RoHS Compliance Screening Analysis Instruments


                    Energy Dispersive X-ray Fluorescence Spectrometer                                                                        Screening System for Phthalate Esters
                    EDX-7000/8000/8100                                                                                                       Py-Screener

                    • High Sensitivity, High Speed, and High Resolution                                                                       Making the Difficult Simple
                                      , and high r
                     High speed, high sensitivity, and high resolution SDD detector and optimized hardware achieve the highest                The Py-Screener system is designed to screen for phthalate esters in polymers.
                     High speed, high sensitivity
                                             esolution SDD detector and optimized har
                                                                      dwar
                                                                         e achieve the highest
                     level of analysis performance in its series.                                                                             The use of phthalate esters in toys and food packaging is currently restricted.
                    • Accommodates Various Types and Sizes of Samples                                                                         Moving forward, they are expected to be regulated as restricted substances under
                     EDX-7000/8000/8100:                                                                                                      the RoHS (II) Directive.
                      The combination of Small Spot Analysis Kit and EDXIR-Analysis Software facilitate the contaminant analysis.             The Py-Screener system consists of special software, special standard samples, and
                      The combination of Small Spot Analysis Kit and EDXIR-Analysis Software facilitate the contaminant analysis.
                      Turret for 12 samples permits continuous measurement.                                                                   a sampling toolkit, which supports the entire process from sample preparation to
                     EDX-7000/8100:                                                                                                           data acquisition, data analysis, and maintenance. It provides an environment in
                      Vacuum Measurement Unit (also accommodates EDX-8000) and Helium Purge Unit enable the analysis of
                      Vacuum Measurement Unit (also accommodates EDX-8000) and Helium Purge Unit enable the analysis of                       which operations are simple, even for novices.
                      liquid, powder and solid samples.
                     EDX-8000/8100:
                      The wide-range detector permits the range of detected elements from C to U.
                    • Easy Operation
                                                            estricted material analysis and r
                                                       ective r
                                                                               eport
                     PCEDX-Navi software allows easy operation for RoHS directive restricted material analysis and report
                                 e allows easy operation for RoHS dir
                     PCEDX-Navi softwar
                     creation even for beginners.
                                                                                                                                              Feature
                    High Sensitivity − Lower Limit of Detection Improved 1.5 to 5 Times!  −                                                   Organics Solvents Are Not Required for Sample Preparation
                    The high-performance SDD detector and combination of optimized optics and primary filters achieve previously unheard-of high   Analytical standards and test samples can be prepared without using organic solvents. To prepare a sample, just use the cutter to
                    levels of sensitivity. The sensitivity is higher than the previous Si (Li) semiconductor detector across the entire range from light to   remove a portion from the test material, place it in the sample cup, and weigh it. Sample preparation videos provide support so that
                    heavy elements.                                                                                                           even novices can easily prepare samples.
                   Lower limit of detection [ppm]
                                                    EDX-7000                             EDX-7000/8000/8100
                                                    Previous model                       Previous model
                     10000.0
                      1000.0
                      100.0
                       10.0
                        1.0
                                                                                                                                                               Preparation of a Phthalate Ester Standard  Preparation of a Test Sample
                        0.1
                         10  15  20  25  30  35  40  45  50  55  60  65  70  75  80  85 90  10.0  11.0  12.0  13.0                                                                    Sample Preparation Videos
                                        Atomic number
                     Comparison of the Lower Limit of Detection in a Light Element Matrix  Profile Comparison for Lead (Pb) in Copper Alloy   Sample preparation videos: http://www.shimadzu.com/an/gcms/py-screener.html


                    Ultra-Light Element Analysis by EDX-8000/8100                                                                             Easy to Operate Using Special Software
                    The EDX-8000/8100 features an SDD detector with a special ultra-thin-film window material that is able to detect ultra-light   The special software leads you through the required
                    elements such as carbon (C), oxygen (O), and fluorine (F)                                                                 procedures, so even novices can perform the operations in
                                                                                                                                              accordance with the software instructions. The Py and
                                                                                                                                              GC-MS analysis conditions are preset. To automatically
                          LiF                                                                                                                 start continuous analyses, just place the prepared standard
                          CF2                                                                                                                 samples and test samples in the autosampler, and enter
                          CaF2                                                                                                                the number of samples, the sample names, and their
                                                                                                                                              weights. Continuous measurements can be performed                        Measurement Schedule Window
                                                                                                                                              overnight, so approximately 30 samples can be measured
                                                                                                                                              per day.

                                                                                                                                                                                              Special Py-Screener Software



                        Profile of Fluorine (F) by EDX-8000

                                                                                                                                                                                                                                       EDX-LE