Specifications                                                                                         MALDI-8030
                                                                         Mass range      m/z 1 - 500,000
                                                                         Mass resolution  >5000 FWHM – ACTH 18-39 (m/z 2465)
                                                                                         <20 ppm with internal calibration
                                                                         Accuracy
                                                                                         <150 ppm with external calibration †
                                                                                         250 fmol – bovine serum albumin (loaded)
                                                                         Sensitivity
                                                                                         250 amol – Glu-1-Fibrinopeptide B (loaded)
                                                                         Size (w x d x h)  450 x 745 x 1055 mm [17.7” x 29.5” x 41.5”]
                                                                         Incl. stabilizer  600 x 745 x 1055 mm [23.6” x 29.5” x 41.5”]
                                                                         Weight          92 kg
                                                                         † Nearest neighbour external calibration on FlexiMass-SR48 target, within 30 minutes
                                                                         All performance data are acquired using standard test samples on a FlexiMass-SR48 stainless steel target.

                                                                         Installation requirements

                                                                                                        100 to 240 VAC, 50/60 Hz, 1000 VA single phase
                                                                         Utilities      Power
                                                                                                        A 'clean', stable and continuous mains supply is required for reliable operation
                                                                                                        ambient 18°C to 28°C for performance
                                                                                        Temperature range
                                                                         Environment                    ambient 15°C to 32°C for operation
                                                                                        Relative humidity  less than 70%, non-condensing

                                                                         Installation Example

                                                                                                          Dimensions (mm)   Weight
                                                                         No.  Description
                                                                                                         W      D      H     (kg)
                                                                          1   MALDI-8030                600    745   1055    92
                                                                              Control PC, monitor, keyboard   850   550   500   10
                                                                          2                                                                                                      t
                                                                              and mouse (reference)    approx. approx. approx. approx.
                                                                                                                                     200mm             600mm
                                                                          3   Table (reference)         1500   750    750
                                                                                                                                       1                   2           3









                                                                        MALDI Solutions, QC Reporter, SampleStation, AuraSolution, FlexiMass,
                                                                        TrueClean and WideBore are trademarks of Kratos Analytical Ltd.
                                                                        eMSTAT Solution is a trademark of Shimadzu Corporation.










                                                                                                    Discover application notes!

                                                                        Kratos Analytical Ltd.
                                                                        Wharfside, Trafford Wharf Road, Manchester M17 1GP, UK
                                                                        Phone: +44 161 888 4400  Fax. +44 161 888 4402
                                                                        URL http://www.shimadzu.com/an/


                                                                                                          For Research Use Only. Not for use in diagnostic procedures.
                                                                                                          This publication may contain references to products that are not available in your country. Please contact us to check the availability of
                                                                                                          these products in your country.
                                                                                                          Company names, products/service names and logos used in this publication are trademarks and trade names of Shimadzu Corporation,
                                                                                                          its subsidiaries or its affiliates, whether or not they are used with trademark symbol “TM” or “®”.
                                                                                                          Third-party trademarks and trade names may be used in this publication to refer to either the entities or their products/services, whether
                                                                                                          or not they are used with trademark symbol “TM” or “®”.
                                                                  Shimadzu Corporation                    Shimadzu disclaims any proprietary interest in trademarks and trade names other than its own.

                                                                                                          The contents of this publication are provided to you “as is” without warranty of any kind, and are subject to change without notice.
                                                                  www.shimadzu.com/an/                    Shimadzu does not assume any responsibility or liability for any damage, whether direct or indirect, relating to the use of this publication.

                                                                                                                                                            © Shimadzu Corporation 2021
                                                                                                                                                 First Edition: October 2021, Printed in UK MO473
   3   4   5   6   7   8