Page 6 - Shimadzu GCMS-TQ8050 NX
P. 6

Active-Time Management That Accurately Determines Downtime



             Instrument Startup/Shutdown Time Management                                                                              Time Management for Continuous Analysis

            The mass spectrometer has to be operated in a vacuum condition, so the downtime for starting up and stopping the instrument is very long.   By displaying the time required for continuous analysis in real time, the time when the current continuous analysis will finish can be accurately
            Since the amount of time that the system takes when starting up or stopping is displayed in real time, it is easy to accurately determine when   confirmed. It can increase the instrument operating time (active time) by reducing the instrument downtime required during continuous
            maintenance of ion source or analysis is possible. Moreover, tasks that until now needed to be performed by the user, such as leak checks   analysis or while switching between different users. In addition, because this function makes it easier to schedule the timing for analysis
            upon system startup and auto tuning, are now performed automatically.                                                     preparations, such as sample preparation and pretreatment, based on the finish time of the previous analysis, it enables analytical processes
                                                                                                                                      to be performed more efficiently, which can help improve work-life balance.















                               Auto Startup and Shutdown






                                                                            Auto Tuning Check Result                                     Simple Column Replacement Using the Twin Line MS System

                                                                                                                                      By connecting the outlet ends of two different columns to the MS unit at the same,   289.9>219.9
             Time Management during Sample Injection Port Maintenance                                                                 different application data can be acquired without shutting OFF the MS vacuum.  291.9>221.9
                                                                                                                                      Since no flow restrictors are used, there are no losses from adsorption or other
            The Easy sTop function, used to safely maintain the sample injection port without releasing the vacuum, displays the remaining time   factors, and methods and retention times used for analysis with one column can
            (cooling-down time) when the septum or the insert can be replaced in real time. Downtime caused by maintenance can be minimized by   continue to be used unchanged. The new large-capacity differential vacuum system
            understanding the accurate remaining time.                                                                                ensures sensitivity does not decrease even when two columns are connected.
            Furthermore, by using a ClickTek nut on the sample injection port, the port can be opened or closed without tools, by simply using fingers to   Due to the separation from impurities and separation between isomers, the system
            twist a lever. That enables faster and easier insert replacement than ever before.                                        can switch between different types of columns for measurements without actually
                                                                                                                                      replacing columns.
                                                                                                                                                                                                               24.0         24.5
                                                                                                                                                                 Twin Line MS System
                                                                                                                                                                                                        Example of PCB Analysis in River Water
                                                                                                                                                                                                       Column: Rtx-PCB (60 m, 0.25 mm, and 0.25 mm)
                                                                                                                                                                                                2,2', 5,5'-Tetrachlorobiphenyl (#52) (0.080 ng/L concentration in water)
                                                                                                                                                                                                          643.6>483.7
                                                                                                                                                                                                          643.6>485.7










                                                                          ClickTek Nut                                                                                                                          22.0        23.0
                                                                                                                                                                                                        Example of PBDE Analysis in Sediment
                                                                                                                                                                                                       Column: Rtx-1614 (30 m, 0.25 mm, and 0.1 mm)
                                                                                                                                                                                                       2,2', 4,4', 5,6'-Hexabromodiphenyl ether (#154)
                               Easy sTop Function                                                                                                                                                         (0.436 ng/g concentration in sediment)



      10                                                                                                                                                                                                                Gas Chromatograph Mass Spectrometer  11
   1   2   3   4   5   6   7   8   9   10