Page 6 - Shimadzu MALDI-8030
P. 6

SOLUTIONS FOR ALL YOUR APPLICATIONS                                                               STACKED WITH TECHNOLOGY


                   Regulatory & Manufacturing Labs                                                                                    Designed for Performance...











                  DUAL-POLARITY VERSATILITY...for manufacturing/GMP                                                                   ...Sensitivity and Resolution

                      Dual-polarity: flexibility of analytes for intact mass analysis
                      Integrated data security (facilitates 21CFR part 11 compliance): admin-controlled user logins and user traceability
                                                                                                                                        WideBore™ Ion Optics
                      Save methods: ideal for locked-down GMP protocols following method development and validation
                                                                                                                                        This patented technology significantly reduces
                      Wide mass range of analysis (up to m/z 500,000) for high mass drug conjugates                                                                                          incident UV      desorbed ions
                                                                                                                                        contamination from the desorbed MALDI sample. The    laser beam       accelerated
                                                                                                                                                                                                             through apertures
                      Automated lockmass feature: suitable for reproducible batch analysis of biosimilars                               near normal (on-axis) incidence of the MALDI laser
                                                                                                                                        beam and the camera view produce outstanding
                  Smart choices for (bio-)pharma, polymers, oligonucleotides, genetic testing, quality control.                                                                                                      electrodes
                                                                                                                                        efficiency of the MALDI source and high quality
                                                                                                                                        sample images. The strong electrostatic lens delivers
                                                                                                                                        high sensitivity and resolution.                   sample spot         desorbed neutral
                     Peptide QC in Biopharma                                                                                                                                             sample plate           matrix plume
                                                                                                                                                                                                    sample plate carrier
                                            2374.959  Class-leading mass resolution
                      100
                      90                               100  2374.959{r4731}
                      80  Positive mode                80
                      70  - intact species not detected  %Intensity  60
                      % Intensity  60                  40 20                                                                          ...Robustness
                      50
                      40
                                                2535.0
                      30                      -(2 x SO 3 )  0  2370  2375 m/z  2380  2385  100  2452.958{r5963}
                      20                           Intact species                         %Intensity 80 60
                      10                           not detected                           40                                                                             TrueClean™
                       0                                                                  20
                        1600  1800  2000  2200  2400  2600    100                          0
                                      m/z                      90                            2450  2455  2460                                                            Incorporated into the MALDI-8030, the Shimadzu patented
                                                                                                m/z
                                                                  Negative mode             100
                                                               80
                     An advantage of negative mode analysis can be seen   70  - partial loss of sulfo groups  2452.958  80 60  2532.911{r5938}                 electrodes  TrueClean technology is a unique design which enables seamless
                                                                                     2532.911
                     during QC of labile peptides from a manufacturing   % Intensity  60  - intact peptide detected  -SO 3  %Intensity  40                               self-cleaning of the ion optics, without breaking vacuum and no
                                                               50
                         ^*
                     batch . In this case the sulfated species are not   40        -SO 3    20 0                                                                         need to remove the ion optics. A fully automated process activated
                                                               30                              2530 2535 2540 2545                      refocused
                                                                                                 m/z
                     detected in positive ion mode (above) due to the   20                   100                                         laser spot                      by the user, the MALDI laser (same one used for sample analysis) is
                                                               10                 2373.031    80  2373.031{r5955}
                     preferential ionization, but are clearly seen in   0                     60                                                            sample plate  reflected off a mirror in the sample analysis chamber to remove
                                                                1600  1800  2000  2200  2400  2600  %Intensity  40                                  intermediate  carrier
                     negative ion mode (right) where the intact peptide      m/z              20                                          concave    laser focus         sample debris from the first lens, thereby extending the robustness
                                                                                                                                          reflector
                     and all sulfated species are detected.                                   0  2370  2375  2380                                                        of your system even further.
                                                                                                   m/z
                     *may require QC Reporter™ software
                     ^ Samples and data kindly obtained by permission from Bachem (UK) Ltd.
                     Clinical Sample Profiling
                     The Shimadzu MALDI-8030 is the sensible choice, offering fast sample introduction with a quick MALDI laser
                     and sample stage thereby providing a high-throughput for your time-to-result cycle.
                     The integrated barcode reader allows seamless
                     tracking to reduce misidentification errors when     Expert Opinion
                                                   *
                     used with the disposable FlexiMass slides  which
                     have been designed for biological use.   “ The new mass spectrometer was really   ”
                                                                easy to work with. It was perfect for our
                     *requires SampleStation™ and AuraSolution™ software   lipid application in melanoma screening.
                                                                          Dr Egoitz Astigarraga
                                                                        IMG Pharma Biotech, Spain


                                                                                                                                                                                                                    MALDI-8030
                                                                                                                                                                                                          Dual-Polarity Benchtop Linear MALDI-TOF Mass Spectrometer
   1   2   3   4   5   6   7   8