Page 8 - Shimadzu Nexera lite inert
P. 8
C190-E292A
PDA Detector Nexera lite inert
SPD-M40
Light source Deuterium (D2) lamp, tungsten lamp
Number of diode elements 1024
Wavelength range 190 to 800 nm
41% .
Wavelength accuracy ≤ ±1 nm
Wavelength repeatability ≤ ±0.1 nm High Performance Liquid Chromatograph
Slit width 1.2 nm, 8 nm
Spectral resolution ≤ ±1.4 nm Nexera lite inert
Drift* ʽ0.4×10 AU/h (under speci ed conditions, typically)
-3
Noise* ʽ6.0×10 AU (under speci ed conditions)
-6
Linearity* 2.5 AU (under speci ed conditions, typically)
Inert cell (optical path length: 10 mm, cell volume: 12 µL, equipped with temperature control function)
Recommended ow cell
Materials of wetted parts: PEEK, PFA, quartz
Sampling rate Max. 100 Hz (Single wavelength mode)
Cell temperature control range 19 to 50 ˚C, 1 ˚C step
UHPLC inert cell
(optical path length: 10 mm, cell volume: 8 µL, equipped with temperature control function)
Low-diffusion inert cell
Optional ow cell (optical path length: 5 mm, cell volume: 2.5 µL, equipped with temperature control function)
Inert cell
(optical path length: 10 mm, cell volume: 12 µL, equipped with temperature control function)
Available pH range 1 to 13 (Cell quartz might be damaged by a mobile phase of pH>10.)
Dimensions [mm], weight W 260 × D 500 × H 140 mm, 10 kg
Operating temperature range 4 to 35 ˚C
Power supply AC 100 to 240 V, 180 VA, 50/60 Hz
*when using inert ow cell for UHPLC analysis
pH monitor
pHM-40
Available pH range 1 to 14
Precision pH ±0.1 (under speci ed conditions)
Drift pH ±0.1/10 h (under speci ed conditions)
Maximum ow rate 10 mL/min
Allowable maximum pressure 0.1 MPa
Cell volume approx. 80 L
Available liquid temperature 4 to 60 °C
Q). Wetted materials glass, PEEK, PCTFE, silicon
Calibration point 1 to 5 point is settable.
Dimensions [mm], weight W 130 × D 393 × H 206, 6 kg
Power supply DC 5 V, 5 VA
Nexera and LabSolutions are trademarks of Shimadzu Corporation or its af liated companies in Japan and/or other countries.
For Research Use Only. Not for use in diagnostic procedures.
This publication may contain references to products that are not available in your country. Please contact us to check the availability of
these products in your country.
Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation,
its subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.
Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether
or not they are used with trademark symbol “TM” or “®”.
Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.
www.shimadzu.com/an/ The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice.
Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.
© Shimadzu Corporation, 2023 / First Edition: August 2022, 3655-04307-PDFIK, C190-E292A