Page 7 - Shimadzu Nexera Mikros
P. 7

E a s y ,  F a m i l i a r  O p e r a t i o n



 Robust and Easy-to-Use Microflow ESI Source




                        ™
 Micro-ESI  Sources  LC-Mikros : Innovative Microflow Pump Design
 ™

 Shimadzu’s Micro-ESI LCMS source has been designed for optimal sensitivity and ease of use. An X–Y adjustable stage and viewing camera allow for easy ESI   Shimadzu LC pumps are the industry standard for long life and high performance. The LC-Mikros solvent delivery
 spray needle adjustment. The column oven is mounted on the LCMS to minimize the volume between the exit of the column and the ESI needle.  pump has completely new direct-drive engineering to deliver micro to semi-micro flow rates ranging from 1 to 500
 The Micro-ESI probe also features an ESI spray angle optimized for microflow rates, and is available for triple quadrupole mass detection mass spectrometry   µL/min. UHPLC system pressure tolerance of 80 MPa (11,600 psi) allows the use of every column type.
 and quadrupole time-of-flight mass spectrometry, respectively.  The LC-Mikros pump is designed for microflow gradient elution, even at low percentages. In the example below,
                                      excellent gradient stability is shown using mobile phase compositions ranging from 1% to 90%. The LC-Mikros
                                      delivers stable retention times essential to the chromatographer.






                            Average     Standard
                          Retention Time  Deviation  RSD       Flowrate: 5 µL/min
              Gly-Tyr        5.31        0.009       0.16%     Column:  Shim-pack MC C18 (0.3 mm I.D. × 150 mm)
              Val-Tyr-Val    7.97        0.006       0.07%
 Micro-ESI 8060  Micro-ESI 9030  Angiotensin II  9.32  0.015  0.16%  * Obtained under our specified conditions.
 (compatible with LCMS-8045/8050/8060(NX) systems)  Leu enkephalin  9.71  0.011  0.11%
              Met enkephalin  10.5       0.012       0.11%
               Time (min)  1     11   11.1   13   13.1   25
              Concentration B  1%  40%  90%  90%   1%   1%
 CTO-Mikros  + UF-Link : Easy, Dependable Column Installation
 ™
 ™
 Mounted to the Micro-ESI source is the CTO-Mikros column oven. Stable column temperature, essential to retention time reproducibility, is ensured and
 columns up to 150 mm in length can be accommodated. To preserve the optimal source adjustment, the CTO-Mikros features an innovative snap-in column
 locking system, the UF-Link.  SIL-40C XR: Low-Volume Direct Injection Autosampler
 When using microflow rates, even the smallest of dead volumes can cause significant diffusion and lead to loss of peak shape and sensitivity. Shimadzu’s
 UF-Link allows any user to correctly install a microflow column without disrupting the ESI spray needle position. A sure-sealing adapter allows the column to lock
 into the oven and make a zero-dead volume connection with the ESI needle. Any column up to 150 mm in length with standard fittings can be accommodated.  The SIL-40C XR autosampler delivers you excellent accuracy and reproducibility as well as extremely low carry-over. Its
                                      injection volume ranges from 0.1 to 50  L and your precious sample has never wasted due to the total injection
                                      method SIL-40C XR adapted.
 Existing Ferrule Seal Method  Zero Dead Volume Seal  It contributes to produce highly accurate results even if you had to use low injection volume (less than 1  L). In case
                                      of micro flow rate with narrow column, optimum injection volume also gets lowered. It is also difficult to increase the
 Male nut  Adapter
 Ferrule                              injection volume, especially, if you would use a sample solvent with high elution power. In this case, sample must be
                                      diluted to weaken the sample solvents. Highly accurate micro volume injection capability of SIL-40C XR allows you to
                                      use samples with high organic solvent contents without dilution.
                                       System volume and gradient delay are minimized with the newly developed “programmable loop cut-off
                                      mechanism,” which automatically diverts the sample loop from the flow line using a high-pressure valve as soon as
                                      the sample in needle is drained. This is extremely important in minimizing microflow analysis run times.

 Dead volume  Sealing part  Sealing part
                                                                                           Injection
                                                                 Injection
 Connection Procedure  8,000,000           R  = 0.9999          Volume (µL)  Repeatability (n = 6)  Volume (µL)  Repeatability (n = 6)
                                            2
             Area value  6,000,000                                 0.1       0.80%           2 5       0.08%
                                                                                                       0.06%
                                                                   0.2
                                                                             0.46%
               4,000,000
               2,000,000                                           0.5       0.32%           10        0.04%
                                                                   0.7       0.21%           20        0.04%
                   0                                                1        0.06%           50        0.03%
                    0      10      20     30      40     50
                                Injection volume (µL)                      Injection Repeatability (Actual Values)
 (1) Attach the adapter to the column. Standard   (2) Place the column in the UF-Link mechanism   (3) Complete the connection by swinging over
 threads on the adapter make it compatible   inside the oven.  the lever.
 with a wide variety of columns.
                                                                                            Nexera Mikros
 6                                                                                   Microflow Liquid Chromatography Mass Spectrometry System  7
   2   3   4   5   6   7   8   9   10   11   12