Page 9 - Shimadzu Prominence
P. 9

LC-20AP
            Supporting Analytical and Preparative Scales
            The high solvent delivery performance of the LC-20AP permits an accurate and efficient environment for scaling up,
            in both the preparative and analytical flow rate ranges. The Prominence preparative system supports both analysis
            and fractionation (including gradient analysis and fractionation), which permits efficient scaling up with a single
            instrument and single operating environment. Combining the LC-20AP with a dedicated FCV-200AL low-pressure
            gradient unit allows gradient fractionation to be performed in a single unit, thereby saving equipment costs.

                Single System Supports Parameter Investigation and Scaling Up

                                                                                  mV
                                                                                               6
                                    Analytical injector                         800  A) Analytical  1  4  7  8
                                                                                700     2
                  Solvent delivery units  Analytical mixer  Analytical column            3  5
                                                                                600
                                                                                500
                                                   Column-switching valve       400
                                                                                300  B) Preparative
                                                          UV-VIS detector
                                                                                200
                                                                                100
                                                                                 0
                                                                                  0  2  4  6  8  10  12  14  min
                                                                                 1: Benzoic acid  5: Biphenyl  Column : A) 250 mmL. × 4.6 mmI.D.
                               Preparative mixer  Preparative column  Data   Fraction   2: 2-naphthol  6: Phenanthrene    B) 250 mmL. × 20 mmI.D.
                                                                                                   (5 μm, same packing material)
                                                                                 3: Benzene
                                                                                       7: Anthracene
                                    Preparative injector  processing collector   4: Naphthalene 8: Fluoranthene
                                                       unit
                                                                           Example of Scale-up with the Column of the Same Packing Material
                High-Precision Delivery Performance
                                                               mV
            A redesigned plunger actuation mechanism and                                        Samples
                                                                           1  2  3     4        (retention time at %RSD n = 6)
            improved pulse correction and check valves offers   1200                            1: Methylparaben
                                                            1000
            significantly improved flow rate accuracy and flow rate                             (0.015%RSD)
                                                             800
            precision. High retention time reproducibility for                                  2: Ethylparaben
                                                             600
                                                                                                (0.011%RSD)
            analytical flow rates improves reliability when scaling up   400                    3: Propylparaben
            and verifying purity.                            200                                (0.008%RSD)
                                                              0                                 4: Butylparaben
                                                                                                (0.010%RSD)
                                                                 1  2  3  4   5  6  7  8  9  10 min
                                                                                                Flow rate: 1.0 mL/min
                                                               Retention Time Reproducibility for Analytical Flow Rates
                LC-20AP Quaternary Enables Fractionation as a Low-Pressure Gradient System
            The LC-20AP Quaternary flow rate range is 1 to 50 mL/min and the instrument can handle up to four mobile phases simultaneously.
            It considerably reduces the effort required to investigate mobile phases during method development.nt.
                                                                                me
                                                                               p
              mAU
                                                                               , 15 μ
                                                                                   m
                                                                               .
                                               Column   Shim-pack PREP-ODS 250 mmL. × 20 mmI.D., 15 μm
                         Rosmarinic acid  Carnosol  Carnosic acid  Gradient program  B. Conc. 30 % (0 min) to 95 % (15 to 30 min) C. Conc. 5 %%
                                                                               acid solution
            1500                              Mobile phases  A: Water B: Methanol C: 2 % aqueous formic acid solution
                                                                               C
                                                                               . Conc. 5
            1000                            Column temperature  Room temperature
                                             Injection volume  200 μL
             500
                                               Flow rate  20.0 mL/min
              0                                Detection  UV 230 nm
                                                Sample  Rosemary extract
              0.0  5.0  10.0  15.0  20.0  25.0  min
            Degassing Units DGU-20A3R / 20A5R
            The DGU-20A3R/20A5R is an on-line degassing unit that uses fluoroethylene membrane. The internal
                                                                               nternal
            capacity is small at 0.4 mL, only 1/25th of that for existing Shimadzu models, and the waiting time at
            mobile-phase replacement or stabilization can be significantly reduced. The degassing efficiency has
            also been improved, ensuring thorough degassing even at high flow rates.
              Number of degassed solvents for DGU-20A3R : 3
              Number of degassed solvents for DGU-20A5R : 5
                                                                                                                     9
                                                                                             High Performance Liquid Chromatograph
   4   5   6   7   8   9   10   11   12   13   14