Page 15 - Shimadzu EDX-LE
P. 15

Instrument Specifications



 Primary Specifications  Installation Example  Options
 Measurement Principle  X-ray fluorescence spectrometry  Dimensions of the Main Unit  W 520 mm × D 650 mm × H 420 mm  Halogen Screening Analysis Kit  Sample Cells
 Measurement Method  Energy dispersive  Main Unit Weight  Approx. 60 kg  P/N 212-24908-91  3571 General Open-End X-Cell (no lid)
 Measurement Sample Type  Solids, liquids, or powder  This kit includes an instruction manual for Halogen analysis and a check sample required   P/N 219-85000-55 (100 pcs/set)
                    for measurement of 6 elements (Cd, Pb, Hg, Cr, Br, and Cl) specified by the RoHS
 Elements to be Detected  13 Al to  92 U  directive and Halogen regulation.  (Outer diameter: 31.6 mm, volume 10 mL)
 Sample Chamber Size  Max. W 370 mm × D 320 mm × H 155 mm  Unit: mm    Polyethylene sample cell used for liquid and powder samples. Used
                                                                       with Mylar or polypropylene films.
 At least 200 mm between unit and wall
 X-Ray Generator    RoHS, Halogen, and Antimony Screening Analysis Kit  3529 General X-Cell (with lid)
                    P/N 212-24922-91
 X-Ray Tube  Rh target
                    This kit includes an instruction manual and a check sample required for measurement of   P/N 219-85000-52 (100 pcs/set)
 Tube Voltage  5 kV to 50 kV  7 elements including those specified by the RoHS directive, Halogen regulation, and   (Outer diameter: 32 mm, volume 8 mL)
 Tube Current  1  A to 1,000  A  650  Antimony (Cd, Pb, Hg, Cr, Br, Cl, and Sb)  Used for liquid samples. Equipped with relief hole and liquid retainer
 Cooling Method  Air cooling (with fan)                                in case of liquid expansion.
 Exposure Area  Automatic switching between 3, 5, and 10 mm   Small Spot Solder Analysis Kit
 dia. areas (1 mmø is an option)  P/N 212-24850-41                     3577 Micro X-Cell
 Primary Filter  Automatic switching between: 5 types + OPEN  520  (460)  This kit includes an instruction manual for small spot solder analysis and a small spot   P/N 219-85000-54 (100 pcs/set)
                    collimator plate required for measurement of a print circuit board.  (Outer diameter 31.6 mm, volume 0.5 mL)
 Detector                                                              For trace samples. Use with a collimator is recommended to reduce
                                                                       scattered radiation emitted by sample cell.
 Type  Si-PIN semiconductor detector  420  Additional Function Kit for EDX-LE
 LN 2  Supply  Not required
                    P/N 212-24714-42                                   3561 Universal X-Cell
 Counting Method  Digital filter counting  Adds a general-analysis function to the EDX-LE. For details, please contact your
 1800               Shimadzu representative.                           P/N 219-85000-53 (100 pcs/set)
                                                                       (Outer diameter 31.6 mm, volume 8 mL)
 Sample Chamber                                                        For liquid and thin-film samples. Equipped with a relief hole and
 Measurement Atmosphere  Air                                           liquid retainer in case of liquid expansion. Equipped with a ring for
                                                                       tightly holding thin-film samples with film.
 Sample Observation  CCD camera
 Data Processing Unit                                                  Polypropylene Film
                                                                       P/N 219-82019-05 (73 mm W × 92 m roll)
 Memory  1 GB min.
                                                                       Sample-holding film. (For light element analysis)
 HDD  80 GB min.
 Resolution  1024 × 768 pixels min.
 Printer  Color inkjet printer                                         Mylar Film
                                                                       P/N 202-86501-56 (500 sheets/set)
 CD  CD-ROM drive
                                                                       Sample-holding film. (For heavy element analysis)
 OS  Windows 7*
 * Microsoft Office is not included in this OS.
 Software
 Screening Analysis  Simple operation software
 Qualitative Analysis  Measurement/analysis software
 Quantitative Analysis  Calibration curve method
 FP method
 Thin-film FP method (Option)
 BG-FP method (Option)
 Matching Software  Option
 Utilities  Automatic calibration functions (energy
 calibration, full-width half-maximum
 calibration)
 Other Functions  System-status Monitoring Function
 Analysis-results Tabulation Function
 Analysis-results Report Creation Function

 Installation Requirements

 Guaranteed Performance  Guaranteed Operation
 Temperature  10°C to 30°C (fluctuations   5°C to 35°C
 should be 2°C/hour max.)
 Humidity  40% to 70% (No condensation)  40% to 70% (No condensation)
 Power Source  AC 100 V to 240 V ±10% 50/60 Hz, 150 VA grounded outlet
 Power for peripheral devices (printer, PC, display monitor, etc.) must be
 provided separately.











                                                                                                              EDX-LE
 14                                                                                              Energy Dispersive X-ray Fluorescence Spectrometer  15
   10   11   12   13   14   15   16