Compatibility of Options and Special Accessories

                                                                                              ˓: Compatible, ʵ: Not compatible
                 Type               Name               TOC-LCSH/CPH  TOC-LCSN/CPN          Explanation
                                    Accessories for 9mL vial
                            *1
                Options   ASI-L     638-92327-41         ˓           ˓
                          autosampler  9 mL vial (100 pcs.)  ˓       ˓
                            638-93199-58   638-53096
                          (for 24 mL vial)  Accessories for 24mL via  ˓  ˓
                                      638-92325-41
                          638-93200-58   24 mL vial (100 pcs.)
                          (for 9 mL /                    ˓           ˓
                            40 mL vial)  638-41462                           See page 12.
                                    24 mL vial septum  (100 pcs.)            Vial sets do not include vials.
                                      038-00165-61       ˓           ˓       Please purchase separately.
                                    24 mL vial cap (100 pcs.)    ˓   ˓
                                    638-20074-01
                                    Accessories for 40mL vial
                                      638-92326-41       ˓           ˓
                                    40 mL vial
                                      (with septum, 72 pcs.)    ˓    ˓
                                    038-00158-11
                            *1
                         OCT-L  8-port sampler                               See page 12.
                           638-93201-58 (one unit)       ˓           ˓       Up to two OCT-L units can be connected. Only one can be connected
                         638-93202-58 (two units)                            when the POC kit is used.
                         TNM-L TN unit                                       See page 13.
                         638-91108-58                    ˓           ˓
                         SSM-5000A solid sample combustion unit  ˓   ˓       See page 13.
                           638-93210
                                                                             Carbon dioxide, hydrocarbons and other carbon-containing
                         Carrier gas puri cation kit
                 Special                                 ʔ           ˓       compounds are removed from compressed air and other
               Accessories    638-41447-04                                   pressurized gases, so that they can be used as carrier gas.
                                                                             High-purity nitrogen gas (min. 1 ppm of each CO, CO2 and
                                                                             HC) can be used as the carrier gas. When this option is used,
                         Nitrogen carrier gas kit                            the measurement range for both TC and IC expands from the
                         638-42054-02                    ˓           ˓
                                                                             conventional range (0 to 500 µg/L) to 0 to 100 mg/L. When
                                                                             using TNM-L, this kit cannot be used.
                                                                             Samples can be injected manually using a micro syringe. Gas
                         Manual injection kit                                samples and aqueous samples can be injected.
                         638-93149-03                    ˓           ʔ
                                                                             TC and CO2 measurements in gas samples can be performed.
                         POC measurement kit                                 This kit enables measurement of the volatile organic carbon (POC)
                         For TOC-LCPN/CSN: 638-42101-01   ˓          ˓       driven from the sample during the sparging process at room
                         For TOC-LCPH/CSH: 638-42101-02                      temperature.
                         Cell switching valve set        ˓           ˓       This option for the SSM-5000A enables high-sensitivity
                         638-56239-41                                        measurement of solid samples.
                         Magnetic stirrer                                    This option for the ASI-L enables agitation of 24 ml and 40 ml
                         For 24 mL vial: 638-67099-41    ˓           ˓       vial samples. (If 24 mL vials are used, vials No. 1 to No. 85 of the
                           For 40 mL vial: 638-67100-41                      93 total vials can be stirred.)
                                                                             This kit changes the sample  ow line diameter from 0.5 mm to
                         Suspended sample kit                                0.8 mm, enabling the injection of larger suspended substances
                         638-41586                       ˓           ˓
                                                                             into the combustion tubes. (Parts for ASI-L are not included.)
                         Suspended sample kit, with ASI parts   ˓    ˓       ASI-L  ow line parts are added to the suspended sample kit.
                         638-93151-04
                         External sparging kit                               Sparging can be performed with any sample container.
                         638-77183-40                    ˓           ˓
                         External sparging kit, with ASI parts   ˓   ˓       Sparging can be performed inside ASI-L vials.
                         638-77183-41
                                                                             This kit enables the measurement of smaller volumes of samples.
                                                                             Example of sample consumption: Standard speci cations: 8 mL/3
                         Kit for small sample volumes    ˓           ʔ       measurements ˠ Using this kit: 5 mL/3 measurements.However,
                         638-59328                                           there are some performance limits such as maximum sensitivity range
                                                                             is about 0-1 mg/L, maximum measuring range decreases, ASI-L and
                                                                             external sparging kit need to measure NPOC automatically.
                                       High Conc. TC     ˓           ˓
                                       638-42167-41
                                       High Conc. IC                         These  kits  enable measurement of  samples containing
                                       638-42167-42      ˓           ʔ       sedimentary organic matter with good repeatability. There
                         High Suspension Kits                                are kit for high concentration sample (injection volume 80 µL)
                                       Low Conc. TC      ˓           ˓       and for low concentration sample (injection volume 150 µL). It
                                       638-42167-43                          doesn’t support IC measurements with TOC-L standard model.
                                       Low Conc. IC
                                       638-42167-44      ˓           ʔ
                                                                             This kit effectively removes corrosive gases produced when
                         B-type halogen scrubber         ˓           ˓       measuring samples containing salts, thereby easing NDIR cell
                         638-52572-03
                                                                             degradation.
                                                                             When measuring samples containing salts, this kit extends the
                         High-salt sample combustion tube kit                lifetime of combustion tubes and catalysts, reducing maintenance
                         For TOC-LCPN/CSN: 638-93176-01  ˓           ˓       frequency. It enables seawater measurement approx. 2,500 times
                           For TOC-LCPH/CSH: 638-93176-02
                                                                             by injecting 40 µL. (It’s not a guaranteed value.)
                         LAN board                                           Data can be output via the LAN board.
                         638-79070-41                    ˓           ˓
                         Air supply pipe set             ˓           ˓       Includes a 20 m carrier gas pipe.
                           638-41204
            ˎ1: Select either ASI-L or OCT-L. They cannot be used simultaneously.