Page 12 - Shimadzu EDX-LE Plus
P. 12

Proposed Screening Method for RoHS Directive


            Shimadzu offers customers comprehensive assistance in complying with RoHS/ELV requirements. In addition to developing and                                Subject to Revised RoHS Directive
            manufacturing energy-dispersive X-ray  uorescence spectrometers (EDXRF), which account for a large portion of the testing                                 Lead (Pb)
            equipment used for RoHS/ELV directive compliance, Shimadzu also develops and manufactures ICP atomic emission                                             Mercury (Hg)          Py-GC/MS
                                                                                                                                                                                                     ™
            spectrometers (ICP-AES), ICP mass spectrometers (ICP-MS), atomic absorption spectrophotometers (AA), ultraviolet-visible   EDX-7000/8000/8100 EDX-LE Plus  Cadmium (Cd)         (Py-Screener )
                                                                                                                                                                      Hexavalent chromium (Cr6+)
            spectrophotometers (UV-VIS), Fourier transform infrared spectrophotometers (FT-IR), gas chromatograph mass spectrometers                                  PBBs
            (GC-MS), high performance liquid chromatographs (HPLC), and ion chromatographs (IC). Shimadzu develops applications for this                              PBDEs
            equipment and even offers guidance for testing methods.                                                                                                   Phthalate esters
                                                                                                                                                                      (DIBP, DBP, DEHP, BBP)


                                                                                             Polymer materials
                                                                             Yes                                                            Screen by               Py-GC/MS
                                                                                              Electronic parts                           X-ray fluorescence         Screening
                                                                                              (with polymer)
                                                                                                                                                                                                               Pass
                                                         Presence of                                                                                                                           Compare to              Conforming   *2
                                                           polymer                                                                                                                               criteria*1

                                                                                                 Metals                                     Screen by
                                                                                              Electronic parts
                                                                              No                                                         X-ray fluorescence                                            Fail
                                                                                             (without polymer)
                                                           Yes
                                                                                                                                                                                        Yes     Accurate       No
                         Samples                                                                                                                                                              Measurement            Non-conforming   *2
                  Homogeneous substances                                                                                                                                                        Obtained
                          Metals
                     Polymer materials                    Screening
                      Electronic parts                                                                                                                                                                         Pass
              (circuit boards and individual components)                                                                                                                                                               Conforming   *2
                                                           No


                                                                                              Prepare sample                                        Analyze accurately                         Compare to
                                                                                          (mechanically pulverize)                                 (by various methods)                          criteria*1

                                                                                                                                                                                                               Fail
                                                                                                                                                                                                                     Non-conforming   *2
            Substances Restricted by RoHS II and Start Date


                                               Date of Applicability  Date of Applicability  Date of Applicability
             Restricted Substances Max. Allowable Conc.
                                              (Categories 1 to 7 and 10)  (Categories 8 and 9)  (Other Electrical and Electronic Equipment)
                   Lead           0.1%
                                                                         July 22, 2014                                                 AA-7000 Series         ICPE-9800 Series    ICPMS-2030      UVmini-1280       GCMS-QP2020
                  Mercury         0.1%
                                                                   In vitro diagnostic medical devices:
                 Cadmium         0.01%
                                                  July 01, 2006          July 22, 2016          July 22, 2019
             Hexavalent chromium  0.1%
                                                                      Industrial monitoring and
             Brominated  PBB      0.1%                                 control instruments:
               flame                                                     July 22, 2017
             retardants  PBDE     0.1%
                      DEHP        0.1%
                                                                                                                                                                        TM
             Phthalate  BBP       0.1%                                                                                                 IRAffinity-1S           Prominence  HIC-NS/HIC-SP
              esters   DBP        0.1%            July 22, 2019          July 22, 2021          July 22, 2019
                      DIBP        0.1%
             Categories
             1: Large household appliances, 2: Small household appliances, 3: IT and telecommunications equipment, 4: Consumer equipment,                                                      *1: Pass/fail criteria are determined by each organization.
             5: Lighting equipment, 6: Electrical and electronic tools, 7: Toys, leisure and sports equipment, 8: Medical devices,                                                             *2: Conforming and non-conforming refer to conformance/non-conformance
             9: Monitoring and control instruments including industrial monitoring and control instruments, and 10: Automatic dispensers                                                             with the criteria of the organization.

                                                                                                                                                                                                                          EDX-LE Plus
      12                                                                                                                                                                                                            Energy Dispersive X-ray Fluorescence Spectrometer  13