Page 4 - Shimadzu Prominence
P. 4

Superb Performance and Expandability







                Genuine High Throughput

            Reduced total analysis time
                                                           Start 0 m 00 s                          End 2 m 00 s
            The SIL-20A Series autosamplers achieve unparalleled
            speed, with a sample injection movement of just 10
                                                            inject  Analysis 1  inject  Analysis 2  inject  Analysis 3
            seconds. Prominence reduces the total analysis cycle
            time, not simply the time for the HPLC analysis itself.
            The optional rack changer permits the serial analysis of
            up to 4,068 samples.
            Prominence is an HPLC system that offers genuine high
            throughput.




                                                                Ultra-fast analysis of 7 components in 30-second cycles

                                                           Start 0 m 00 s                          End 3 m 00 s

                                                Other HPLC
                                             (injection time: 30 s)  Inject  Analysis 1  Analysis 2  Analysis 3



                                              Prominence UFLC
                                             (injection time: 10 s)  Analysis 1  Analysis 2  Analysis 3  33% faster!
                                                                                    End 2 m 00 s
                                                              Inject
                                                                  Comparison of total analysis times for 3 analyses by UFLC.
                                                                            * Example using 30 sec analysis time for each analysis




                                                                                                                                                                               CLASS-Agent
               Extremely Low Sample Carryover                                                                                                                     PACsolution
                                                                                                                                                  Multivendor compatibility               Web control
            Resolves a major problem with high-sensitivity analyses                                                                    Genzo Record
                                                                                                                                     Management System
            Basic compounds and hydrophobic compounds readily adsorb to the sample          Special needle coating
            path. Prominence restricts sample carryover to extremely low limits to avoid a                                                                                        LIMSsolution
            variety of problems that such compounds can cause. In addition, the
            multi-rinse mode achieves optimal rinsing for proteins and other sample
            components that are difficult to wash away.                                                                                                             LCMSsolution
            Prominence offers the optimal system for analyses demanding high
            sensitivity, such as impurity analysis and LC/MS.
                                                                                                                                                  LabSolutions



                                                      Minimized dead volume
                                                      at needle contact position








      4