Page 4 - Shimadzu HMV-G Series
P. 4

Select the System to

                  Suit the Situation

                                                                                                                                           HMV-G31-FA Series

                                                                                                                                           High Ef ciency, Completely Automatic
                                                                                                                                           Measurements Using the Electric XYZ Stage
                                                                                                                                           and Special Software
                                                                                                                                           Stage Viewer
                                                                                                                                           Search the stage, and overlap the image data to create a total image.
                  HMV-G31 Series                                                                                                           Also, the stage can be moved to the measurement position from the total
                                                                                                                                           image obtained.
                                                                                                                                           Automatic Sample Shape Recognition
                  Standardized automatic length                                                                                            The system recognizes the shape of the sample, and sets the test position
                  measurement function using a                                                                                             using this information.
                  digital camera built into a novel                                                                                        General Purpose Test Pattern Settings
                  G frame                                                                                                                  The coordinates of test positions are set using Excel data. As a result,
                                                                                                                                           programs can be created on a PC without installing special software.
                                                                                                                                           Angular adjustments to suit the sample orientation are made easily while
                                                                                                                                           observing the actual sample.
                  G Frame G31 G30  FA                           Intelligent Software G31 FA
                                                                                                                                             The Following Situations Are Envisioned:
                  The corner-less, elegant frame disperses      The software automatically sets the optimal indentation test force from the
                  the load uniformly for stability, and         anticipated hardness and anticipated indentation depth.                      Machine Industry Field
                  extends in the depth direction to             Further, the software automatically sets the optimal lens magni cation from
                  expand the work space and improve             the anticipated hardness.                                                     The goal is to evaluate the hardness distribution of parts with   The goal is to measure the depth of hardening due to heat
                  operability. Additionally, because the                                                                                      complicated shapes such as gears used in automobiles, aircraft,   treatment, but measurement point positioning and calculations
                  central part of the frame is open, long       Automatic High Speed Readings G31 FA  ˠ See page 6                            and hydraulic equipment, but determining measurement   are dif cult.
                  narrow samples can now be measured                                                                                          positions is dif cult.
                  as is.                                        One sample can be read in 0.3 seconds. (for monochrome cameras only)                                                      There are many test points, and measurement is dif cult.
                                                                Compact Design with a Built-in Digital Camera G31 FA
                  Multi Turret (D Type) G31 G30 FA
                                                                The digital camera is built in, so the design is compact.
                  Two indenters and four lenses can be attached.
                                                                Automatic Lens Switching (T Type) G31 FA                                   HMV-G30 Series
                  User-Designated Test Force Settings G31 G30  FA
                                                                After the automatic reading is taken, the lens is automatically switched to
                  Using electromagnetic control, tests can be performed with a user-designated   suit the size of the indentation.         Turn it ON and Start Measuring Immediately. Active in Educational Fields.
                  test force from 9.807 mN (HV0.001) to 19.61 N (HV2). (Minimum increment
                  of 9.807 mN)                                  Reading of Scored Surfaces G31 FA
                  Test Conditions Assist Function G31 G30 FA    The software can read not only samples with a mirror  nish, but also       Simple Test Mode
                                                                samples scored by etching.
                  This function can select the optimal lens from the anticipated hardness, or                                              Simple test mode can be selected to start testing immediately just by
                  determine the optimal test force from the anticipated indentation depth and   Routine Inspection Graphs G31 FA           setting the test force and the retention time.
                  hardness.
                                                                The average hardness per lot is displayed in a graph, so the user can check   LCD Data Graphs
                  Fracture Toughness Measurements G31 G30 FA    changes in hardness.                                                       The data are displayed in graphs, and it is easy to re-select or re-measure data.
                                                                $PMPS $BNFSB .PEFM
                                                                $PMPS $BNFSB .PEFM
                  The system can measure the crack length when the indenter makes an   G31 FA  ˠ See page 7
                  indentation, so the fracture toughness of brittle materials can be measured.                                             LCD Touch Panel ˠ See page 7
                                                                Models with color cameras are available.
                  Measurement Mode Settings  G31 G30 FA         64# $PNNVOJDBUJPO XJUI B (FOFSBM 1VSQPTF 1$                                The simple window con guration is easy to use. In addition to test condition
                                                                64# $PNNVOJDBUJPO XJUI B (FOFSBM 1VSQPTF 1$ G31
                                                                                                                                           settings, statistical graphs are displayed to summarize the results.
                  The user can select standard testing, in which the indentation is read after
                  each test, or consecutive testing, in which the reading is taken after a number   Connect to a PC with just two USB cables. (Excluding the models with an   Direct USB Transfers
                  of test cycles.                               electric stage)
                                                                &MFDUSJD .JDSPNFUFS  0QUJPOBMMZ "WBJMBCMF   G31 ˠ See page 9               Just connect a USB  ash drive to the instrument to automatically save data
                                                                                                                                           in CSV format.
                                                                After purchasing the HMV-G31/HMV-G21, if the electric micrometer option
                                                                is subsequently added, the simpli ed electric XY stage function can be used.  Sleep Mode
                                                                                                                                           Sleep mode starts up when the instrument is not in use, conserving power.
                    The Following Situations Are Envisioned:
                    Surface Processing and Etching Fields       Solar Cell Field
                     There is a shortage of trained users, and the data varies signi -  The goal is to evaluate the hardness of metal foils such as those
                     cantly depending on the analyst.            used in solar cell wiring, but the foils cannot be measured because         The Following Situations Are Envisioned:
                     There are scratches on the surfaces of lead frames and mechani-  the test forces are too great.
                     cal parts, so measuring indentation lengths is dif cult.  The goal is to evaluate not only Micro Vickers hardness, but also Knoop   Transport Equipment Field
                     Statistical controls should be implemented to evaluate quality   hardness and other hardness types, but switching indenters is dif cult.  The goal is to measure the hardness of camshafts and other   Users wish to avoid using PCs on-site.
                     stability, but there are not enough personnel.  The goal is to evaluate a variety of materials ranging in quality from   long samples, but the tests cannot be performed because the
                     The goal is to measure a range of samples, even those with   hard to soft. However, this is dif cult because test forces are inap-  instrument cannot accommodate the samples.  Measuring samples for the  rst time is problematic because
                                                                                                                                                                                          the degree of indentation force and magni cation for mea-
                     unknown hardness levels.                    propriate, and the lens magni cation may not suit the indentation.                                                       surement are unknown.
                                                                                                                                                                                                                                HMV-G
                                                                                                                                                                                                                             Micro Vickers Hardness Tester
      4                                                                                                                                                                                                                                        5
   1   2   3   4   5   6   7   8   9