Page 8 - Shimadzu LCMS-9050
P. 8

Truly versatile with flexible extensions







                     A wide variety of analytical challenges can be further addressed by combining the Q-TOF capability

                     with optional ionization units or with unique front-end configurations. These flexible extensions

                     can be easily implemented and switched with little or no intervention of engineers.



                     DPiMS   ™

                     Direct Probe Ionization Mass Spectrometer


                     A small amount of sample is taken using a
                     probe and directly ionized to measure liquids

                     and solids as they are. There is no need to study

                     LC separation conditions or complicated sample

                     preprocessing. Data acquisition can be

                     completed within 1 minute even if both positive

                     and negative ions are detected. By combining

                     with Shimadzu's Q-TOF, it becomes possible to

                     quickly and easily identify the components in

                     the sample.


                     0.0 min                                0.3min  0.31min                              0.6min

                                      Negative Ion                                Positive Ion


                     TIC( )                                       TIC(+)

                     100 00                                      100 00
                       %                                           %


                      0 00                                        0 00
                        0 00  0 04  0 08  0 12  0 16  0 20  0 24  0 28  min  0 32  0 36  0 40  0 44  0 48  0 52  0 56  min
                                                       Total Ion Chromatograms

                                                                     (×100,000)
                        (×100,000)  253 8088                                     360 3224
                                                                                  376 2961
                      3 0                                          2 8
                                                                   2 4
                      2 5
                                                                   2 0
                      2 0  126 9045  299 8022                                                 697 6558
                                                                   1 6
                      1 5
                                                                   1 2             377 3000     698 6592

                      1 0
                         59 9846                                   8 0   266 1674  425 1352  695 6402
                            152 9076                                                             713 6304
                      5 0                  388 2982                          288 2891  426 1385          808 5790
                                    380 7135                       4 0  104 1068  358 3072  427 1355
                            198 9006  344 8486  448 9888                                         714 6338
                                                                                                 780 5486
                                                                        147 1127      527 1817  643 6091  927 7048
                      0 0                                           0 0
                         100  200  300  400  500  600  700  800  900  m/z  100  200  300  400  500  600  700  800  900  m/z
                                                           Mass Spectrum
        8
   3   4   5   6   7   8   9   10   11   12