Page 18 - Shimadzu UV-3600 Plus
P. 18
Accessories Integrating sphere units.
Integrating Sphere Attachment (ISR-603) Integrating Sphere Attachment (ISR-1503)
(P/N 207-20100-58) (P/N 207-20900-58)
Basic Measurement
Film Holder Rotating Film Holder Multi-Cell Sample Compartment
(P/N 204-58909) (P/N 206-28500-41) (Six Cells) (P/N 206-69160-41)
This attachment enables relative diffuse or specular reflectance measurements. The This integrating sphere with a 150 mm internal diameter and maximum 4.0 %
angle of incidence to the sample can be set by setting it to zero or eight degrees in aperture ratio is compliant with a variety of regulations. The measurement
This holder is used to hold films, filters, and other This film holder enables in-plane rotation of samples This holds up to six cells on the sample side. It is combination with functionality for switching between sample and reference sides wavelength range is 220 to 2500 nm. A small sample holder for transmittance,
items. It is compatible with sample sizes between a centered on the optical axis. It is compatible with controlled automatically. of the spectrophotometer. The measurement wavelength range is 220 to 2600 a standard cell holder for direct detection, a powdered sample holder, a film
minimum W16 × H32 mm and maximum W80 × sample sizes up to 33 × 30 mm. nm. It is compatible with reflectance samples up to 100 mm in diameter and 15 holder, and other dedicated accessories are available.
H40 mm. mm thick.
Multipurpose Large-Sample Absolute Reflectance Attachments Variable Angle Measurement Unit
Compartment MPC-603A for MPC-603A (P/N 207-23490-42)
Short Optical Path, Long Optical Path, Micro-Volume Measurement (P/N 207-23550-41)
Long-Path Rectangular Cell Holder Spacers for Short-Path Cells Super-Micro Cell Holder
(P/N 204-23118-01) (P/N 204-21473-0X) (P/N 206-14334)
Optical path length of the cell
This multipurpose sample compartment can be used to These attachments are installed in a multipurpose This device enables absolute reflectance
freely measure the transmittance or reflectance of large-sample compartment to enable absolute measurements of solid samples, with the incident
variously shaped samples. The measurement wavelength specular reflectance measurements of solid samples. and reflection angles set to any angle. Measurement
range is 220 to 2600 nm. The compatible sample size range is 20 to 150 mm wavelength range is 250 to 1650 nm. It is
This holds rectangular cells with an optical path This standard cell P/N Available cells This cell holder is for supermicro cells. Volumes It is compatible with transmittance sample sizes up to 305 square and up to 30 mm thick. A sample base plate compatible with sample sizes from 20 to 70 mm
length of 10, 20, 30, 50, 70, or 100 mm. holder is required for -01 2mm between 50 and 200 L can be measured, mm in diameter and 50 mm thick or up to 204 mm in integrating sphere set is required. square and between 2 and 15 mm thick. The
short optical path cells. -02 5mm depending on the type of black cell used. diameter and 300 mm thick, or reflectance sample sizes incident angle can be set between 5 and 70 degrees.
-03 1mm up to 305 mm in diameter and 50 mm thick. P/N Incident angle Wavelength range
206-16817-58 5° 300 to 2400 nm
206-16100-58 12° 300 to 2500 nm
Constant-Temperature Measurement 206-15001-58 30° 300 to 2300 nm
300 to 2300 nm
206-15002-58
45°
Constant-Temperature Cell Holder Thermoelectrically Temperature- Thermoelectric Single-Cell Holder Large Polarizer Assy / Powdered Sample Holder Micro Sample Holder
(P/N 202-30858-44) Controlled Cell Holder (TCC-100) (S-1700) (P/N 206-23900) Polarizer Assys (for Integrating Sphere) (P/N 206-28055-41)
(P/N 206-29510) (P/N 206-89065-41)
This cell holder controls the cell temperature by This device can control the temperature of cells on This holder (including a stirrer) can be These enable control of polarization characteristics of This powdered sample holder is for installation in an This holds small samples against the integrating
circulating constant-temperature water. The both the sample and reference side. The programmed to increase/decrease the temperature incident light on samples. integrating sphere. sphere.
operating temperature range is 5 to 90 °C (requires temperature-control range is 7 to 60 °C. The on the sample side. The temperature-control P/N Type Wavelength range It is compatible with sample sizes from 5 to 10 mm
a separate constant-temperature water circulator). temperature can be adjusted only on the sample side range is 0 to 110 °C. Cooling water must be 206-15694-40 Large type 250 to 2300 nm square and between 0.5 and 2 mm thick.
A four-cell model is also and 6 sets are available (P/N 206-29500). The circulated to cool the Peltier element. 206-13236-41 Type I 400 to 800 nm
available (P/N: 204-27206-02). temperature-control range of 6 sets is 16 to 60 ° C.
206-13236-42 Type II 260 to 700 nm
206-13163-40 Type III 260 to 2300 nm
Reflectance Measurement
Specular Reflectance Measurement Attachment (5° Incident Angle) Various other accessories
(P/N 206-14046-58)
Liquid Samples Solid Samples
This device enables specular reflectance measurements. The angle of incidence to the sample is 5 degrees.
It is compatible with sample sizes from 7 mm in diameter up to 160 × 100 mm and up to 15 mm thick. https://www.shimadzu.com/an/molecular_spectro/uv/accessory/liquid/guide.html https://www.shimadzu.com/an/molecular_spectro/uv/accessory/solid/guide.html
18 19