Page 8 - Shimadzu AIM-9000
P. 8
Automatic Automatic
Contaminant Qualitative
Recognition Analysis
Wide-Field High
Camera Finally, a wide view Sensitivity
on micro sample analysis
Accessories
Contaminant Micro
Analysis Surface Analysis
Analysis
ATR Objective (slide-on type) Ge prism: P/N 206-32600-41 DLATGS Detector P/N 206-32580-41
The ATR objective uses a cone-type prism, with single reflection, 15× magnification and a 45-degree incident angle. The By adding this DLATGS detector to an AIM-9000 infrared microscope,
DLATGS detector
slide-on type prism makes it easy to switch back and forth between visible observation and infrared measurement. This ATR infrared spectra can be obtained without liquid nitrogen. It is also MCT detector
objective is especially effective in analyzing samples that do not transmit or reflect infrared light easily, such as paper and possible to switch back and forth between the MCT and DLATGS
plastics, or extremely thin film, such as stains. detectors for measurements as needed. The DLATGS detector offers a
Abs
-1
wider wavenumber range (up to 400 cm ) than the MCT detector, but
Accretion with lower sensitivity. Therefore, the MCT detector is used to measure
Fiber
micro samples less than 100 µm.
4000 3000 2000 1500 1000 500 cm -1
Abs The infrared spectra of polyvinyl chloride (PVC)
Diamond Cell CII P/N 208-92289-01
4000 3000 2000 1500 1000 cm -1 This diamond compression cell is used to
compress micro samples very thin for
Spectra of contaminants on a textile identified as Phenolic resin
direct measurement under the
microscope. It can be used for samples After rolling
such as plastics and fibers. This CII cell Before rolling
ATR Pressure Sensor P/N 206-32603-41 features a large thin window plate made
of artificial diamond (1.6 mm diameter). Abs
This pressure sensor prevents prism damage due to excessive pressures applied
A type-B cell that uses natural diamond is
during ATR measurements using an ATR objective. It can also be used to
also available.
automate ATR measurement with pressure sensing.
4000 3000 2000 1500 1000 cm -1
The infrared spectra of a single fiber
Grazing Angle Objective (GAO) P/N 206-32602-41 Micro Vise Holder P/N 206-33293
The Grazing angle objective with 80-degree incident angle is effective for measurement of organic thin film with nm level on This holds various types of samples for microscopy. It ensures positive holding of samples of a difficult shape or measurement of a
metal substrate. In the case of failure analysis, this objective is useful for measurement of samples on concave surfaces or sample at a user-selectable angle. Measurement with a polarizer, with the sample under tensile load, provides information on the
stains on a metal surface. molecular orientation.
Microscope image using the visible polarizer
Grazing angle objective (GAO) Infrared Polarizer P/N 206-32605-41
Cassegrain objective
This accessory is useful for researching the orientation characteristics of samples, or increasing sensitivity with Grazing Angle
Objective measurements. The infrared polarizer can be used by inserting it into the microscope from the side.
Abs
Visible Polarizer P/N 206-32540-41
This accessory is useful for visible observation of samples that are normally difficult to observe using visible light. Using the
4000 3000 2000 1500 1000 cm -1 properties of polarized light can make samples easier to see.
The infrared spectra of stains on the metal (oil film)
8 9