Page 24 - Automobile Evaluation Instruments
P. 24

Structural Analysis of Lithium-Ion Rechargeable    Compression Characteristics Evaluation of                             Particle Size Distribution Measurement of Cathode/Anode Active Materials
                      Battery Active Materials and Various Materials     Anode Active Material Particles                                      SALD-7500 nano Nanoparticle Size Analyzer
                    XRD-6100 X-Ray Diffractometer                      MCT Series Micro Compression Testing Machines                          This analyzer measures the distribution of particle size of cathode and   particle sizes of 10 nm to 300 µm. Various options, including a

                    X-ray diffractometers are used in a wide range of fields related to new   This series of testing machines measures the pressure crack strength of   anode active materials, for example. It utilizes the laser   high-concentration sample measurement system and software for
                    materials, ceramics, metals, semiconductors, and polymers, and the   individual particulates (with a diameter 1 µm or more). As a result, the   diffraction/scattering method and incorporates a UV semiconductor laser   gathering data at 1-second intervals, are also available.
                    number of specimens to be measured in each field is diverse. For example,   compression characteristics of anode active material particles can be   light source (wavelength 375 nm), thus enabling the measurement of
                    with batteries, the crystalline structure of cathode and anode active   evaluated. Also, by adding on the side observation kit (option), the fracture
                    materials and their orientation and size can be analyzed. With separators,   process of anode powders can be observed and compression
                    material quality can be qualitatively analyzed and the degree of crystallinity,   characteristics data can be linked with images.
                    orientation, and other properties can be analyzed as well. A polycapillary
                    optical system also enables high-sensitivity analysis.                                                                                                                        Normalized Particle Amount
                                                                                                 Force - Displacement Curves
                                                [Group: LIB, Data: cathode material (wide)]
                                                                                                                                                                                                               Particle Diameter(nm)
                                                                                               Force (mN)                                                                                          Evaluation of the Presence of 5 µm Particles Contained in a 90 nm
                                                                                                                                                                                                               Particulate Sample
                                                                                                                                               Separation/Quantitation of Lithium-Ion Rechargeable Battery Electrolytic Solution Components
                                                                                                   Displacement (µm)
                                                                θ - 2θ (°C)
                                       Diffraction Pattern of Lithium-Ion Rechargeable Battery/Cathode Materials  Compression Test Results of 3 Types of Separators  Prominence HIC-SP Ion Chromatograph
                                                                                                                                              This system can be used to separate and
                                                                                                                                                                                  mAU
                                                                                                                                              quantitatively analyze inorganic ions contained   5.0       Peak
                     Non-Contact Elongation/Width Measurement of        Nanoparticle Measurement of Cathode Materials                         in organic electrolyte solutions.  4.5                      1. PF6 -
                                                                                                                                                                                4.0
                     Films and Foil Used as Separators                                                                                        By combining the optimum units from a   3.5
                                                                       IG-1000 Plus Single Nanoparticle Size Analyzer                         substantial product lineup, a wide measurement   3.0
                    TRViewX Video Type Non-Contact Extensometer/Width Sensor  With ternary system cathode materials used in lithium-ion rechargeable   range from the ppb level up to the percent   2.5  1
                                                                                                                                                                                2.0
                    The elongation and width of polymer films used as separators for   batteries becoming more and more minute, this analyzer is suited to   order can be accommodated. In addition to   1.5
                                                                                                                                                                                1.0
                                                                                                                                              measuring concentration, systems can be
                    lithium-ion rechargeable batteries can now be measured. Plastics, metals,   particle size measurement in the nano order, the final target measurement   configured to measure the distribution of   0.5
                                                                                                                                                                                0.0
                    foil, etc. can also be measured in addition to films.  level.                                                             polymer molecular weights.        -0.5
                                                                                                                                                                                  0.0  2.5  5.0  7.5  10.0  12.5  15.0  17.5  min
                                                                                                                                                                                            -
                                                                                                                                                                                   LC Analysis of PF6  (Hexafluorophosphate Ions)
                                                                                                                                                                                       Contained in Electrolytic Solution
                         Width reduction                                                                                                     Micro Autograph MST-I Micro Strain Tester          GC-2014 Gas Chromatograph
                                                                                                                                                                                                  High-Sensitivity Inorganic Gas Analysis
                                                                                                                                               Tensile Strength Evaluation of Electrolyte Films
                                                                                                                                              This tester is ideal for the strength evaluation of   This instrument can measure down to the
                                                                                                                                              electronic parts, microdevices, ultrafine wires,   ppm region, which could not be analyzed
                              length elongation
                       Width reduction and length elongation graph                                                                            and other micro specimens. High-precision          by conventional TCD. It can measure CO in
                            of separator’s tensile test                                                                                       drive and measuring systems enable the             gas emissions from reformers with high
                                                                                                                                              measurement and control of micro test forces       sensitivity.
                                                                                                                                              and displacement to obtain various data. Also
                                                                                                                                              available are a stereomicroscope and an X-Y
                     Thermal Characteristics Evaluation of Electrolytes, Separators, and Other Polymer                                        stage for simplifying the positioning and
                     Materials for Lithium-Ion Rechargeable Batteries                                                                         observation of specimens.

                    DSC-60 Plus/60A Plus Differential Scanning Calorimeter  TMA-60/60H Thermal Analyzer
                    This calorimeter is useful for evaluating thermal characteristics such as   This instrument is useful for evaluating the expansion/contraction behavior
                    melting of the separators and transformation/decomposition of electrolytes   of battery members, especially separators, caused by heating. The newly
                    during heating. Features of this calorimeter include a low noise level of 0.5   adopted digital displacement sensor demonstrates little temperature drift,
                    µW or less, high sensitivity, and high resolution.  thus assuring stable measurement. High linearity is also achieved in spite of   Evaluation of Reformers
                    The cooling process can also be easily measured since the calorimeter has a   its ±5 mm wide measurement range.
                    built-in liquid nitrogen cooling trough.                                                                                 CGT-7100 Portable Continuous Gas Analyzer
                                                                                                                                              In addition to measuring low concentrations
                                                                                                                                              of CO emitted from the gas reformer, this
                                                                                                                                              portable size infrared gas analyzer can also
                                                                                                                                              measure up to two other components, such as
                                                                                                                                              CO  and CH .
                                                                                                                                                     4
                                                                                                                                                2




                                        Measurement of Melting of 3 Types of Separators  Measurement of Contraction Behavior of Separators by TMA
                                                                                                                                                 Engines, Motors, and   Bodies and Interiors  Lithium-Ion Rechargeable
                                                                                                                                                 Power Sources                         Batteries and Fuel Cells
             24                                                                                                                                  Suspension and Other Power   Electronic Instrumentation  Environmental   This page may contain references to products that are not available in your country.  25
                                                                                                                                                                     Components
                                                                                                                                                 Transmission Systems
                                                                                                                                                                                       Conservation
                                                                                                                                                                                                      Please contact us to check the availability of these products in your country.

          島津-自動車関連カタログ 英文.indd   24                                                                                      16/05/02   13:47