Page 12 - Shimadzu ICPE-9800 Series
P. 12

Acquisition for All Wavelengths and Assistant Functions Ensure a Smoother Analysis Process


            The ICPE-9800 series’ assistant functions, which combine extensive spectral data with a substantial database, enable easy optimization
            of methods and a simpler, more efficient analytical workflow.



                             Typical Systems                                   ICPE-9800 Series


                                                      Prepare sample.


                                                    Select elements and
                                                       wavelengths.                               Data

                                                                                               Data  Data
                                                          Prepare
                                                     calibration curve.                        Data  Database
                                                                                               Data
                                                                                                 Data
                                                         Measure.


                                                                                          Acquisition for
                                              Case                                        All Wavelengths
                                                                                          Additional data can be loaded
                                                                                          later, which eliminates the need
                                                                                          to analyze samples again.
                                         1. The user forgot to register elements
                                          and wavelengths. Selected
                                          wavelength resulted in an overflow.
                                                                                          Automatic
                                                                                          Wavelength Selection
                                         2. Multiple wavelengths were selected,           The software selects the
                                          but the optimal wavelength cannot         BEST  optimal wavelength.
                                          be determined.

                                         3. Measured values are not what were             Diagnosis Assistant
                                          expected. Why are they different from           The assistant feature
                                          reference values or estimated values?
                                                                                          automatically diagnoses
                                                                                          methods. Let the software
                                                                                          check for any interference.
                                         4. Matrix interference at all wavelengths
                                          prevents correct results from being
                                          obtained.
                                                                                          Interelement
                                                                                    B
                                                                                      C   Correction
                                                                                          Interelement correction is
                                                                                          easy, too!




                                                          Results





      12
   7   8   9   10   11   12   13   14   15   16   17