Instrument Speci cations






 Primary Speci cations  Installation Example  Options

 Measurement Principle  X-ray  uorescence spectrometry  Dimensions of the Main Unit  W 520 mm × D 650 mm × H 420 mm  Halogen Screening Analysis Kit  Sample Cells
 Measurement Method  Energy dispersive  Main Unit Weight  Approx. 60 kg  212-26325-41  3571 General Open-Ended X-Cell  (no lid)
                                                                                          ™
 Measurement Sample Type  Solid, liquid, or powder  This kit includes an instruction manual for Halogen analysis and a   P/N 219-85000-55 (100 pcs/set)
 Elements to be Detected  13 Al to  92 U  Unit: mm  check sample required for measurement of 6 elements (Cd, Pb, Hg, Cr,   (Outer diameter: 31.6 mm, volume 10 mL)
            Br, and Cl) specified by the RoHS directive and Halogen regulation.
 Sample Chamber Size  Max. W 370 mm × D 320 mm × H 155 mm  At least 200 mm between unit and wall  Polyethylene sample cell used for liquid and powder
                                                               samples. Used with PET or polypropylene  lms.
 X-Ray Generator  RoHS, Halogen, and Antimony Screening Analysis Kit
 X-Ray Tube  Rh target  212-26326-41
 Tube Voltage  5 kV to 50 kV  This kit includes an instruction manual and a check sample required   3577 Micro X-Cell
 Tube Current  1  A to 1,000  A  650  for measurement of 7 elements including antimony and elements   P/N 219-85000-54 (100 pcs/set)
 Cooling Method  Air cooling (with fan)  specified in the RoHS directive and halogen regulations. (Cd, Pb, Hg,   (Outer diameter 31.6 mm, volume 0.5 mL)
            Cr, Br, Cl, and Sb.)
 Exposure Area  Automatic switching between 1, 3, 5, and       For trace samples. Use with a collimator is
 10 mm dia. areas                                              recommended to reduce scattered radiation emitted
 Primary Filter  Automatic switching between: 5 types + OPEN  (380)
 520                                                           by the sample cell.
 Detector                                                      3561 Universal X-Cell
 Type  Silicon-drift detector (SDD)                            P/N 219-85000-53 (100 pcs/set)
 LN 2  Supply  Not required  420                               (Outer diameter 31.6 mm, volume 8 mL)
 Counting Method  Digital  lter counting                       For liquid and thin- lm samples. Equipped with a
                                                               relief hole and liquid retainer in case of liquid
 Sample Chamber  1200                                          expansion. Equipped with a ring for tightly holding
                                                               thin- lm samples with  lm.
 Measurement Atmosphere  Air  EDX-LE Plus
 Sample Observation  CCD camera
                                                               Polypropylene Film
                                                               P/N 219-82019-05 (73 mm W × 92 m roll)
 Data Processing Unit                                          Sample-holding  lm. (For light element analysis)
 Memory  2 GB min. (32-bit), 4GB min. (64-bit)
 HDD  240 GB min.                                              PET Film
 Resolution  1024 × 768 pixels min.                            P/N 202-86501-56 (500 sheets/set)
 CD  CD-ROM drive                                              Sample-holding  lm. (For heavy element analysis)
 OS  Windows  10 (32-bit/64-bit)*
 ®
 * Microsoft Of ce is not included in this OS.
            RoHS Compliance Screening Analysis Instruments
 Software
 Screening Analysis  Simple operation software  Screening System for Phthalate Esters  Energy Dispersive X-ray Fluorescence Spectrometer
 Qualitative Analysis  Measurement/analysis software  Py-Screener  EDX-7000/8000/8100
 Quantitative Analysis  Calibration curve method,FP method,
 Thin- lm FP method
 Utilities  Energy Check, Control Analysis
 Other Functions  System Status Monitoring Function
 Analysis Results Tabulation Function
 Analysis Results Report Creation Function




                                                                 • High Sensitivity, High Speed, and High Resolution
                                                                  High speed, high sensitivity, and high resolution SDD detector and
 Installation Requirements                                        optimized hardware achieve the highest level of analysis performance in
                                                                  the series.
 Guaranteed Performance  Guaranteed Operation
 Temperature  10°C to 30°C ( uctuations   5°C to 35°C  This system is designed for screening for phthalate esters in polymers. The   • Accommodates Various Types and Sizes of Samples
 should be 2°C/hour max.)  use of phthalate esters is restricted in toys, food packaging etc. They are      EDX-7000/8000/8100:
 Humidity  40% to 70% (No condensation)  40% to 70% (No condensation)  expected to be regulated as restricted substances under the RoHS (II)        The combination of Small Spot Analysis Kit and EDXIR-Analysis TM
 Power Source  AC 100 V to 240 V ±10% 50/60 Hz, 150 VA grounded outlet  Directive.       Software facilitate contaminant analysis.
 Power for peripheral devices (printer, PC, display monitor, etc.) must be   The system supports a series of procedures from sample preparation to data        Turret for 12 samples permits continuous measurement.
 provided separately.  acquisition, analysis, and maintenance. It consists of special software, special      EDX-7000/8100:
            standard samples, and a sampling toolkit. It is easy to operate, even for   Vacuum Measurement Unit (also accommodates EDX-8000) and Helium
            novices.                                               Purge Unit enable the analysis of liquid, powder and solid samples.
                                                                    EDX-8000/8100:
                                                                      The detector has a wide range and can detect elements from C to U.
                                                                   PCEDX-Navi software makes RoHS-directive-restricted material analysis
                                                                   and report creation easy even for beginners.


                                                                                                EDX-LE Plus
 14                                                                                       Energy Dispersive X-ray Fluorescence Spectrometer  15
   10   11   12   13   14   15   16