Page 9 - Shimadzu AIRsight
P. 9

AIRsight
               AIRsight Features for                                    Illustration of Infrared and Raman Light Paths

 Characteristic Features  Raman Measurements


                                                               Confocal optical system used
                                                             Enables Raman measurements with excellent spatial resolution

                                                               Equipped standard with 532 nm and 785 nm lasers
                                                             Characteristics of the lasers
                                                             532 nm : Light scatters more easily, making it easier to obtain
                                                             peak intensities.
                                                             785 nm : Less affected by  uorescence, making it more suitable
                                                             for  uorescent samples.
 Same position  Both FTIR and Raman Spectra Can Be
                                                               Systems can be equipped with either
 is measured by IR and Raman  Measured without Moving Samples  a 50× or 100× objective lens (or both)
                                                             Selectable depending on the target measurement area
 Because samples do not need to be moved, both infrared and Raman spectra can
 be measured from the same position in an extremely small area. That means   Includes XYZ correction for lens switching
 information about both organic and inorganic substances can be obtained from the   between infrared and Raman measurements
 same position, which can signi cantly improve the accuracy of qualitative analysis.  Enables both infrared and Raman measurements from the same
 In addition, Shimadzu’s proprietary wide-view camera and microscope camera (for   location.
 infrared measurements) or objective lens (for Raman measurements) help improve
 sample observation ef ciency. The wide-view camera not only enables observation
 of large areas up to 10 × 13 mm, but it also supports variable digital zooming.   Length Measurement Function
 Furthermore, it shares positional information with the microscope camera and
 objective lenses.
 The microscope camera can be used to observe areas as small as 30 × 40  m, the   AMsolution software now includes
 50× objective lens to observe areas as small as 15 × 20  m, and the 100× objective   functionality for measuring
 lens to observe extremely small areas as small as 7.5 × 10  m.  lengths, including the lengths of
               objects in infrared Raman
               microscope images. Also, length
               measurement results can be output
 Smart software  with a single button click.
 controls IR and Raman
 One Software to Measure and
 Analyze Both FTIR and Raman Spectra
 IR
 You can easily switch between infrared and Raman measurements with a click. In
 addition, infrared and Raman spectra can be superimposed and displayed, and
 various analyses can be performed.
 Raman         Depth                                                                Line Axis
               Measurements                                                     Depth  Sample surface





 Single system
 Obtain Organic and Inorganic Information   Enables Analysis in the                  Sample interior
 saves space
 with One Instrument  Depth Direction (Z-Direction)                                                5 µm

 Infrared microscopes can analyze organic substances, but it is dif cult to obtain   Example of Depth Measurements (at Line)
 information for many inorganic substances.
 On the other hand, Raman microscopes can obtain information about inorganic   Raman measurements can measure depth either at a single point or along a line*. If a transparent sample, such as
 substances such as titanium oxide and carbon, in addition to organic substances.  plastic or glass, has a thickness (depth) dimension, the laser light components that can penetrate the sample can
 In contrast, a single AIRsight unit can analyze mixtures of both organic and   be used to measure the sample interior. Even if the sample is colored or cloudy, measurements are generally
 space  inorganic substances.  possible as long as the interior can be observed.
               * Measuring depth (at a line) requires using a separate mapping program (P/N 206-35093-41).