Page 7 - Shimadzu Tm Analysis System
P. 7

For more details, access here.
 Efficient Automated Workflow

                                      •  Automated support functions utilizing digital technologies, such as M2M, IoT, and
                                        Artificial Intelligence (AI), that enable higher productivity and maximum reliability.
 Conventional Tm analysis requires multiple steps, including checking the UV-Vis spectrum, annealing,
                                      •  Allows a system to monitor and diagnose itself, handle any issues during data acquisition
 measuring the melting curve, and analyzing data, with recording and data management performed separately.
                                        without user input, and automatically behave as if it were operated by an expert.
 In contrast, LabSolutions UV-Vis Tm achieves a seamless workflow and efficient Tm analysis by performing
                                      •  Supports the acquisition of high-quality, reproducible data regardless of an operator’s
 time-consuming annealing, correction (background wavelength and temperature blank correction),   skill level for both routine and demanding applications.
 and Tm value calculation (average or derivative methods) steps automatically.



 Check data by         Easy setting                                 Retains a record of
 NEW  switching     configuration and                                 everything from
 between tabs       automatic analysis                                measurement
                                                                        to analysis





 Tm Analysis System








 Melting Curve       Tm Analysis Settings

                                                                       Application log
                                                                                               LOG
                                                                      (LabSolutions DB)








 UV-Vis Spectra  Temperature Program Settings
                                                                                      Tm Value
 One Step  Analysis








 Measure spectrum  Anneal  Measure Tm values and analyze data              Calculate Tm values



 D
 A
 B C D
 A
 B C
                        records prevents Tm value reproducibility
 be entered manually each time
 transition from spectral
 measurement to annealing/melting
 Our  conventional  method  Risk of switching samples during   measurement  curve measurement  Annealing temperature must   Lack of analysis process/parameter   Tm Value  Tm Value
 No record of annealing
 Spectral
 Annealing/melting
 curve measurement steps
 execution is retained
 steps
 steps
 Tedious data management because
 spectral and melting curve
 temperature is retained
 data are managed separately  No record of annealing                    Analysis results can vary depending
                                                                        on the analyst
 6                                                                                                                 7
   2   3   4   5   6   7   8