Page 58 - Pharmaceutical- Guide to Biopharmaceutical
P. 58

Others


                     TORAST-H Series





                     Shimadzu original low adsorption glass vial                                                                        Shimadzu original low adsorption


                     TORAST-H Glass Vial                                                                                                polypropylene vial                                                                                   Cell Line Optimization
                                                                                                                                        TORAST-H Bio Vial






                                benefits                                                                                                                   benefits                                                                          Culture



                     •   Low adsorption glass vial suitable for long-term storage.                                                              •   Extremely low adsorption of peptides
                     •   Minimized adsorption of bases, acids and neutrals                                                                      •   Extremely low adsorption of basic compounds
                     •    Superior quality control                                                                                              •   User-friendly design



                     Adsorption Test for Long-term Storage                                                                              Adsorption Test Using Trypsin Digestion Products of Myoglobin (approx. 1.9 pmol/mL)                  Purification
                     When a sample is stored in a general vial for a long time, the sample may adsorb into the surface of the vial, causing the reproducibility to be poor.   The results confirmed the phenomenon that highly polar peptides with retention times detected between approx. 7 and 8 minutes mostly adsorb to glass
                     The TORAST-H Glass Vial contains low adsorption characteristics that makes it excellent for long-term sample storage.  vials, whereas highly hydrophobic peptides with retention times detected between approx. 12 and 16 minutes mostly adsorb to polypropylene (PP) vials.

                                                                                                                                                            TORAST-H Bio vials    Glass vials      Polypropylene (PP) vials
                                 Basic Compounds A (log P 4.5, pKa 10.5)                                                                                                                              Adsorption especially
                                                                                                                                                                        Adsorption to glass vials
                                                                                                                                                                                                      to PP and glass vials                  Characterization

                       Recovery (%)                        Glass Vial A  Glass Vial A


                                                                        Glass Vial B
                                                                        Glass Vial C
                                                           Glass Vial B
                                                           Glass Vial C                                                                                                                                                                      Quality Control


                     Note: The area at time 0 of the PP vial (Controls) was set at 100 %.
                              After 3 months, the recovery rate of PP vials was 89 %, which was lower than that of TORAST-H Glass Vial.  Exterior Design that Enables Using Vials Directly for Flash Centrifugation
                                                                                                                                                                                        Centrifuge

                             Product            Details       Cap      Slit    Volume    Qty.        P/N
                                                                                                                                                                  Droplets
                                          Clear glass with a label     No                         370-04300-01                                                   Sample loss
                                          (wide diameter 9-425)        Yes                        370-04300-02                                                                                                                               Pharmacokinetics
                                                                               1.5 mL
                                          Amber glass with a label     No                         370-04300-03                                               Air entrainment
                      TORAST-H Glass Vial  (wide diameter 9-425)       Yes                        370-04300-04                                           Prevents specified injection
                      (Includes the quality certificate
                      and PTFE/Silicone septum)  Clear glass with a label   Screw, Black  No  100  370-04301-01
                                          (wide diameter 9-425)        Yes                        370-04301-02
                                                                               150 µL                                                             Product              Details        Slit     Volume     Qty.          P/N
                                          Amber glass with a label     No                         370-04301-03
                                          (wide diameter 9-425)        Yes                        370-04301-04                            TORAST-H Bio Vial     PP vial               Yes      300 µL     100        370-04350-00            Others
                      Screw Cap for       PTFE/Silicone septum         No                         370-04310-01                                    If using a Shimadzu i-Series LC system, use the special vial detection plate (P/N: 228-51891-03) shown to the right.
                      TORAST-H Glass Vial  (wide diameter 9-425)       Yes      -                 370-04310-02



        58                                                                                                                                                                                                                                  59
                                                                                                            index                                                                                                                  index
   53   54   55   56   57   58   59   60   61   62   63