Page 18 - Shimadzu UV-2600-2007i
P. 18
Accessories
Basic Measurement
Film Holder Rotating Film Holder Multi-Cell Sample Compartment
(P/N 204-58909) (P/N 206-28500-41) (Six Cells) (P/N 206-69160-41)
This holder is used to hold lms, lters, and other items. It is This lm holder enables in-plane rotation of samples This holds up to six cells on the sample side. It is controlled
compatible with sample sizes between a minimum W16 × centered on the optical axis. It is compatible with sample automatically.
H32 mm and maximum W80 × H40 mm. sizes up to 33 × 30 mm.
Short Optical Path, Long Optical Path, Micro-Volume Measurement
Long-Path Rectangular Cell Holder Spacers for Short-Path Cells Super-Micro Cell Holder
(P/N 204-23118-01) (P/N 204-21473-XX) (P/N 206-14334)
Optical path length of the cell
This holds rectangular cells with an optical path length of This standard cell holder is P/N Available cells This cell holder is for supermicro cells. Volumes between 50
10, 20, 30, 50, 70, or 100 mm. required for short optical path -01 2 mm and 200 L can be measured, depending on the type of
cells. -02 5 mm black cell used.
-03 1 mm
Constant-Temperature Measurement
Constant-Temperature Cell Holder Thermoelectrically Temperature- Tm Analysis System (TMSPC-8)
(P/N 202-30858-44) Controlled Cell Holder (TCC-100) (P/N 206-24350)
(P/N 206-29510)
This cell holder controls the cell temperature by circulating This device can control the temperature of cells on both the This system is used to analyze the melting temperature (Tm)
constant-temperature water. The operating temperature sample and reference side. The temperature-control range is of nucleic acids (such as DNA and RNA). The temperature-
range is 5 to 90 °C (requires a separate constant- 7 to 60 °C. The temperature can be adjusted only on the control range is 0 to 110 °C. Cooling water must be
temperature water circulator). A four-cell model is also sample side and 6 sets are available (P/N 206-29500). The circulated to cool the Peltier element.
available (P/N: 204-27206-02). temperature-control range of 6 sets is 16 to 60 °C. A USB
adapter CPS (P/N 206-25234-91) is required.
Automatic Analysis
Sipper Units Auto Sample Changer (ASC-5) Autosampler (ASX-560/280)
(P/N 206-23790-XX) (P/N 206-23810-91)
This device aspirates liquid samples using a peristaltic pump. If the ASC-5 is combined with a sipper unit or syringe sipper, If the ASX-560 is combined with a sipper unit or syringe
The ow cell shapes have types. it is possible to con gure an automated multisample sipper, it is possible to con gure an automated multisample
P/N Model Flow cell shapes measurement system for liquid samples. A USB adapter ASC measurement system for liquid samples. A CETAC
-51 160L L model (P/N 206-25235-91) is required. connection kit (P/N206-26525-91) and automatic analysis
-52 160T Triple-pass model software (P/N207-25807-91) are required.
-53 160C Constant-temperature model Model Number of analytes
-54 160U Ultra-micro volume model ASX-560 240 analytes
ASX-280 120 analytes
18