Page 3 - Shimadzu SALD-7500nano
P. 3

High-sensitivity Measurement of   Wide Measurement Range: 7 nm to 800 µm
                    From primary particles to sub-visible particles and contaminants
 Nano Particle Size Distribution

                      Changes in particle size across the 7 nm to 800 µm measurement range can be continuously measured using a
 A powerful new tool for research and development in nanotechnology     single light source, single optical system and single measurement principle.
 and life sciences, and for measuring fine bubbles.        Since a primary particle and an aggregate and contaminant can be measured with one system,
                      the aggregation properties by a dispersion condition can be checked.
                                                   Primary particle size
 Evaluation of the dispersion and aggregation characteristics of particles is realized with a wide   Primary particle size  Primary particle size
 measurement range and in real time.                               The evaluation of the dispersion and aggregation
                                                                   characteristics of the particles is realized with a
 The SALD-7500nano was developed to provide accurate and high-sensitivity   wide measurement range and in real time.
 measurement of low concentration or high-light absorption nano particles. It achieves sensitivity in the nano
 area about ten times higher as compared to conventional instruments. In addition, low concentration samples   Particle size
 of less than 1 ppm can be measured.   Particle size  Particle size

 Enables measurement of fine bubbles (micro bubbles from 100 nm to 60 µm), and allows real-time tracing of
 the changes in the bubble diameter.  1-Second Minimum Serial Measurement Time. Real time monitoring

 This system enables the evaluation of sub-visible particles included in biopharmaceuticals.        By incorporating a single light source, which does not require switching, and the wide-angle detection method,
 Special options can be added to create an aggregation analysis for biopharmaceuticals.     the measurement time can be reduced to a minimum of 1 second. In addition, the particle size distribution can be
                      displayed in real time at 1-second intervals.
                      Serial observations of the dispersion, cohesion or dissolution reaction processes are possible at 1-second intervals, and these
                      results can be saved. Functions for statistical processing and 3D display of the particle reaction processes offer multifaceted
                      analyses and evaluations.
                        Connecting the flow cell directly to the fine bubble generator enables in-line real-time monitoring of the changes in
                      fine bubbles.
                                Measurement unit  Wing sensor II
                      Drain  Pump            Flow cell
                                     Side scattered
                                     light sensor
                                                                         Nomalized Particle Amount
                                Laser light source
                                   Backward scattered  Condensing lens
                                       light sensor
                                        Fine bubble generator
                                                                                   Particle Diameter
                                                                           In-line real time monitoring of
                                        Water supply
                                                                           the change in a fine bubble

                    Measure Concentrations from 0.1 ppm to 20 %


                        Compared to other instruments, the SALD-7500nano permits measurements across an extremely broad
                      concentration range of 0.1 ppm to 20 %.
                      The particle size of fine particles, particularly nano particles, varies with the concentration.
                      The dispersion and coagulation of nano particles can be observed while altering the concentration.
                        Accurate analysis of samples in which the particle size distribution changes with dilution is possible, as
                     measurements can be conducted on the undiluted solution or after minimal dilution. For example, commercial
                      hand creams, face creams, and rinses can be measured with hardly any pretreatment.

                    Measurement of Small Sample Amounts


 Nano Particle Size Analyzer       Drainage of a small quantity of a suspension liquid is adequate since the SALD-BC75 batch cell permits analysis of a
 SALD-7500nano        volume of just 5 cm . Most organic solvents can be used.
                                   3
                        A combination of the SALD-HC75 high-concentration measurement unit with special glass slides featuring
                      a  shallow indentation permits measurement on just 15 micro liters.