Page 91 - Application Handbook - Liquid Chromatography
P. 91

SCA_280_081







                                           High Performance Liquid Chromatography

                                           Analysis of amoxicillin and cefotaxime

             No. SCA_190_022


            Alban Huteau, Shimadzu France SAS.

            Introduction                                        Analytical Conditions:

            Amoxicillin, is an antibiotic useful for the treatment   System configuration:
            of a number of bacterial infections. It is the first line
            treatment for middle ear infections. It may also be   A Shimadzu Nexera X2 UHPLC system was used
            used for strep throat, pneumonia, skin infections,   consisting of two quaternary solvent pumps (LC-
            and  urinary  tract  infections  among  others.  It  is   30AD)  with two 5 channel degassers (DGU-
            taken by mouth.                                     20A5R), an autosampler (SIL-30AC), and a column
            Cefotaxime is a third-generation cephalosporin anti-  oven (CTO-20AC). The system was also equipped
            biotic. Like other third-generation cephalosporins,   with an SPD-M30A photo diode array detector.
            cefotaxime is a broad-spectrum antibiotic  with
            activity against numerous Gram-positive and         Analytical Method:
            Gram-negative bacteria. Developed by Hoechst-
            Roussel Pharmaceuticals in the late 1980s, it was   Column:       Kinetex C18, 100 x 2.1 mm 2.6 µm
            among  the  first  third-generation  ("extended     Mobile Phase:   A: H2O + 2 mM CH3COONH4;
            spectrum") cephalosporins and the first of its class              B: MeOH + 0.1% FA
            to become available in the United States. It is on   Gradient:    10 % B (0-0.5 min); 95 % B
            the World Health Organization's  List of Essential                (4-6.5 min); 10 % B (6.8-10 min)
            Medicines, the most important medications needed    Flow rate:    0.4 mL/min
            in a basic health system.                           Temperature:  30 °C
                                                                Injection Volume: 0.5 µL
                                                                Detector:     SPD-M30A, standard cell,
                                                                              sampling rate 12.5 Hz, time
            Chromatogram                                                      constant 0.160 sec, slit width 8 nm














            Conclusion /Result

            A  fast,  selective,  and  sensitive  method  for  the   Very good results were also obtained in deviation
            analysis  of amoxicillin  and cefotaxime was        and accuracy  and for the calibration curve a
            developed.                                          correlation coefficient from >0.999 was achieved.
   86   87   88   89   90   91   92   93   94   95   96