Page 19 - Automotive Solution for Automotive
P. 19

Structural Analysis of Lithium-Ion Rechargeable  Compression Characteristics Evaluation of  Particle Size Distribution Measurement of Cathode/Anode Active Materials
 Battery Active Materials and Various Materials  Anode Active Material Particles
            SALD-7500 nano  Nanoparticle Size Analyzer
 XRD-6100  X-Ray Diffractometer  MCT Series  Micro Compression Testing Machines
            This analyzer measures the distribution of particle
 X-ray diffractometers are used in a wide range of   This series of testing machines measures the   size of cathode and anode active materials, for
 fields related to new materials, ceramics, metals,   pressure crack strength of individual   example. It utilizes the laser diffraction/scattering
 semiconductors, and polymers, and the number of   particulates (with a diameter 1 µm or more).   method and incorporates a UV semiconductor laser
 specimens to be measured in each field is diverse.   As a result, the compression characteristics of   light source (wavelength 375 nm), thus enabling the   Normalized Particle Amount
 For example, with batteries, the crystalline structure   anode active material particles can be   measurement of particle sizes of 10 nm to 300 µm.
 of cathode and anode active materials and their   evaluated. Also, by adding on the side   Various options, including a high-concentration
 orientation and size can be analyzed. With separators,   observation kit (option), the fracture process   sample measurement system and software for   Particle Diameter(nm)
 material quality can be qualitatively analyzed and   of anode powders can be observed and   gathering data at 1-second intervals, are also   Evaluation of the Presence of 5 µm Particles Contained in a 90 nm
 the degree of crystallinity, orientation, and other   compression characteristics data can be linked   available.  Particulate Sample
 properties can be analyzed as well. A polycapillary   with images.
 optical system also enables high-sensitivity analysis.

 I (CPS)  25000  [Group: LIB, Data: cathode material (wide)]  Force - Displacement Curves  Separation/Quantitation of Lithium-Ion Rechargeable Battery Electrolytic Solution Components
 20000
            Ion Chromatograph
 15000      This system can be used to separate and quantitatively analyze inorganic ions   5.0  mAU
 Force (mN)                                                           4.5                          Peak
 10000      contained in organic electrolyte solutions.               4.0                          1. PF6 -
            By combining the optimum units from a substantial product lineup, a wide
 5000                                                                 3.5
            measurement range from the ppb level up to the percent order can be   3.0
 0          accommodated. In addition to measuring concentration, systems can be   2.5
 10  20  30  40  50  60  70  80  90  100
 θ-2θ (°C)                                                            2.0
 Displacement (µm)  configured to measure the distribution of polymer molecular weights.          1
 Diffraction Pattern of Lithium-Ion Rechargeable Battery/             1.5
 Cathode Materials  Compression Test Results of 3 Types of Separators  1.0
                                                                      0.5
                                                                      0.0
 Non-Contact Elongation/Width Measurement of  Nanoparticle Measurement of Cathode Materials  -0.5  0.0  2.5  5.0  7.5  10.0  12.5  15.0  17.5  min
 Films and Foil Used as Separators
 IG-1000 Plus  Single Nanoparticle Size Analyzer                 LC Analysis of PF6- (Hexafluorophosphate Ions) Contained in Electrolytic Solution
 Precision Universal Testing Machines  With ternary system cathode materials
 TRViewX   used in lithium-ion rechargeable
 Video Type Non-Contact Extensometer/Width Sensor  batteries becoming more and more
 The elongation and width of polymer films   minute, this analyzer is suited to   Tensile Strength Evaluation of Electrolyte Films  High-Sensitivity Inorganic Gas Analysis
 used as separators for lithium-ion rechargeable   particle size measurement in the nano   MST-1 Micro Autograph  GC-2014
 batteries can now be measured. Plastics,   order, the final target measurement   Gas Chromatograph
 metals, foil, etc. can also be measured in   level.  This tester is ideal for the strength evaluation of
 addition to films.  electronic parts, microdevices, ultrafine wires, and   This instrument can measure down to the ppm
            other micro specimens. High-precision drive and      region, which could not be analyzed by
            measuring systems enable the measurement and         conventional TCD. It can measure CO in gas
            control of micro test forces and displacement to     emissions from reformers with high sensitivity.
 Thermal Characteristics Evaluation of Electrolytes, Separators, and Other Polymer Materials for Lithium-Ion Rechargeable Batteries  obtain various data. Also available are a
            stereomicroscope and an X-Y stage for simplifying
 DSC-60 Plus/60A Plus  Differential Scanning Calorimeter  TMA-60/60H  Thermal Analyzer
            the positioning and observation of specimens.
 This calorimeter is useful for evaluating thermal   This instrument is useful for evaluating the
 characteristics such as melting of the separators   expansion/contraction behavior of battery
 and transformation/decomposition of electrolytes   members, especially separators, caused by
 during heating. Features of this calorimeter   heating. The newly adopted digital displacement
 include a low noise level of 0.5 µW or less, high   sensor demonstrates little temperature drift, thus
 sensitivity, and high resolution.  assuring stable measurement. High linearity is
 The cooling process can also be easily measured   also achieved in spite of its ±5 mm wide   Evaluation of Reformers
 since the calorimeter has a built-in liquid   measurement range.
            IRA-208+CFP-8000                                     CGT-7100
 nitrogen cooling trough.
            Multicomponent Continuous Gas Analyzer               Portable Continuous Gas Analyzer
            Continuously measure three components, CO, CO2,      In addition to measuring low concentrations of CO
            CH4, emitted from the gas reformer.                  emitted from the gas reformer, this portable size
                                                                 infrared gas analyzer can also measure up to two
                                                                 other components, such as CO2 and CH4.








 Measurement of Melting of 3 Types of Separators  Measurement of Contraction Behavior of Separators by TMA
                                  Suspension and Other Power   Engines, Motors, and   Lithium-Ion Rechargeable  Electronic Instrumentation
                 Bodies and Interiors
                                  Transmission Systems  Power Sources     Batteries and Fuel Cells  Components
 18         This page may contain references to products that are not available in your country. Please contact us to check the availability of these products in your country.  19
   14   15   16   17   18   19   20   21   22   23   24