Page 7 - Shimadzu PDA-8000
P. 7

Constant Monitoring of the Discharge Status
            Constant Monitoring of the Discharge Status
            A Realtime Energy Monitoring* function is provided to monitor the   Discharge defect
            discharge energy consumed between the counter electrode and the
            sample. The discharge energy is accurately set and controlled, and
            discharge defects due to the surface condition of the sample can be
            instantly detected from the discharge energy. The accuracy is improved
            by eliminating samples with defects from the measurement.
            *Patent pending











                                                                                          Real-time
                                                                                           energy
                                                                                          monitoring
            Supporting Diverse Metal Materials
            Supporting Diverse Metal Materials
            Many metal materials can be analyzed over a wide range of optimal discharge conditions, such as high-energy discharge for
            metals like steel with a high melting point, or low-energy discharge for metals like lead and zinc alloys with a low melting
            point, through the use of a newly-developed discharge energy stabilizing excitation unit.


            Ultra-Trace Analysis of High-Purity Materials
            Ultra-Trace Analysis of High-Purity Materials
            Current Regulative Spark* (CRS) which is capable of stabilizing the current for every pulse, improving sensitivity for trace
            amounts.
            *Patent pending





                                  Current

                                                                                       Current regulative spark (CRS)

                                                                                      Conventional arc-like discharge

                                                          Time

            Energy Ef
            Energy Efficient Design
                        ficient Design
            The power consumption is reduced to 510W (43 % reduction
            from our previous Optical Emission Spectrometer) * 1
            *1 For analyzing 15 samples/hour

            The argon gas consumption is also reduced by about 45 % from our previous Optical
            Emission Spectrometer. * 2
            *2 The consumption for analyzing 150 samples/8 hours in 1 day
                                                                                         *Discharge spot








                                                                                                                     7
   2   3   4   5   6   7   8   9   10   11   12