Page 14 - Shimadzu EDX-LE Plus
P. 14

Instrument Speci cations






             Primary Speci cations                               Installation Example                                                  Options

             Measurement Principle  X-ray  uorescence spectrometry  Dimensions of the Main Unit  W 520 mm × D 650 mm × H 420 mm       Halogen Screening Analysis Kit                     Sample Cells
             Measurement Method  Energy dispersive              Main Unit Weight   Approx. 60 kg                                      212-26325-41                                       3571 General Open-Ended X-Cell  (no lid)
                                                                                                                                                                                                                   ™
             Measurement Sample Type  Solid, liquid, or powder                                                                        This kit includes an instruction manual for Halogen analysis and a   P/N 219-85000-55 (100 pcs/set)
             Elements to be Detected  13 Al to  92 U                                                       Unit: mm                   check sample required for measurement of 6 elements (Cd, Pb, Hg, Cr,   (Outer diameter: 31.6 mm, volume 10 mL)
                                                                                                                                      Br, and Cl) specified by the RoHS directive and Halogen regulation.
             Sample Chamber Size  Max. W 370 mm × D 320 mm × H 155 mm                  At least 200 mm between unit and wall                                                             Polyethylene sample cell used for liquid and powder
                                                                                                                                                                                         samples. Used with PET or polypropylene  lms.
            X-Ray Generator                                                                                                           RoHS, Halogen, and Antimony Screening Analysis Kit
             X-Ray Tube         Rh target                                                                                             212-26326-41
             Tube Voltage       5 kV to 50 kV                                                                                         This kit includes an instruction manual and a check sample required   3577 Micro X-Cell
             Tube Current       1  A to 1,000  A                        650                                                           for measurement of 7 elements including antimony and elements   P/N 219-85000-54 (100 pcs/set)
             Cooling Method     Air cooling (with fan)                                                                                specified in the RoHS directive and halogen regulations. (Cd, Pb, Hg,   (Outer diameter 31.6 mm, volume 0.5 mL)
                                                                                                                                      Cr, Br, Cl, and Sb.)
             Exposure Area      Automatic switching between 1, 3, 5, and                                                                                                                 For trace samples. Use with a collimator is
                                10 mm dia. areas                                                                                                                                         recommended to reduce scattered radiation emitted
             Primary Filter     Automatic switching between: 5 types + OPEN                  (380)
                                                                                  520                                                                                                    by the sample cell.
            Detector                                                                                                                                                                     3561 Universal X-Cell
             Type               Silicon-drift detector (SDD)                                                                                                                             P/N 219-85000-53 (100 pcs/set)
             LN 2  Supply       Not required                            420                                                                                                              (Outer diameter 31.6 mm, volume 8 mL)
             Counting Method    Digital  lter counting                                                                                                                                   For liquid and thin- lm samples. Equipped with a
                                                                                                                                                                                         relief hole and liquid retainer in case of liquid
            Sample Chamber                                                            1200                                                                                               expansion. Equipped with a ring for tightly holding
                                                                                                                                                                                         thin- lm samples with  lm.
             Measurement Atmosphere  Air                                          EDX-LE Plus
             Sample Observation  CCD camera
                                                                                                                                                                                         Polypropylene Film
                                                                                                                                                                                         P/N 219-82019-05 (73 mm W × 92 m roll)
            Data Processing Unit                                                                                                                                                         Sample-holding  lm. (For light element analysis)
             Memory             2 GB min. (32-bit), 4GB min. (64-bit)
             HDD                240 GB min.                                                                                                                                              PET Film
             Resolution         1024 × 768 pixels min.                                                                                                                                   P/N 202-86501-56 (500 sheets/set)
             CD                 CD-ROM drive                                                                                                                                             Sample-holding  lm. (For heavy element analysis)
             OS                 Windows  10 (32-bit/64-bit)*
                                     ®
            * Microsoft Of ce is not included in this OS.
                                                                                                                                      RoHS Compliance Screening Analysis Instruments
            Software
             Screening Analysis  Simple operation software                                                                            Screening System for Phthalate Esters                Energy Dispersive X-ray Fluorescence Spectrometer
             Qualitative Analysis  Measurement/analysis software                                                                      Py-Screener                                          EDX-7000/8000/8100
             Quantitative Analysis  Calibration curve method,FP method,
                                Thin- lm FP method
             Utilities          Energy Check, Control Analysis
             Other Functions    System Status Monitoring Function
                                Analysis Results Tabulation Function
                                Analysis Results Report Creation Function




                                                                                                                                                                                           • High Sensitivity, High Speed, and High Resolution
                                                                                                                                                                                            High speed, high sensitivity, and high resolution SDD detector and
             Installation Requirements                                                                                                                                                      optimized hardware achieve the highest level of analysis performance in
                                                                                                                                                                                            the series.
                        Guaranteed Performance  Guaranteed Operation
             Temperature  10°C to 30°C ( uctuations   5°C to 35°C                                                                     This system is designed for screening for phthalate esters in polymers. The   • Accommodates Various Types and Sizes of Samples
                      should be 2°C/hour max.)                                                                                        use of phthalate esters is restricted in toys, food packaging etc. They are      EDX-7000/8000/8100:
             Humidity  40% to 70% (No condensation)  40% to 70% (No condensation)                                                     expected to be regulated as restricted substances under the RoHS (II)        The combination of Small Spot Analysis Kit and EDXIR-Analysis TM
             Power Source  AC 100 V to 240 V ±10% 50/60 Hz, 150 VA grounded outlet                                                    Directive.                                                Software facilitate contaminant analysis.
                      Power for peripheral devices (printer, PC, display monitor, etc.) must be                                       The system supports a series of procedures from sample preparation to data        Turret for 12 samples permits continuous measurement.
                      provided separately.                                                                                            acquisition, analysis, and maintenance. It consists of special software, special      EDX-7000/8100:
                                                                                                                                      standard samples, and a sampling toolkit. It is easy to operate, even for   Vacuum Measurement Unit (also accommodates EDX-8000) and Helium
                                                                                                                                      novices.                                              Purge Unit enable the analysis of liquid, powder and solid samples.
                                                                                                                                                                                              EDX-8000/8100:
                                                                                                                                                                                                The detector has a wide range and can detect elements from C to U.
                                                                                                                                                                                            PCEDX-Navi software makes RoHS-directive-restricted material analysis
                                                                                                                                                                                            and report creation easy even for beginners.


                                                                                                                                                                                                                          EDX-LE Plus