Page 9 - Shimadzu LCMS-9050
P. 9

iMScope    ™                                    CLAM    ™

               Imaging Mass Microscope                         Fully Automated Sample Preparation Module for LCMS


               This unit is equipped with the laser ionization   Simply set up the blood collection tube, and
               source and optical microscopy to allow direct   fully automated analysis of blood and urine
               comparison of molecular distribution and        samples, from pretreatment to LC/MS/MS

               histological features. In combination with a Q-TOF   analysis, is realized, improving workflow

               spectrometer, it enables accurate and fast      efficiency. In order to obtain a full scan of a

               high-resolution MS image acquisition and analysis.  valuable sample and to collect exhaustive data,
                                                               Q-TOF is the best combination for this purpose.




                        ™
               Nexera  UC
               Supercritical Fluid Extraction / Chromatograph System


               This system uses a supercritical fluid to automatically

               extract and separate target components. SFC can

               separate and analyze compounds in a wide range of

               chemical space, from low to high polarity. Combined

               with the LCMS-9050's positive-negative switching

               mode, compounds with a wide range of

               physico-chemical properties can be analyzed at once,

               increasing the comprehensiveness of a single analysis.

               Using the SFC+LCMS-9050 system, 80 pesticide        (x100,000)
                                                                1 75
               compounds were simultaneously analyzed using the   1 50
               positive-negative switching mode. The use of     1 25
                                                                1 00
               supercritical fluid as the mobile phase enables   0 75
               analysis with higher speed, separation, and sensitivity   0 50
               than HPLC. By combining the supercritical fluid   0 25
                                                                0 00
               system with the high-resolution Q-TOF, the system is   0 0  2 5  5 0  7 5  10 0  12 5  15 0  min
               powerful for full screening of multiple components.
                                                                 80 components of pesticides Mass Chromatogram






               Nexera Mikros      ™

               Supporting Micro Flowrate Range Liquid Chromatography
               Mass Spectrometry System

               This LCMS system is optimized for low flowrates. Higher
               ionization efficiency and higher ion-uptake efficiency
               enable higher sensitivity. In combination with a Q-TOF
               system, it can be used for comprehensive analysis of trace
               components.






                                                                                                                   9