Page 15 - Shimadzu SALD-2300
P. 15

System Structure



 Powder samples can be measured without preparation.
 Cyclone Injection Type Dry Measurement Unit SALD-DS5S


 A cyclone type sample suction mechanism has been developed.  Measurement Results
 Strong double dispersion process of suction and injection can be used.  Q3(%)  q3(%)  Hard flour  Dispersion of flour by water is so difficult that organic
 Measurement with high precision, high sensitivity, high reproducibility and high resolution  20  Soft flour  solutions such as IPA must be used for wet

 ■Sample to be applied  80                           15                   measurement.
 ・  Easily dissolved samples (medicine, powder foods)  Normalized Particle Amount (Diff) 100 60  Cyclone injection mechanism can disperse flour in air
 ・  Easily agglomerated samples (magnetized particles)  40  10 Normalized Particle Amount (Diff)  easily, enabling dry measurement with good
 ■Features                                           5                    reproducibility.
 ・  Using three types of sample suction mechanism (cyclone type, one shot type, hand shot type) and four types of dispersion nozzle, the optimum combination   20  Moreover, the sample can be gathered into a vacuum
 can be selected to perform measurements based on the sample properties and amount.  0  0
               0.01  0.05 0.1  0.5  1  5  10  50  100  500 1000  5000     cleaner and disposed of easily.
 ・  When the cyclone type is used, the sample loaded in the special sample holder is sucked in while being rotated, then injected from the nozzle and measured.  Particle Diameter (µm)
 In addition, since a sample holder is used, there is no scattering of the sample nor do the operator's hands become soiled.
 ・  When the one shot type is used, putting the sample into a small hopper is the only operation required for measuring. This type is suitable for a small sample   Q3(%)  q3(%)  Q3(%)  q3(%)
 amount. (option)                                    10                                                 10
 ・  When the hand shot type is used, the sample can be sucked directly from the beaker or chartula for measurement. (option)   80  8  80  8

 Sample Suction  Normalized Particle Amount (Diff) 100 60  6 Normalized Particle Amount (Diff)  Normalized Particle Amount (Diff) 100 60  6 Normalized Particle Amount (Diff)
 Mechanism    40                                     4           40                                     4
 One Shot Type (option)  20                          2           20                                     2
 Measurement Unit
 Hopper        0 0.01  0.05 0.1  0.5  1  5  10  50  100  500 1000  5000 0  0 0.01  0.05 0.1  0.5  1  5  10  50  100  500 1000  5000 0
 Wing Sensor                  Particle Diameter (µm)                             Particle Diameter (µm)
 Ejector  Sensor for Forward Scattered Light       2 types of gastrointestinal medicines
 Air Inlet to Prevent Backflow
 Scattered Light  Dissolubility depends on particle size distribution and may adversely impact the measurement of pharmaceuticals. Dry measurement is
 Hand Shot Type (option)  4 Types  Condensing Lens  necessary to measure pharmaceuticals with dissolution effects.
 Suction Tube  Ejector  Injection Nozzle  Sample Particles

 Injection  Suction
 Laser Beam
 Hand Switch  Air Valve  PC
 Sample can be injected
 Suction Nozzle
 only under the operation
 of a vacuum cleaner  Pressure Sensor to
 Confirm the Operation
 Cyclone Type
 Pressure Regulator  of Dust Collector  Dust
 (PC Control)  Collector
 Compressor
 (Compressed Air
 Source)



 ・ When compressed air, including the sample, flows through the injection nozzle, the shape,
 area, and direction of the cross section is changed in order to obtain the large changes in
 volume, pressure and direction of air flow. Therefore, agglomerates can be strongly
 dispersed into air.
 ・  In order to obtain the optimum dispersion based on the properties of the sample one of
 Standard dispersion nozzle (Type 1)  Sample  four differently shaped nozzles can be selected.
 Section-2  Injection  ・  Magnetized particles, which are easy to cohere in liquid, can be strongly dispersed into
 Section-1  Section-4
 Section-3  air using the type 1 injection nozzle. Therefore, accurate measurement results can be
 3 mm dispersion nozzle (Type 2 * ) 1  obtained.
 Section-2  ・  Using a type 4 dispersion nozzle the dispersion force is weakened, enabling measurements
 Section-1  Section-4
 Section-3  to be made without destroying fragile particles.
 2.5 mm dispersion nozzle (Type 3 * ) 1  ・  Using type 2 and 3 dispersion nozzles the dispersion force is strengthen, that is suitable
 Section-2  for the dispersion of fine particles.
 Section-1  Section-4
 Section-3  ・  When the cyclone type is used, the double dispersion process of suction and injection
 Straight nozzle (Type 4 * ) 2  enables measurement with good reproducibility.
 Section-2  Section-4
 Section-1  Section-3  *  Type 2 and Type 3 are set options   *  Type 4 is an option              SALD-2300
 2
 1
 14                                                                                             Laser Diffraction Particle Size Analyzer  15
   10   11   12   13   14   15   16   17   18   19   20