Page 11 - Shimadzu SALD-2300
P. 11
High efficiency Processes multiple sets of data more efficiently System Structure
Multiple sets of data can be stored as a group, which enables easier organization, re-displaying, and reanalysis of data. Data can be loaded as a Wide range of system configurations can be designed by adding optional units.
group and displayed or analyzed at the same time, rather than having to load each set separately.
or more
or more
High analysis capability Measurement data from multiple facets 100mm 680mm 100mm about 400mm
–Extensive assortment of data analysis applications included standard
100mm or more Measurement Unit
SALD-2300
The following data analysis applications are included standard. PC
320mm 280mm
■ Evaluation of Scattering Angle
Graphs the components of scattered light intensity at each angle. This takes advantage of the features of the highly-integrated Measurement Unit SALD-2300
photodiode array to allow evaluating the low-angle scattered light with high resolution. The batch cell and the high-concentration sample 1280mm or more
measurement system can be set in the measurement unit.
Application Fields: Evaluating the scattering characteristics of films and sheets. Small-Volume Measurement System
(SALD-2300 and SALD-BC23)
High-Concentration Sample Measurement System
■ Data Emulation Function (SALD-2300 and SALD-HC23S)
Very Small-Volume Measurement System
Based on SALD series measurement results, this function allows emulating measurement results obtained using other models or other (SALD-2300 and SALD-HC23S and
“Glass Slides with Indentation”) 100mm 100mm
measurement principles. This maintains compatibility with data results obtained with previous measurement methods. or more 820mm or more or more about 400mm or more
100mm or more SALD-2300
Cumulative % Emulation by 51 conversion expressions Measurement Unit PC
51 conversion expressions can be obtained at the cumulative % points 640mm or more
(0.01%, 2%, 4% …… 96%, 98%, 99,98% on vertical axis) to express the 540mm
SALD Series
particle size relationship between the particle size distribution data measured by
distribution data Particle size
51 points distribution data using SALD-2300 and that measured by another instrument or technology. SALD-MS23
Wet Measurement System
a different analyzer
model/measurement 102 parameters ai (i = 1,2,..…, 51) and bi(i = 1,2,..…, 51) used in 51 (SALD-2300 and SALD-MS23) Sampler
principle conversion expressions can be stored as a parameter table, which can be 1420mm or more
used for emulations.
130mm
This emulation function may be able to reduce some problems when an 680mm about 400mm
Particle size
old particle size analyzer is upgraded to a new instrument. 100mm or more Measurement Unit
SALD-2300
PC
750mm or more 650mm
The same samples must be measured by two instruments in order to
develop the parameter table for emulations.
SALD-DS5S
(Pressure regulator)
Dry Measurement System
SALD-DS5S
(SALD-2300 and SALD-DS5S) (Sampling unit and dispersion device)
1210mm or more
100mm 130mm
■ Mixture Data Simulation Function or more 820mm about 400mm
Allows simulating particle size distributions using any mixture ratio of multiple particle size distributions. This makes it possible to 100mm or more SALD-2300
determine the optimal mixture ratio for obtaining the desired particle size distribution, without repeatedly measuring the particle size Measurement Unit PC
distribution of sample mixtures.
750mm or more
■ Data Connecting Function 650mm
Allows combining the measurement results for two different measurement ranges at any particle size point to create a single particle size Wet/Dry Measurement Full System SALD-DS5S
distribution. For example, sieve data for particles above 2000 µm can be combined with SALD series data for particles below 2000 µm to (SALD-2300 and SALD-MS23 and SALD-DS5S) SALD-MS23 (Pressure regulator)
Sampler
SALD-DS5S
create a wide-ranging particle size distribution, which is required for civil engineering, disaster prevention, and environmental fields. (Sampling unit and dispersion device)
1450mm or more
SALD-2300
10 Laser Diffraction Particle Size Analyzer 11