Surprisingly simple

 Positive/negative polarity switching opens possibilities for   Effortless operation and reliable results
 new applications



               Easy to switch between CID and OAD
 Shimadzu's breakthrough innovation challenges the common belief that TOF instruments cannot undergo
 efficient polarity switching. With the capability to achieve low-ppm mass measurement accuracies in short   CID is also possible with the OAD RADICAL SOURCE I
 switching intervals, possibilities are now open to enhance the workflow with greater confidence and ease.
               installed. No special software is required, and
               LabSolutions  LCMS control and analysis software for
                        ™
               LCMS-9050 can easily switch between OAD and CID for
 Achieving both polarity switching and  analysis. Acquisition of a large amount of structural
 Mass accuracy  information by OAD and CID can lead to new discoveries
               in lipids and other organic compounds.
 Measure  Measure  Measure  Measure  Measure  The LCMS-9050 features a proprietary
 Positive  Negative  Positive  Negative  Positive
 ions  ions  ions  ions  ions  high-precision electrical circuit and the
 UFstabilization  algorithm (patent
 ™
 Switch  Switch  Switch  Switch                                                                     [M + H] +
 polarity  polarity  polarity  polarity  Reliable structure estimation with
 pending) that make polarity switching                                                            687.5537
 Illustration of Switching between  both fast and stable.  high mass accuracy
 Positive and Negative Ion Modes
                                                                        ∆m/z < 3 ppm
               The high mass accuracy achieved with the LCMS-9050
                                                                           n-9
               remains unchanged even with OAD. High-quality MS/MS        591.4231
                                                                                 O                 CH3
 Increasing workflow efficiency with polarity switching  data within ±3 ppm enables reliable structure estimation   O  O  CH3
                                                                                  O
               of compounds, including determination of the position             O   CH3  TG 18:1 (n-9)_16:0_4:0
                                                                                  O
 Analysis that was previously performed twice in positive ion mode and negative ion mode can now be   of carbon-carbon double bonds.
 performed in one analysis, improving the analysis throughput. In addition, positive and negative ions can be
                                                                   560  580   600  620  640   660  680  m/z
 detected in the pretreated sample under the same conditions without any time lag, improving the reliability
 of the analytical data.
 100  25.0
 [M + H] +
 90  782.5688  22.5
 255.2325   C16:0
 80  20.0
 ×20
 70  17.5  303.2326   C20:4
 688.4541
 60  n-9  15.0
 648.4224  728.4868
 %  50  n-12  n-6  %  12.5
 40  608.3912  10.0
 184.0732  n-15
 30  7.5
 20  Fragment ions derived from  5.0
 the polar group
 10  2.5
 0  0.0
 200  300  400  500  600  700  800  m/z  200  300  400  500  600  700  800  m/z
 Positive Ion Mode Measurement (OAD)  Negative Ion Mode Measurement (CID)


 PC (36:4) and other lipids were detected in
 O  O
 +  O  P  O  O  mouse liver samples in both positive ion and
 N
 O  H  O  negative ion modes. Taking measurements in
 O  both positive ion and negative ion modes
 enables more accurate structural estimates of
 compounds.