Page 4 - Shimadzu SALD-7500nano
P. 4

Features of SALD-7500nano






               Single detection face continuously captures forward-scattered light up to a 60° angle                                     Laser diffraction method ISO 13320 and JIS Z 8825-1 compliant


                                                               The target particle size range is seamlessly covered using a single    Tke SALD-7500nano complies with ISO 13320 and JIS Z 8825-1 laser diffraction and scattering standards.
                 Side / back scattered                         measurement principle, single optical system, and single light
                 light sensor
                                 60°                           source. Additionally, because the SALD-7500nano does not
                                                               incorporate multiple optical systems that create discontinuities in
                                                               the data, accurate particle size distribution measurements are            Validation possible with JIS standard particles
                                                               possible across the entire measurement range using a single
                                                               standard. The application of the SLIT* optical system, based on
                 semiconductor laser        Wing sensor ll                                                                            System performances can be confirmed using a MBP1-10 standard particle specified in JIS Z 8900-1. These samples have a broad particle
                                  Wing sensor ll               sophisticated scattered light intensity tracing technology, smashes
                           Cell                                conventional wisdom to continuously capture forward-scattered          size distribution, which is specified by the JIS standard. Using these samples allows verifying that the instrument is always accurate.
                          Condenser lens                       light at up to a wide 60° angle on a single detector face. This
                                                               achieves high resolution in the fine particle region.
                               SLIT optical system                                           *SLIT (Scattered Light Intensity Trace)
                                                                                                                                         Allows verifying the validity of measurement results by referencing light intensity distribution data

               High-Resolution/High-Sensitivity Wing Sensor ll
                                                                                                                                      Since light intensity distribution data (raw data) and
                                                                                                                                      measurement results (particle size distribution data) can be
            High-Resolution/High-Sensitivity Wing Sensor ll                                                                           displayed on the same screen, measurement results can be
            forward diffracted/scattered light is detected by a “wing sensor ll”,                                                     verified while viewing both data sets. This allows users to verify
            a 78-element sensor developed using semiconductor                                                                         whether the detection signal level (particle concentration) is
            manufacturing technology of the highest level.                                                                            appropriate, and to confirm the validity of measurement results
            This sensor can detect greatly fluctuating small-angle forward                                                            from multiple aspects, such as in terms of the distribution width
            scattering light with a high level of resolution and wide-angle                                                           and the presence of aggregates and contaminants.
            scattering light of a low optical intensity with a high level of
            sensitivity. Also, side scattered light is detected by 1 sensor
            element and back scattered light is detected by 5 sensor
            elements. Accurately capturing light intensity distribution
            patterns with a total of 84 sensor elements enables the
            high-resolution, high-precision measurement of particle size
            distributions over a wide particle diameter range.
                                                                                                                                         Wide application applicability

               More Stable Optical System                                                                                             The system configuration can be optimized to address various uses, purposes, measurement objects, environments and conditions.


            The Omnidirectional Shock Absorption Frame (OSAF) fully isolates all elements of the optical system from shocks and vibrations.                                           SALD-MS75           Wet measurement system
                                                                                                                                                                                      Multifunction
            This eliminates concerns about adjusting the optical axis.                                                                                                                Sampler Unit        *The standard model for dispersion
                                                                                                                                                                                                            measurement in liquids.
                                                                                                                                                                                                          *Strong circulation power can
                                                                                                                                                                                                            circulate high density particles up
                                                                                                                                                                                                            to 800 um
                                                                                                                                                                                                          *Ultrasonic sonicator is included as standard.
               Built-in Self-Diagnostic Functions Ensure Easy Maintenance
                                                                                                                                                                   SALD-7500nano
                                                                                                                                                  WingSALD ll  Measurement Unit (Optical System)  SALD-BC75
            These analyzers incorporate powerful self-diagnostic functions.                                                                         PC Set                            Batch Cell          Small-Volume Measurement System
                                                                                                                                                                                                          *Small volume of 5 mL can be selected,
            The output signals sent by the sensors and detecting elements                                                                                                                                 *Organic solvent or acid can be used
                                                                                                                                                                                                            as a dispersion medium.
            and the instrument operating status can be checked, facilitating                                                                                                                              *Stirring functions for suppressing particle
            easier maintenance. Using the Operation Log function, detailed                                                                                                                                  precipitation controlled by PC is available.
            information about, for example, the instrument usage status and
            contamination of the cells is included with all the measurement
            data, making it is possible to investigate the validity of                                                                                                                SALD-HC75           High-Concentration Measurement System
            measurement data obtained in the past.                                                                                                                                    High-concentration  * Undiluted high-concentration samples
                                                                                                                                                                                      Measurement            up to 20 wt% sandwiched between
                                                                                                                                                                                      Unit                   glass slides can be measured directly.
                                                                                                                                                                                                          Ultra Small-Volume Measurement System
                                                                                                                                                                                                          * Optical special glass slides with an
                                                                                                                                                                                                             indentation permit measurements down
                                                                                                                                                                                                             to 15-microliter samples.
                                                                                                                                                                                                                     SALD-7500nano
      4                                                                                                                                                                                                                      Nano Particle Size Analyzer  5