Inert Flow Path Achieves High-Sensitivity
Smart Database Series Supporting Accurate Quantitative Determinations GC/MS Flow Path
in MRM Analysis
The series contains optimized analysis conditions, so users can start an analysis immediately without investigating the conditions. Minimizing adsorption and other losses in the flow path from sample injection to the detector is important for stable, high-sensitivity
This database is for accurate quantitative determinations using standard samples. measurements using GC/MS. The flow lines in the GCMS-QP series and the TQ series consist of high-quality, highly reliable
consumable parts, so even trace concentrations of components can be detected with high sensitivity and favorable repeatability.
Smart Pesticides Database Smart Metabolites Database
It covers the pesticides (530 compounds) The database contains 525 compounds Glass liner Micro-syringe
subject to GC-MS analysis and used inside including metabolites contained in blood,
and outside Japan. The database also urine, cells and other biological samples. It The Restek glass liner recommended for Autosampler syringes feature
improved durability, clarity, and
GCMS analysis uses a proprietary
contains information on compounds that also contains information on the stable inactivation technology to dramatically accuracy, achieving reliable injection
can be used as internal standards. isotopes of 22 major metabolites, which suppress active sites. After packing into accuracy.
Therefore, it also supports analysis with the can be used as internal standards. the insert, the wool is subjected to a
internal standard method. complete inactivation treatment. This
product is controlled throughout from
production to final inspection to provide GC septum
100 % satisfaction. Our lineup now includes low bleed
Smart Environmental Database Smart Forensic Database septa, which maintain optimal seal
TIC performance even when the
The database contains information on 527 The database is registered with 486 Resolution (%) Endrin p,p'-DDT injection cycles are increased, and
compounds including polychlorinated forensic toxicological substances often Endrin: 1.34 can be used even at high
biphenyl, brominated flame retardants, involved in poisonings, such as drugs of DDT: 1.44 temperatures. This reduces
dioxins, polycyclic aromatic hydrocarbons, abuse, psychotropic drugs, sensitivity variations due to leaks.
and organochlorine pesticides, as well as pharmaceuticals, and pesticides. Endrin aldehyde Endrin ketone
their stable isotope labeled compounds. p,p'-DDE p,p'-DDD Ferrules and gold gasket
The high-quality Vespel ferrule is
easily attached and designed to
In particular, the "Smart Environmental Database" is extremely useful for analysis of environmental pollutants, which require trace resist leaking. The gold gasket is
analysis. inactive, and adsorption does not
Not only are MRM information and stable isotope labeled compounds (IS) for target analysis components registered in the Smart occur.
Environmental Database, but also the optimal columns for separating each compound are set, so trace analysis can be smoothly
performed without having to set the conditions for each compound.
(×10,000)
6.0
5.0
#81
4.0 #77
#118 #167 #156
3.0 #123 #114 #105 #126 #157 #169
#189
2.0
1.0
39.0 40.0 41.0 42.0 43.0 44.0 45.0 46.0 47.0 48.0 49.0 50.0 51.0 52.0 53.0 54.0 55.0
Dioxin-Like PCBs (50 fg/µL concentration)
271.8>236.9 194.9>160.0
273.8>238.9 338.9>160.0
Ion source Capillary columns
Designed with a shield that blocks radiant heat For the SH-Rxi series, a high-quality fused silica like
12.5 13.0 14.5 15.0 generated by the filament, and an ion source no other is used as the raw material. Our proprietary
treated with an oxide coating, active spots inside surface inactivation technology and optimal process
Heptachlor (50 fg/µL concentration) alpha-Endosulfan (50 fg/µL concentration) the ion source are not prone to occur, which to mask silanol groups result in a low-bleed column
enables high-sensitivity analysis with long-term with very impressive inactivation performance, even
stability. with respect to polar compounds comparable to
acidic and basic substances.