Page 10 - Shimadzu Nexera Mikros
P. 10

Shim-pack MC PLONAS Series                                                                                                Shim-pack Trap Columns




            Various molecules give an increase in the peak intensity on Nexera Mikros LC-MS/MS platform with an MC PLONAS column.
                                                                                                                                        Trap Columns Wide Portfolio

              Shim-pack MC PLONAS C18
                                                                                                                                        Shim-pack MCT C18/C8
                                                                                                                                        70 MPa pressure limitation and a unique modification on the column inner surface protects
            3000                                               6.0e2                                                                    against absorption of the molecule.
                                       Aldosterone  359.2 > 189.3 (−)
                                                                                                                                        Shim-pack MCT LC18/LC8
            2500                                               5.0e2
                                           Micro                                                                                        A small-volume cartridge column with 40 MPa pressure limit. Useful in reducing the gradient
                                           Semi-micro                                                                                   delay for a low flow rate.
            2000                                               4.0e2

            1500                                               3.0e2
                                                                                   Aldosterone 1 pg/mL
                                                                                                                                      Shim-pack MCT series                               Shim-pack MCT L series (particle size 5  m)
            1000
                                                               2.0e2
                                                                                                                                         Part Number  Bonded Phase  Diameter (mm)  Length (mm)  Part Number  Bonded Phase  Diameter (mm)  Length (mm)
                                                                                                                                         228-59938-91               0.3                     227-32702-01   Trap column holder for Shim-pack MCT L
             500                                                                                                                                         C18                    35
                                                               1.0e2                                                                     228-59938-92               0.5                     227-32702-02    C18        0.3
                                                                                                                                                                                                                                   5
                                                                                                                                         228-59939-91               0.3                     227-32702-03    C8         0.5
                                                                                                                                                         C8                     35
              0                                                                                                                          228-59939-92               0.5
                                                               0.0e0
                       1.0    2.0    3.0     4.0    5.0                   1       2      3       4      5    (min)
            Column       : Shim-pack MC PLONAS C18 (0.2 mm I.D. × 100 mm L., 2.7  m)
                         * Semi-micro data acquired with the 2.1 mm I.D. column which has the same chemical profile as an MC PLONAS column.
            Mobile phase  : A: Water, B: Methanol, gradient elution
            Flow rate    : 4  L/min                                                                                                     Nexera Mikros: Trap and Elute Configuration
            Temperature  : 50 ºC
            Injection volume : 1  L
            MS detection  : LCMS-8060, with Micro-ESI source, ESI (–)                                                                 The trap and elute system can be constructed by using a dedicated piping kit (228-71751-42).


                                                                                                                                                                        15  L Sample Loop                Nexlock ™  ID 0.05 mm × 100 mm
              Shim-pack MC PLONAS C8


            1. All-trans Retinol (A)              6                                                                                                                       SIL-40C XR        Trap column
            2. Epoxy-Menaquinone-4 (epoxy-MK-4)  5                                                                                                    A pump
            3. Menaquinone-4 (MK-4)  1                                                                                                                                                                            Waste
            4. α-Tocopherol (E)                 4
            5. Epoxy-Phylloquinone (epoxy-K1)           7                                                                                                           Mixer
            6. Phylloquinone (K1)                                                                                                                                                             2  1
            7. Menaquinone-7 (MK-7)
                                                                                                                                                                                            3      6
                                               3
                                             2                                                                                                                                                4  5
                                                                                                                                                      B pump                                        FCV-0206H
                                                                                                                                                     LC-40B X3
                                                                                                                                                                                                                        MS
                                                               Column     : Shim-pack MC PLONAS C8 (0.2 mm I.D. × 100 mm L., 2.7  m)                                                                    Analysis column
                                                               Mobile phase  : A: Ammonium acetate aq.                                                                     A pump
                                                                           B: Ammonium acetate in methanol, gradient elution
                                                               Flow rate  : 4  L/min                                                                                                                Nexlock ID 0.05 mm × 600 mm
                                                               Temperature  : 50 ºC
                                                               Injection volume: 0.2  L
            0.0  1.0  2.0  3.0  4.0  5.0  6.0  7.0  8.0  9.0  10.0 11.0 12.0 13.0 min  MS detection  : LCMS-8060, with Micro-ESI source, ESI (−)                                          Nexlock ID 0.05 mm × 100 mm
            20 pg on column                                                                                                                                                B pump
            * each peak is in full scale intensity
                                                                                                                                                                            LC-Mikros

                                                                                                                                                                                                                      Nexera Mikros
      10                                                                                                                                                                                                       Microflow Liquid Chromatography Mass Spectrometry System  11
   5   6   7   8   9   10   11   12