Page 4 - Solution SystemGC for Hydrocarbon
P. 4

GC-2030                                                                       Intelligent Flow Controller with Exceptional Reproducibility


                                                                                                                                      A new advanced flow controller (AFC) has been developed to include a   Results from Analyzing a Grob Test Mix  Split filter
            5IF /FYU *OEVTUSZ 4UBOEBSE                                                                                                CPU.                                                     Standard Ten Consecutive Times
                                                                                                                                      It supports carrier gas constant linear velocity control, constant flowrate
                                                                                                                                                                                                     Peak Area Value
                                                                                                                                                                                                               Retention Time
                                                                                                                                      control, constant pressure control, and various other control modes and  RSD%  RSD%
                                                                                                                                      achieves exceptionally high reproducibility for ultra-high-speed and  Decane  0.29  0.005
                                                                                                                                                                                          1-Octanol     0.32      0.004
                                                                                                                                      ultra-high-precision control modes. Multi-step programs can be created
                                                                                                                                                                                          Undecane      0.28      0.004
                                                                                                                                      for each control mode as well.                      2,6-dimetylaniline  0.29  0.003
                                                                                                                                      The split line filter can be replaced with hands. Internal contamination can  n-Metyl Nonanoate  0.24  0.003
            Nexis GC-2030, Shimadzu's premier gas                                                                                     be confirmed visually to ensure filters are replaced at the proper timing.  n-Metyl Decanoate  0.25  0.002
                                                                                                                                                                                                        0.23
                                                                                                                                                                                                                  0.003
                                                                                                                                                                                          Dicyclohexylamine
            chromatograph, offers a modern approach to                                                                                                                                    n-Metyl Laurate  0.27   0.004            Valve
                                                                                                                                                                                                                              Flow Controller
            a classic chromatographic technique. Designed                                                                             GC Systems Customized for Speci c Needs                                                  (AFC-2030)
            with the user in mind, new innovative
            features, exceptional performance and high                                                                                                  Gasoline analysis system                  Natural gas analysis system
            throughput capabilities will elevate your lab to                                                                                            This system is able to measure            This system is able to analyze
            the next level.                                                                                                                             specific substances in gasoline,          components in natural gas, such as
                                                                                                                                                        such as oxygenates.                       shale gas.









            Features                                                                                                                      Inorganic gas                                                             Hydrocarbon
                                                                                                                                          analysis system                                                           analysis system
            High-Sensitivity Detectors Support a Wide Variety of Analyses                                                                 This system is able to                                                    This system is able to
                                                                                                                                          measure hydrogen and                                                      measure hydrocarbons that
                                                                                                                                          various other inorganic                                                   are generated, such as from
                       Barrier Discharge Ionization Detector (BID-2030)  Electron Capture Detector (ECD-2010 Exceed)                      gases.                                                                    catalyst reactions.
                                                                                    ECD cell
                                                                         Electrode
                                                                                         ˡ N 2 gas
                               Quartz tube  He plasma  He
                               (dielectric substance)
                               Column                                                    N 2 gas ˠ
                                                                           Sample


                                                                                                                                                        Refinery gas analysis system              Public utility natural gas analysis system
                                                                                                                                                        This system is able to analyze            This system is able to calculate
                                                                                                                                                        components in gas from petroleum          calorific values from measurements
                                                                                                                                                        refineries.                               of natural gas.

                       Flame Ionization Detector (FID-2030)           Flame Photometric Detector (FPD-2030)
                                                                                                                                      Faster Analysis with Hydrogen Carrier Gas
                             Collector                                           Lens                                                                                                                        Hydrogen
                                                                                                                                      Hydrogen can be a safe and highly effective carrier gas. As a highly efficient carrier gas with   sensor
                                            Nozzle
                                                                       Quartz                                                         a flat Van Deemter curve, it maintains its separation efficiency across a wide linear velocity
                                                                       tube
                                                                                                                                      range. This makes it both a good substitute for Helium and also a great choice for speeding
                                                                                                                                      up analysis times. We know safety is paramount, which is why the Nexis GC-2030 offers an
                                                                                   Filter
                                                                                                                                      optional built-in hydrogen sensor*. It not only maintains a safe standby mode for early
                                                                                                                                      detection of any potential leaks, but also shuts off hydrogen flow. The main unit also
                                                                                                                                      includes an automatic carrier gas leak check function, which is very helpful when using
                                                                                                                                      hydrogen as a carrier gas.
                                                                                                                                      * Optional                                                           Hydrogen Sensor Monitors Inside the GC Oven

      4                                                                                                                                                                                                                                        5
   1   2   3   4   5   6   7   8   9