Page 5 - Shimadzu LCMS-8060NX
P. 5

The Culmination of Shimadzu's Expertise in

 Triple Quadrupole Mass Spectrometry





 IonFocus  unit  NEW  UFsweeper™ Ⅲ collision cell                       Ultra-fast detector
 ™
 A newly-developed ESI probe with focus electrodes   UFsweeper is a unique Shimadzu technology which   A detector boasting ultra-fast response
 introduces ions into the mass spectrometer more   effectively sweeps ions from the collision cell without   enables sensitive and stable signal detection
 ef ciently, while expelling contaminants to reduce   deceleration. Crosstalk is virtually eliminated and   even with a short pause time, dwell time and
 noise and provide more stable data. In addition, an   high-sensitivity analysis is maintained, even at high   polarity switching time.
 improved heat-assist design promotes the ionization   acquisition speeds. The high-speed transport technology of
 of a wide range of compounds. (Patented technology.)  UFsweeper III minimizes ion loss even at the highest data
               acquisition rate of 0.8 msec. Increase laboratory throughput
               with an MRM speed of 555 channels per second.


 Simple design without
 cables or tubes. Remove
 Focus
 or replace easily with the  electrodes
 "one-touch" lever.



 Heating gas
 with improved   Ions are introduced
 heat transfer   more ef ciently
 ef ciency
 Contaminants



 Ultra-fast power supply

 The unique high-voltage power supply enables high-speed polarity switching in 5 ms for
 high-throughput simultaneous analysis of multiple analytes.




 Easy maintenance interface
 The LCMS-8060NX inherits all the ease-of-maintenance of its predecessors. Both the desolvation line (DL), which
 introduces the sample into the vacuum, and the ESI capillary can be replaced easily and in a short time. The DL
 can be replaced while maintaining the vacuum, minimizing downtime.

 • Steps to replace the DL
 2
 1

 3
 DL(Desolvation Line)
                              UF-Qarray Ⅱ, UF-Lens Ⅱ      NEW                        Quadrupole rods
                                        ™
                                                    ™
 • Steps to replace the ESI capilliary
                                         Re-engineered ion guide improves         A high-performance hyperbolic mass
                                         robustness without compromising on        lter with a proven track record
 3
 1                                       sensitivity. Maintenance of UF-Qarray II   maintains high ion transmittance
 2                                       and UF-Lens II can be performed easily   and high sensitivity, even at a
 ESI Capillary                           without tools.                           scanning rate of 30,000 u/s.
   1   2   3   4   5   6   7   8   9   10