Page 10 - Shimadzu TOC-V Series
P. 10

Extensive Options Expand Functionality                                                                                    Specifications





            Autosampler                                                                                                               Total Organic Carbon Analyzer TOC-V Series         Autosampler ASI-V


            ASI-V    Even More Functionality and Convenience,                                                                                                 Wet oxidation Total Organic  Vial types        Select from two types:40 mL,125 mL
                     Enabling Samples to Be Added During Continuous Measurement                                                                                  Carbon Analyzer          Number of Vials    40 mL : 68
                                                                                                                                                                                                             125 mL : 24
            Features                                                                                                                   Model                TOC-VWP         TOC-VWS       Vial septum        with dedicated septum
              Select from two vial types with different capacities to suit your application.                                           Measurement method    Wet oxidation/NDIR detection  Sample sparging   OK
             ・40 mL vials × 68  ・125 mL vials × 24                                                                                     Operation method    PC-controlled   Standalone     Dimensions WxDxH(mm)  W370 × D540 × H490 (excluding protrusions)
              All vial types have a well sealed septum that can be easily replaced with the screw                                      Measured items             TC,IC,TOC,NPOC          Weight             Approx. 14 kg
              cap.
              Changing analysis conditions or adding sample vials during analysis is simple. System                                    Applicable samples        Aqueous sample          8-Port sampler OCT-1
              operation and carrier gas flow can be automatically stopped on completion of   Combining the ASI-V automatic sample injector  Measurement range      TC:0 to 3,500
                                                                                                                                       (mg/L)
              measurements.                                                     with a TOC-V Series analyzer                                                        IC:0 to 3,500         Number of OCT-1 Connection  Up to 2 OCT-1 units
              Creating multiple calibration curves and selecting the optimal curves for samples   creates a fully automatic analysis system.  Detection limit       0.5µg/L               Vial types         Any sample container can be used
              with significantly differing concentrations allows these samples to be analyzed in a                                     Measurement                CV 1.5% max.                               8 OCT-1
                                                                                                                                       accuracy
              single run.                                                                                                              (reproducibility)   (CV 2% max.at 100 mg/L or higher)  Number of  Vials   16 for dual OCT-1
                                                                                                                                                                                                              (Sparging is done in the syringe of TOC-V)
            8-Port sampler                                                                                                             Measuring time            TC:Approx. 4 min         Sample spurging    No sparging with OCT-1
                                                                                                                                                                 IC:Approx. 4 min         Dimensions (mm)    W245 × D245 × H440 (excluding protrusions)
            OCT-1 The Bridge to Ultra-Simplified Automatic Measurement                                                                                                                    Weight             Approx. 3.5 kg
                                                                                                                                       Sample injection         Automatic injection
            Features                                                                                                                   Sample injection          350 to 20,400 µL        Solid Sample Combustion
                                                                                                                                       volume                       variable
              Easy-to-use autosampler does not require special vials.                                                                                                                    Unit SSM-5000A
                                                                                                                                                                 Automatic internal
              Up to 8 samples can be measured with a single OCT-1 unit.                                                                IC pre-treatment       acidification and sparging
              Up to 16 samples can be measured by adding a second OCT-1.                                                               Automatic dilution       Dilution factor 2 to 50                      TC:Catalytically aided combustion oxidation at 900°C.
              Commercially available stirrers can be used. (Stirrers are sold separately.)                                             Carrier gas              High purity nitrogen      Method             IC:Pre-acidification, oven temperature: 200°C.
              Samples can be added during continuous measurement.                                                                                                                         Measured Item      TC,IC,TOC
                                                                                                                                       Gas pressure                 300 kPa
            * Select either ASI-V or OCT-1. They cannot be used simultaneously.
                                                                                                                                                               Approx. 3,000 L/month                         TC:0.1 to 30 mg carbon
                                                                                                                                       Gas consumption                                    Measuring Range*    (1~20 g carbon in high sensitivity measurement)
                                                                                                                                                        (operating conditions: 8 hours/day × 5 days/week)    IC:0.1 to 20 mg carbon
            Solid Sample Combustion Unit                                                                                               Operating keys        Use PC         Built-in      Sample Amount*     1gram-aqueous content < 0.5 g
                                                                                                                                       Display               Use PC        Built-in LCD   Analysis Time*     5 to 6 minutes at a gas rate
            SSM-5000A Capable of TOC Measurements in Solid Samples                                                                     Printer              PC printer      Built-in                         99.9% O2 at the 500 mL/min.
                                                                                                                                       Ambient temperature range    5 to 35°C             Carrier Gas        High-purity O2 Gas is required for high
            Features                                                                                                                                                                                         sensitivity measurement.
                                                                                                                                       Power supply         AC100~127 V±10%, MAX350 VA
              Measurement of maximum 1 g samples with up to 30 mg carbon content reduces                                                                    AC220~240 V±10%, MAX350 VA
              weighing errors, and errors due to uneven distribution of the sample carbon                                              Dimensions (mm)  W440 × D560 × H460 (excluding protrusions)  Power Requirement  100~127 V or
                                                                                                                                                                                                             220~240 V as ordered.
              content.                                                                                                                 Weight                     Approx. 40 kg                              700 VA, 50/60 Hz
              A single TOC analyzer unit can handle a range from several 10 ppb TOC in ultrapure                                                                                          Dimensions WxDxH(mm)  W450 × D656 × H290
              water to several 10% TOC in solid samples.                                                                                                                                  Weight             Approx. 30 kg
              Measurement of inorganic carbon (carbonate) in solid samples.     In addition to aqueous samples, carbon                                                                   *Will vary with sample type and measurement condition.
              Measurement of aqueous samples containing large quantities of suspended   measurements can also be performed on soil,
              substances.                                                       sludge, sedimentation, and other solid samples.
                                                                                By swabbing, the carbon in attached residues
              Simply change the onscreen settings to switch between aqueous sample   can be measured for cleaning validation.
              measurement with the TOC-V, and solid sample measurement using the SSM-5000A.

              【GMP Cleaning Validation Using the Swab Method】
                                Swab sampling       Transfer to sample boat             TC measurement







                                              Residue evaluation using swab sampling with quartz microfiber filter paper and direct combustion carbon analysis
                                                                  (Please contact your local Shimadzu representative for further information.)

                                                                                                                                                                                                                         TOC-V Series