Acquisition for All Wavelengths Allows You to Freely Add Elements and Wavelengths
Acquisition for All Wavelengths
Even after measurements are finished, the elements and wavelengths can be added, which allows you to confirm the
quantitative or qualitative data. Because data are acquired for all wavelengths, there is no need to reanalyze samples.
Adding Quantitative The quantitative values can be displayed by simply adding elements or wavelengths. This is especially helpful when you
Analysis forgot to specify an element to be measured or want to obtain data for other wavelengths.
Adding Qualitative The profiles and semi-quantitative values can be loaded and confirmed for all elements. This is useful for determining
Analysis the approximate concentrations of elements that were not quantitated, for example to confirm matrices.
Once data for all wavelengths have been saved, it can be loaded and reanalyzed at any time. This availability of data
Reanalyzing Data from provides peace of mind in case something unexpected happens with quality control or when analyzing samples that are
Previous Analyses
only available in small quantities.
Three Functions Make Method Optimization Easy
Automatic Wavelength Selection
This function automatically selects the
optimal wavelengths for the measurement
BEST
sample based on the SB ratio and whether
or not there is interference from the matrix.
BEST!
Diagnosis Assistant
This function automatically checks for any Data a a a Database
problems with the method and, if any are
Measurement Data Problems identified
discovered, it suggests the best way to Results
Multiple The function also suggests how to
resolve them. This allows anyone to quickly wavelengths resolve such problems.
Calibration
obtain accurate analytical values. curve samples Matrix 1. Addition of wavelengths
interference 2. Background correction
3. Interelement correction
4. Addition of calibration curve samples
5. Matrix matching etc.
Interelement Correction +α Also Smart At Creating Methods Before Analysis
B
C This function is useful if high-matrix samples
cannot be quantitated accurately due to Method Development Assistant
optical interference at all analytical This function uses the results of qualitative
wavelengths. ICPEsolution software allows analysis to automatically create a method
users to easily perform interelement (including wavelengths and calibration curve
correction by simply adding a calibration concentrations) depending on the concentra-
sample for the interfering element to the tions of the elements targeted for measurement
calibration curve sample. and the matrix in the sample. User method
development can be performed smoothly.