Differential Scanning Calorimeter  DSC  DSC-60A Plus Automatic Differential   Specialized Tray
            Scanning Calorimeter Capable of
 DSC-60 Plus Series  Continuous Unattended Measurement
            The built-in compact autosampler permits automated measurement, analysis,
            and report printout for up to 24 loaded samples. It improves the ef ciency of
 DSC-60 Plus addresses the various DSC applications.  screening during product development and the ef ciency of quality control
            activities.
 The DSC-60 Plus is an indispensable thermal analyzer for materials characterization in
 R&D and quality control applications in such areas as polymers, pharmaceuticals,   Specifications
 electronic parts , foods , etc . It offers the sensitivity and easy operation required for the   DSC-60 Plus  DSC-60A Plus
 development of high-performance, highly functional new materials.   Measurement principle  Heat- ux type
             Temperature range      −140~600°C (With standard cooling chamber and using liquid nitrogen)
             Calorimetric measurement range        ±150mW
             Noise level                Less than 0.5µW (RMS, when held at 150°C)
 High-sensitivity analysis across the entire measured temperature range  Atmosphere  Nitrogen, inert gas, dry air gas  ow
 The new detector and furnace unit of the DSC-60 Plus series assure a stable baseline throughout the entire range of temperatures measured (-140 to 600 °C).   Autosampler  ─  24 samples/tray
 Throughout the broad range of temperatures from extremely low to high, necessary in order to evaluate a wide variety of materials, complicated changes in the   Size  W 320 × D 500 × H 290 mm
 calorimetric value are accurately detected. This allows a DSC to offer high sensitivity and high resolution. The range of calorimetric values measured has been   Weight  28kg  31kg
 expanded nearly threefold (compared with previous Shimadzu models) to ±150 mW. As a result, a dynamic range that is quite suf cient even for evaluations of the   Power supply  AC100V, 120V, 230V 50/60Hz MAX 800VA
 reactions of chemical substances exhibiting large calorimetric changes is now secured.
                                                          Detailed brochure C160-E013
 DSC  DSC
 mW  mW
 100.00
 Sample weight : 11.570[mg]  Sample weight : 45.450[mg]  135.0゚C  Temperature Modulated DSC (TM-DSC)
 2.00
 80.00      By overlaying temperature-modulated results onto results obtained by increasing the temperature at a constant rate, TM-DSC can easily measure speci c heat, or can
 1.00
            measure multiple phenomena that could not be separated using standard DSC systems.
 0.00  −34.2゚C  60.00  If glass transitions, enthalpy relaxations, and other reactions overlap, separation is impossible with standard DSC measurements. Using TM-DSC, however, enables
            separation of these phenomena.
 −1.00  40.00                                                                                                Cp
            DSC (mW)                               DSC (mW)                       DSC (mW)                   J/g.K
 189.15J/g                                         0.50                           2.00                       1.80
 −2.00
 20.00
                                                                                      Speci c heat
                                                      DSC (total)                                            1.60
 −100.0  −50.0  0.0  50.0  100.0  50.0  100.0  150.0  200.0
 Temp [℃]  Temp[℃]                                               80.37˚C          1.00                       1.40
 Glass Transition of NBR Rubber  Adhesive Hardening Reaction  0.00  DSC (reversing)  78.19˚C  DSC (total)
                  Measurement results
                                                                                                             1.20
 DSC  DSC                                             DSC (non-reversing)
 mW  mW                       Temp (℃)                                           -0.00                       1.00
 0.10               Separation
 Sample weight : 1.150[mg]                                       80.06˚C
                                                   -0.50                                                     0.80
 1.00  176.3℃  DSC (mW)                               40.00  60.00  80.0  100.0  120.0  -0.00  1.00  2.00  3.00  4.00
                                                                 Temp[˚C]                      Time[hour]
 145.0℃  −41.91J/g                                     Separation of the Heat Flow for  Quasi-Isothermal Measurements of
 0.00  0.00                     DSC (total)
 75.1 °C                                                Impact-Resistant Polystyrene   an Epoxy Resin Adhesive
                                DSC (reversing)
 −1.00  337.4℃
                                DSC (non-reversing)
 −0.10
 40.00  60.00  80.00  100.00  100.0  200.0  300.0  400.0
 Temp [°C]  Temp [℃]         Temp (℃)
 Denaturation measurement of low-concentration proteins  Measurement of Engineering Plastic (PEEK)
            Options
              Liquid Nitrogen Auto-cooling System TAC-60L        Electric Auto-cooling Attachment TAC-60i
            Consecutive Measurement with liquid nitorogen is enabled at a temperature   Consecutive measurement at a temperature from -50 to 500°C is enabled by
 Structure of the DSC-60 Plus Furnace  from -130 to 500°C . the cooling capacity is -10°C/min. (at -80°C). The tank   connecting a commercially available immersion cooler. Since this cooling system
            internal pressure is optimally controlled according to the residual amount of   does not use liquid nitrogen, it can be easily and safely operated. Using this
 Newly designed the
 The new detector and new unique furnace construction achieves a noise level of   thermal resistance  Liquid nitrogen  liquid nitrogen in the tank to keep the supply  ow rate constant. Pulsation is   cooling system together with the DSC-60A Plus enables automatic cooling
 less than 0.5 W, ensuring a stable baseline.  in these parts.  reduced, and the DSC baseline remains stable even during cooling   measurement.
 A stable baseline and S/N performance enable the detection of a minute   measurement.  * Does not include an intracooler
                                                               * Requires a separate FC-60A controller
 calorimetric change during trace analysis.  Heater  *Requires a separate FC-60A controller
 Heat transfer plate
 Cooling fans
 Thermo-uniformity
 plate
 Improved the temperature  Heat radiating  ns
 distribution around the heater.

                                                                                                        60 Series
 2                                                                                                 Thermal Analysis Instruments  3
   1   2   3   4   5   6   7   8