Page 7 - Shimadzu i-Series Method Transfer System
P. 7

Designed for User-Friendly Operability

               —Core Technologies That Provide a Solid Foundation for Analysis





               Forced Air Circulation Column Oven
               Supports Up to 85°C


               Forced air circulation provides higher column temperature
               stability. Heating capacity up to 85°C enables
               thermostatic analysis, such as for analyzing sugars.


               Autosampler Enhances Data Reliability


               The excellent reproducibility with a low injection volume
               less than 1  L and low carryover (max 0.0025%) maximize
               data reproducibility when migrating methods.


               Dual Temperature Control Cell Inhibits
               Baseline Fluctuations

               In addition to the flow cell temperature control function,
               the system also includes a function for controlling the
               temperature of the detector’s optical systems (TC-Optics).
               These functions minimize the influence of external air
               temperature variations to help ensure a stable baseline.

               Touch Panel Enables Sensory-Based
               Determination of the Operating Status

               The i-Series user interface features a flow line diagram
               that allows users to visually confirm the flow lines and
               columns being used. Switching between flow lines
               requires only one touch on the control panel, which
               significantly reduces the user operating time.















               The Compact Footprint Provides a              Automatically Switch Between Two
               Spacious Operating Environment                HPLC/UHPLC Flow Lines

               A single i-Series MT system can perform the work of   The system includes a 10-port flow line switching valve
               two LC systems, so the required installation space is   for two flow lines in the same system, one for HPLC and
               significantly reduced in comparison to existing LC   the other for UHPLC. The flow lines can be switched
               systems.                                      automatically using the software, which significantly
                                                             reduces the time and trouble involved in transferring
                                                             methods.