Page 11 - Shimadzu SALD-2300
P. 11

High efficiency  Processes multiple sets of data more efficiently  System Structure



 Multiple sets of data can be stored as a group, which enables easier organization, re-displaying, and reanalysis of data. Data can be loaded as a   Wide range of system configurations can be designed by adding optional units.
 group and displayed or analyzed at the same time, rather than having to load each set separately.



                                                              or more
                                                                                  or more
 High analysis capability  Measurement data from multiple facets  100mm  680mm    100mm  about 400mm
 –Extensive assortment of data analysis applications included standard
                                                           100mm  or more  Measurement Unit
                                                                       SALD-2300
 The following data analysis applications are included standard.                       PC
                                                             320mm  280mm
 ■ Evaluation of Scattering Angle
 Graphs the components of scattered light intensity at each angle. This takes advantage of the features of the highly-integrated   Measurement Unit SALD-2300
 photodiode array to allow evaluating the low-angle scattered light with high resolution.  The batch cell and the high-concentration sample  1280mm or more
              measurement system can be set in the measurement unit.
 Application Fields: Evaluating the scattering characteristics of films and sheets.  Small-Volume Measurement System
                     (SALD-2300 and SALD-BC23)
                High-Concentration Sample Measurement System
 ■ Data Emulation Function  (SALD-2300 and SALD-HC23S)
                  Very Small-Volume Measurement System
 Based on SALD series measurement results, this function allows emulating measurement results obtained using other models or other   (SALD-2300 and SALD-HC23S and
                    “Glass Slides with Indentation”)        100mm                    100mm
 measurement principles. This maintains compatibility with data results obtained with previous measurement methods.  or more  820mm or more  or more  about 400mm or more
                                                        100mm  or more  SALD-2300
 Cumulative %  Emulation by 51 conversion expressions                 Measurement Unit      PC
 51 conversion expressions can be obtained at the cumulative % points   640mm or more
 (0.01%, 2%, 4% …… 96%, 98%, 99,98% on vertical axis) to express the   540mm
 SALD Series
 particle size  relationship between the particle size distribution data measured by
 distribution data  Particle size
 51 points  distribution data using  SALD-2300 and that measured by another instrument or technology.  SALD-MS23
                     Wet Measurement System
 a different analyzer
 model/measurement  102 parameters ai (i = 1,2,..…, 51) and bi(i = 1,2,..…, 51) used in 51   (SALD-2300 and SALD-MS23)  Sampler
 principle  conversion expressions can be stored as a parameter table, which can be   1420mm or more
 used for emulations.
                                                                                    130mm
 This emulation function may be able to reduce some problems when an     680mm            about 400mm
 Particle size
 old particle size analyzer is upgraded to a new instrument.  100mm  or more  Measurement Unit
                                                                   SALD-2300
                                                                                           PC
                                                       750mm or more  650mm
 The same samples must be measured by two instruments in order to
 develop the parameter table for emulations.

                                                                                   SALD-DS5S
                                                                                  (Pressure regulator)
                     Dry Measurement System
                                                                                      SALD-DS5S
                    (SALD-2300 and SALD-DS5S)                                   (Sampling unit and dispersion device)
                                                                              1210mm or more

                                                              100mm                    130mm
 ■ Mixture Data Simulation Function                           or more      820mm             about 400mm
 Allows simulating particle size distributions using any mixture ratio of multiple particle size distributions. This makes it possible to   100mm  or more  SALD-2300
 determine the optimal mixture ratio for obtaining the desired particle size distribution, without repeatedly measuring the particle size   Measurement Unit  PC
 distribution of sample mixtures.
                                                    750mm or more
 ■ Data Connecting Function                              650mm
 Allows combining the measurement results for two different measurement ranges at any particle size point to create a single particle size   Wet/Dry Measurement Full System  SALD-DS5S
 distribution. For example, sieve data for particles above 2000 µm can be combined with SALD series data for particles below 2000 µm to   (SALD-2300 and SALD-MS23 and SALD-DS5S)  SALD-MS23  (Pressure regulator)
                                                              Sampler
                                                                                         SALD-DS5S
 create a wide-ranging particle size distribution, which is required for civil engineering, disaster prevention, and environmental fields.  (Sampling unit and dispersion device)
                                                                              1450mm or more

                                                                                                 SALD-2300
 10                                                                                            Laser Diffraction Particle Size Analyzer  11
   6   7   8   9   10   11   12   13   14   15   16