Page 11 - GCMS-QP2050
P. 11

One Instrument, Infinite Possibilities







 Conquering Helium Shortages  A Flexible Fit for Laboratories




 Minimizing the Usage of Helium Gas  Remote System Access

 Using the included carrier gas save function makes it possible to reduce the amount of carrier gas used during analysis.   The system can be operated from a personal
 Additionally, with the optional gas selector, the carrier gas can be switched from helium to nitrogen except during   computer or tablet on the network via a LAN
 analysis, thereby minimizing helium gas consumption during standby.  connection. Additionally, analysis and
               instrument status can be checked while away
               from the laboratory.
 2500

 During analysis  2000
 1500
 Gas(Main)  Volume of Helium Consumption (mL)  1000


 reduction
 When not analyzing  500 0  Approx.  90%  Compact Design Fits Anywhere
 Unused  Combined use of the carrier gas
 Gas(Sub)
 save function and the gas selector



 Reliable Operation with Alternative Carrier Gases

                                   Conventional model
 Hydrogen and nitrogen, which cost less and are easier to acquire, can be used as the carrier gas. With its high-perfor-
 mance flow controller and a design that reduces the impact of the carrier gas, the GCMS-QP2050 can perform stable
 measurements using either gas without modifying the instrument configuration.

                                   Approx. 1,500 mm                                 Approx. 630 mm
 Hydrogen gas sensor  60
 Average Linear Speed (cm/sec)  40  Constant flow speed

 N2  50  Constant flowrate  The GCMS-QP2050 saves on space. Thanks to remote access, there is no need to install a personal computer beside the
              instrument. This enables a flexible layout in the laboratory.
 HETP
 He
 H2  30  Constant pressure
 0  20  40  60  80  20  40  90  140  190  240  290  340  390
 Average Linear Velocity (cm/sec)  Column Temperature (°C)
                                                         Energy Savings               This product is certified as
                 100                                                                  Shimadzu's Eco-Products Plus.
 Hydrogen Carrier Gas  Nitrogen Carrier Gas  80

 Hydrogen is the first choice as an alternative carrier gas from the   The GCMS-QP2050 demonstrates its true value   60  The GCMS-QP2050 is equipped with ecology mode, which can
 perspective of sensitivity and separation. By installing the   when nitrogen is used as the carrier gas. In   Power Consumption (%)  reduce power consumption. It is also recognized as
                                64%
 optional hydrogen sensor, if a leak occurs, the system   constant linear velocity mode, the system   40  energy savings  Eco-Products Plus, Shimadzu’s proprietary recognition of
 automatically switches to safe standby mode, adding a level of   achieves separation on par with helium when   20  environmentally friendly products. In addition to limiting
 comfort to anyone concerned about using hydrogen.  using nitrogen, which has a narrow range of   analysis running costs, CO2 emissions are limited, thereby
                  0
 optimal linear velocities.  Without ecology mode  With ecology mode  contributing to a carbon-free society.



 10                                                                                                               11
   6   7   8   9   10   11   12   13   14   15   16