Page 4 - Shimadzu HMV-G Series
P. 4
Select the System to
Suit the Situation
HMV-G31-FA Series
High Ef ciency, Completely Automatic
Measurements Using the Electric XYZ Stage
and Special Software
Stage Viewer
Search the stage, and overlap the image data to create a total image.
HMV-G31 Series Also, the stage can be moved to the measurement position from the total
image obtained.
Automatic Sample Shape Recognition
Standardized automatic length The system recognizes the shape of the sample, and sets the test position
measurement function using a using this information.
digital camera built into a novel General Purpose Test Pattern Settings
G frame The coordinates of test positions are set using Excel data. As a result,
programs can be created on a PC without installing special software.
Angular adjustments to suit the sample orientation are made easily while
observing the actual sample.
G Frame G31 G30 FA Intelligent Software G31 FA
The Following Situations Are Envisioned:
The corner-less, elegant frame disperses The software automatically sets the optimal indentation test force from the
the load uniformly for stability, and anticipated hardness and anticipated indentation depth. Machine Industry Field
extends in the depth direction to Further, the software automatically sets the optimal lens magni cation from
expand the work space and improve the anticipated hardness. The goal is to evaluate the hardness distribution of parts with The goal is to measure the depth of hardening due to heat
operability. Additionally, because the complicated shapes such as gears used in automobiles, aircraft, treatment, but measurement point positioning and calculations
central part of the frame is open, long Automatic High Speed Readings G31 FA ˠ See page 6 and hydraulic equipment, but determining measurement are dif cult.
narrow samples can now be measured positions is dif cult.
as is. One sample can be read in 0.3 seconds. (for monochrome cameras only) There are many test points, and measurement is dif cult.
Compact Design with a Built-in Digital Camera G31 FA
Multi Turret (D Type) G31 G30 FA
The digital camera is built in, so the design is compact.
Two indenters and four lenses can be attached.
Automatic Lens Switching (T Type) G31 FA HMV-G30 Series
User-Designated Test Force Settings G31 G30 FA
After the automatic reading is taken, the lens is automatically switched to
Using electromagnetic control, tests can be performed with a user-designated suit the size of the indentation. Turn it ON and Start Measuring Immediately. Active in Educational Fields.
test force from 9.807 mN (HV0.001) to 19.61 N (HV2). (Minimum increment
of 9.807 mN) Reading of Scored Surfaces G31 FA
Test Conditions Assist Function G31 G30 FA The software can read not only samples with a mirror nish, but also Simple Test Mode
samples scored by etching.
This function can select the optimal lens from the anticipated hardness, or Simple test mode can be selected to start testing immediately just by
determine the optimal test force from the anticipated indentation depth and Routine Inspection Graphs G31 FA setting the test force and the retention time.
hardness.
The average hardness per lot is displayed in a graph, so the user can check LCD Data Graphs
Fracture Toughness Measurements G31 G30 FA changes in hardness. The data are displayed in graphs, and it is easy to re-select or re-measure data.
$PMPS $BNFSB .PEFM
$PMPS $BNFSB .PEFM
The system can measure the crack length when the indenter makes an G31 FA ˠ See page 7
indentation, so the fracture toughness of brittle materials can be measured. LCD Touch Panel ˠ See page 7
Models with color cameras are available.
Measurement Mode Settings G31 G30 FA 64# $PNNVOJDBUJPO XJUI B (FOFSBM 1VSQPTF 1$ The simple window con guration is easy to use. In addition to test condition
64# $PNNVOJDBUJPO XJUI B (FOFSBM 1VSQPTF 1$ G31
settings, statistical graphs are displayed to summarize the results.
The user can select standard testing, in which the indentation is read after
each test, or consecutive testing, in which the reading is taken after a number Connect to a PC with just two USB cables. (Excluding the models with an Direct USB Transfers
of test cycles. electric stage)
&MFDUSJD .JDSPNFUFS 0QUJPOBMMZ "WBJMBCMF G31 ˠ See page 9 Just connect a USB ash drive to the instrument to automatically save data
in CSV format.
After purchasing the HMV-G31/HMV-G21, if the electric micrometer option
is subsequently added, the simpli ed electric XY stage function can be used. Sleep Mode
Sleep mode starts up when the instrument is not in use, conserving power.
The Following Situations Are Envisioned:
Surface Processing and Etching Fields Solar Cell Field
There is a shortage of trained users, and the data varies signi - The goal is to evaluate the hardness of metal foils such as those
cantly depending on the analyst. used in solar cell wiring, but the foils cannot be measured because The Following Situations Are Envisioned:
There are scratches on the surfaces of lead frames and mechani- the test forces are too great.
cal parts, so measuring indentation lengths is dif cult. The goal is to evaluate not only Micro Vickers hardness, but also Knoop Transport Equipment Field
Statistical controls should be implemented to evaluate quality hardness and other hardness types, but switching indenters is dif cult. The goal is to measure the hardness of camshafts and other Users wish to avoid using PCs on-site.
stability, but there are not enough personnel. The goal is to evaluate a variety of materials ranging in quality from long samples, but the tests cannot be performed because the
The goal is to measure a range of samples, even those with hard to soft. However, this is dif cult because test forces are inap- instrument cannot accommodate the samples. Measuring samples for the rst time is problematic because
the degree of indentation force and magni cation for mea-
unknown hardness levels. propriate, and the lens magni cation may not suit the indentation. surement are unknown.
HMV-G
Micro Vickers Hardness Tester
4 5