Page 11 - Shimadzu Nexera Mikros
P. 11

Shim-pack MC PLONAS Series  Shim-pack Trap Columns




 Various molecules give an increase in the peak intensity on Nexera Mikros LC-MS/MS platform with an MC PLONAS column.
              Trap Columns Wide Portfolio

 Shim-pack MC PLONAS C18
              Shim-pack MCT C18/C8
              70 MPa pressure limitation and a unique modification on the column inner surface protects
 3000  6.0e2  against absorption of the molecule.
 Aldosterone  359.2 > 189.3 (−)
              Shim-pack MCT LC18/LC8
 2500  5.0e2
 Micro        A small-volume cartridge column with 40 MPa pressure limit. Useful in reducing the gradient
 Semi-micro   delay for a low flow rate.
 2000  4.0e2

 1500  3.0e2
 Aldosterone 1 pg/mL
            Shim-pack MCT series                               Shim-pack MCT L series (particle size 5  m)
 1000
 2.0e2
               Part Number  Bonded Phase  Diameter (mm)  Length (mm)  Part Number  Bonded Phase  Diameter (mm)  Length (mm)
               228-59938-91               0.3                     227-32702-01   Trap column holder for Shim-pack MCT L
 500                           C18                    35
 1.0e2         228-59938-92               0.5                     227-32702-02    C18        0.3
                                                                                                         5
               228-59939-91               0.3                     227-32702-03    C8         0.5
                               C8                     35
 0             228-59939-92               0.5
 0.0e0
 1.0  2.0  3.0  4.0  5.0  1  2  3  4  5  (min)
 Column  : Shim-pack MC PLONAS C18 (0.2 mm I.D. × 100 mm L., 2.7  m)
 * Semi-micro data acquired with the 2.1 mm I.D. column which has the same chemical profile as an MC PLONAS column.
 Mobile phase  : A: Water, B: Methanol, gradient elution
 Flow rate  : 4  L/min  Nexera Mikros: Trap and Elute Configuration
 Temperature  : 50 ºC
 Injection volume : 1  L
 MS detection  : LCMS-8060, with Micro-ESI source, ESI (–)  The trap and elute system can be constructed by using a dedicated piping kit (228-71751-42).


                                              15  L Sample Loop                Nexlock ™  ID 0.05 mm × 100 mm
 Shim-pack MC PLONAS C8


 1. All-trans Retinol (A)  6                    SIL-40C XR        Trap column
 2. Epoxy-Menaquinone-4 (epoxy-MK-4)  5  A pump
 3. Menaquinone-4 (MK-4)  1                                                             Waste
 4. α-Tocopherol (E)  4
 5. Epoxy-Phylloquinone (epoxy-K1)  7     Mixer
 6. Phylloquinone (K1)                                              2  1
 7. Menaquinone-7 (MK-7)
                                                                  3      6
 3
 2                                                                  4  5
                            B pump                                        FCV-0206H
                           LC-40B X3
                                                                                              MS
 Column  : Shim-pack MC PLONAS C8 (0.2 mm I.D. × 100 mm L., 2.7  m)            Analysis column
 Mobile phase  : A: Ammonium acetate aq.         A pump
 B: Ammonium acetate in methanol, gradient elution
 Flow rate  : 4  L/min                                                    Nexlock ID 0.05 mm × 600 mm
 Temperature  : 50 ºC
 Injection volume: 0.2  L
 0.0  1.0  2.0  3.0  4.0  5.0  6.0  7.0  8.0  9.0  10.0 11.0 12.0 13.0 min  MS detection  : LCMS-8060, with Micro-ESI source, ESI (−)  Nexlock ID 0.05 mm × 100 mm
 20 pg on column                                 B pump
 * each peak is in full scale intensity
                                                   LC-Mikros

                                                                                            Nexera Mikros
 10                                                                                  Microflow Liquid Chromatography Mass Spectrometry System  11
   6   7   8   9   10   11   12