS-232C Connector measurement, and ASI measurement are assigned conditions.
*PC and monitor must be purchased separately. dedicated keys to reduce operations.
Features (Common to S and P Models)
Automatic setting of optimal measurement Automatic selection of the best calibration curve Automatic exclusion of anomalous values and Comprehensive calibration system handles many
conditions Up to three calibration curves can be set for sample re-calculation of repeated analyses uses
When creating the calibration curve, the optimal measurement measurement. The optimal calibration curve is selected for the The mean value, standard deviation, and coefficient of variation Output is linearized for the entire range.
conditions are displayed when the standard solution sample and the sample measurements are conducted using are displayed and printed during repeated analyses. Anomalous Calibration curve can be created to compensate for TC in
concentration is set. Detailed calibration curve information can these measurement conditions. values can be automatically eliminated and re-calculated. water used for standard solution adjustment.
easily be referenced when setting the measurement conditions. A maximum of 25 (model S; model P has no limit) calibration
Convenient automatic power off function curves can be stored and recalled. All calibration curve data
Automatic condition changing and Automatic power off after the electric furnace cools down can be displayed and recorded.
re-analysis of out-of-range samples ensures power is not left on and saves energy.
If the sample peak goes over the calibration curve range,
measurement conditions such as dilution rate and injection
volume are automatically changed and the analysis is repeated.
TOC-V Series
8 Wet Oxidation TOC Analyzer 9