Specifications Autosamplers
SIL-20AC (with inert kit) SIL-20A (with inert kit)
Injection method Total-volume injection, Variable injection volume (No sample loss by injection)
Inert kit : 20.0 MPa (Water Solvent) , 14.7 MPa (Organic Solvent)
System Controllers Allowable maximum pressure Inert kit with optional expansion 500 µL sample loop : 20.0 MPa (Water Solvent), 9.8 MPa (Organic Solvent)
0.1 to 50 µL (standard), 0.1 to 500 µL (optional)
SCL-40 CBM-40 CBM-40lite Injection volume (0.1 to 0.9 µL : 0.1 µL step, 1 to 500 µL : 1 µL step)
Touch panel
Monitors LabSolutions ™ LabSolutions LabSolutions Injection volume accuracy ≤ ±1% 50 µL injection, n=10
Web monitor Web monitor Web monitor 175 (1 mL sample vial), 105 (1.5 mL sample vial), 50 (4mL sample vial)
4*- "$ Samples for processing 192 (microtiter plate 96 well × 2 plates), 768 (microtiter plate 384 well × 2 plates)
Connectable unit Solvent delivery unit: Max. 4, Autosampler: 1, Column oven: Max. 4, Detector: Max. 2, etc.
4$-ô 8 4 Injection volume repeatability RSD ≤ 0.3% (10 µL injection)
Number of connectable units (Excluding built-in Carryover ≤ 0.005% (under speci ed conditions)
(Using option: 12)
solvent delivery unit) Sample cooler Standard equipment —
Event input/output Input: 1, output: 2 Sample cooler temperature C model : ±3 ˚C (microtiter plate and deep —
Analog board Up to 2 channels (option) Up to 1 channel (option) — accuracy well plate cannot be cooled ≤ ±6 ˚C, 1 ˚C.)
Communication Ethernet Wetted materials PEEK, PEEK blend, Ceramic
$#.ô Reservoir tray Built-in — Available pH range 1 to 14
W 260 × D 500 × H 140, W 260 × D 500 × H 72, Dimensions [mm], weight W 260 × D 500 × H 415 mm, 27 kg W 260 × D 509 × H 415 mm, 30 kg
Dimensions [mm], weight —
6 kg 5 kg Operating temperature range 4 to 35 ˚C
Operating 4 to 35 ˚C Power supply AC 100 to 240 V, 180 VA, 50/60 Hz
temperature range
Supplied from
Power supply AC 100 to 240 V, 50 VA, 50/60 Hz Column Ovens
solvent delivery unit
CTO-40C CTO-40S
Temperature control type Forced air circulation
Cooling method Electronic cooling
Solvent Delivery Unit Temperature control range Room temperature −10 ˚C to 100 ˚C Room temperature −10 ˚C to 85 ˚C
Temperature accuracy ± 0.5 ˚C ± 0.8 ˚C
LC-40i
Temperature precision ± 0.05 ˚C ± 0.1 ˚C
Pumping method Serial-type double plunger
Containable column size Up to 250 mm L. column × 6 Up to 100 mm L. column × 6
Water: 30 MPa (≤ 4.0000 mL/min) and number or 300 mm L. column × 3 or 300 mm L. column × 3
Allowable maximum pressure Organic solvents: 22MPa (≤ 4.0000 mL/min) Dimensions [mm], weight
-$ô J Water and Organic Solvents: 15 MPa (4.0001 to 5.0000 mL/min) W 260 × D 500 × H 415, 21 kg W 130 × D 500 × H 553, 15 kg
$50 $ $50 4 Operating temperature range 4 to 35°C
Flow rate setting range 0.0001 to 5.0000 mL/min AC 100 to 120 V / 220 to 240 V
±2% or ±2 µL/min Power supply (Automatic switching), AC 100 to 240 V, 300 VA, 50/60 Hz
Flow rate accuracy Whichever is greater (Speci ed conditions) 400 VA, 50/60 Hz
≤ 0.06% RSD or 0.02 minSD
Flow rate precision Whichever is greater UV-Vis Detectors
High-pressure gradient (2 or 3 solvents)
Gradient mode
Low-pressure gradient (4 solvents) SPD-40 SPD-40V
Gradient range of Light source Deuterium (D2) lamp Deuterium (D2) lamp, tungsten lamp
set concentrations 0 to 100% (0.1% step) Wavelength range 190 to 700 nm 190 to 1000 nm
Gradient concentration HPGE: ±1.0% (1 mL/min, 10 MPa, water / caffein aq.) 41% 7 Bandwidth 8 nm
accuracy LPGE: ±1.0% (1 mL/min, 10 MPa, water / caffein aq.) Wavelength accuracy ≤ ±1 nm
Wetted materials PEEK, ruby, sapphire, Per uoroelastomer, high molecular weight polyethylene Wavelength repeatability ≤ ±0.1 nm
-3
Available pH range 1 to 14 Drift* ʽ0.1 × 10 AU/h (under speci ed conditions, typically)
-6
Automatic rinsing kit Optional Noise* ʽ5.0 × 10 AU (under speci ed conditions)
Degassing unit 1 unit connectable Linearity* 2.5 AU (under speci ed conditions, typically)
Dimensions [mm], weight W 260 × D 500 × H 140 mm, 10 kg Recommended ow cell Inert cell (optical path length: 10 mm, cell volume: 12 µL, equipped with temperature control function)
Operating temperature range 4 to 35˚C Materials of wetted parts: PEEK, PFA, quartz
Power supply AC 100V to 240V, 150 VA, 50/60 Hz Sampling rate Max. 100 Hz (Single wavelength mode)
Cell temperature control
range 19 to 50 ˚C, 1 ˚C step
UHPLC inert cell
Degassing Units (optical path length: 10 mm, cell volume: 8 µL, equipped with temperature control function)
Low-diffusion inert cell
DGU-403 DGU-405 Optional ow cell (optical path length: 5 mm, cell volume: 2.5 µL, equipped with temperature control function)
Number of degassed solvents 3 5 Inert cell
%(6 Wetted materials PEEK, PTFE (optical path length: 10 mm, cell volume: 12 µL, equipped with temperature control function)
Degassed ow line capacity 400 L/1 line Available pH range 1 to 13 (Cell quartz might be damaged by a mobile phase of pH>10.)
Dimensions [mm], weight W 260 × D 500 × H 72, 4 kg Dimensions [mm], weight W 260 × D 500 × H 140 mm, 11 kg
Operating temperature range 4 to 35 ˚C Operating temperature range 4 to 35 ˚C
Power supply Supplied from solvent delivery unit Power supply AC 100 to 240 V, 150 VA, 50/60 Hz
*when using inert ow cell for UHPLC analysis
Nexera lite inert
High Performance Liquid Chromatograph