Page 14 - Shimadzu TOC-L
P. 14
Compatibility of Options and Special Accessories
˓: Compatible, ʵ: Not compatible
Type Name TOC-LCSH/CPH TOC-LCSN/CPN Explanation
Accessories for 9mL vial
*1
Options ASI-L 638-92327-41 ˓ ˓
autosampler 9 mL vial (100 pcs.) ˓ ˓
638-93199-58 638-53096
(for 24 mL vial) Accessories for 24mL via ˓ ˓
638-92325-41
638-93200-58 24 mL vial (100 pcs.)
(for 9 mL / ˓ ˓
40 mL vial) 638-41462 See page 12.
24 mL vial septum (100 pcs.) Vial sets do not include vials.
038-00165-61 ˓ ˓ Please purchase separately.
24 mL vial cap (100 pcs.) ˓ ˓
638-20074-01
Accessories for 40mL vial
638-92326-41 ˓ ˓
40 mL vial
(with septum, 72 pcs.) ˓ ˓
038-00158-11
*1
OCT-L 8-port sampler See page 12.
638-93201-58 (one unit) ˓ ˓ Up to two OCT-L units can be connected. Only one can be connected
638-93202-58 (two units) when the POC kit is used.
TNM-L TN unit See page 13.
638-91108-58 ˓ ˓
SSM-5000A solid sample combustion unit ˓ ˓ See page 13.
638-93210
Carbon dioxide, hydrocarbons and other carbon-containing
Carrier gas puri cation kit
Special ʔ ˓ compounds are removed from compressed air and other
Accessories 638-41447-04 pressurized gases, so that they can be used as carrier gas.
High-purity nitrogen gas (min. 1 ppm of each CO, CO2 and
HC) can be used as the carrier gas. When this option is used,
Nitrogen carrier gas kit the measurement range for both TC and IC expands from the
638-42054-02 ˓ ˓
conventional range (0 to 500 µg/L) to 0 to 100 mg/L. When
using TNM-L, this kit cannot be used.
Samples can be injected manually using a micro syringe. Gas
Manual injection kit samples and aqueous samples can be injected.
638-93149-03 ˓ ʔ
TC and CO2 measurements in gas samples can be performed.
POC measurement kit This kit enables measurement of the volatile organic carbon (POC)
For TOC-LCPN/CSN: 638-42101-01 ˓ ˓ driven from the sample during the sparging process at room
For TOC-LCPH/CSH: 638-42101-02 temperature.
Cell switching valve set ˓ ˓ This option for the SSM-5000A enables high-sensitivity
638-56239-41 measurement of solid samples.
Magnetic stirrer This option for the ASI-L enables agitation of 24 ml and 40 ml
For 24 mL vial: 638-67099-41 ˓ ˓ vial samples. (If 24 mL vials are used, vials No. 1 to No. 85 of the
For 40 mL vial: 638-67100-41 93 total vials can be stirred.)
This kit changes the sample ow line diameter from 0.5 mm to
Suspended sample kit 0.8 mm, enabling the injection of larger suspended substances
638-41586 ˓ ˓
into the combustion tubes. (Parts for ASI-L are not included.)
Suspended sample kit, with ASI parts ˓ ˓ ASI-L ow line parts are added to the suspended sample kit.
638-93151-04
External sparging kit Sparging can be performed with any sample container.
638-77183-40 ˓ ˓
External sparging kit, with ASI parts ˓ ˓ Sparging can be performed inside ASI-L vials.
638-77183-41
This kit enables the measurement of smaller volumes of samples.
Example of sample consumption: Standard speci cations: 8 mL/3
Kit for small sample volumes ˓ ʔ measurements ˠ Using this kit: 5 mL/3 measurements.However,
638-59328 there are some performance limits such as maximum sensitivity range
is about 0-1 mg/L, maximum measuring range decreases, ASI-L and
external sparging kit need to measure NPOC automatically.
High Conc. TC ˓ ˓
638-42167-41
High Conc. IC These kits enable measurement of samples containing
638-42167-42 ˓ ʔ sedimentary organic matter with good repeatability. There
High Suspension Kits are kit for high concentration sample (injection volume 80 µL)
Low Conc. TC ˓ ˓ and for low concentration sample (injection volume 150 µL). It
638-42167-43 doesn’t support IC measurements with TOC-L standard model.
Low Conc. IC
638-42167-44 ˓ ʔ
This kit effectively removes corrosive gases produced when
B-type halogen scrubber ˓ ˓ measuring samples containing salts, thereby easing NDIR cell
638-52572-03
degradation.
When measuring samples containing salts, this kit extends the
High-salt sample combustion tube kit lifetime of combustion tubes and catalysts, reducing maintenance
For TOC-LCPN/CSN: 638-93176-01 ˓ ˓ frequency. It enables seawater measurement approx. 2,500 times
For TOC-LCPH/CSH: 638-93176-02
by injecting 40 µL. (It’s not a guaranteed value.)
LAN board Data can be output via the LAN board.
638-79070-41 ˓ ˓
Air supply pipe set ˓ ˓ Includes a 20 m carrier gas pipe.
638-41204
ˎ1: Select either ASI-L or OCT-L. They cannot be used simultaneously.