Automation and Labor-Savings with Macro Program Functions


            LabSolutions IR automates routine work, such as scanning, data manipulation, reporting, identification tests, and
            contaminants analysis. Launch programs from the Launcher or your PC desktop.



                                With LabSolutions IR, the following analysis operations can be automated
                                           for more labor-saving by using macro programs.

               Routine tasks: Measurement, peak detection, and printing  Contaminant analysis
                • Common routine tasks for IR analysis performed with just one click  • Easy and quick contaminant analysis. Just a few seconds until the
                 Identification tests for Pharmacopoeia and Food Additives standards  results are output
                                                                  Validation program that complies with the Japanese, European,
               Japanese Pharmacopoeia and food additive identification tests  Chinese, and United States Pharmacopoeias, and with ASTM standards
                • Automate pass/fail judgment of test samples      • Easy undertaking of instrument inspections in accordance with
                                                                    official regulations


                                                                                        r
                                                                                         k
                                                                              i
                                                                             t
                                                                                   W
                                                                               n

                                                                                      o
                                                                                e
            Easy Macro — Just a Single Click Launches Routine Work
            The "Easy Macro" function will create macros that are suitable for routine work,
            particularly when repetitive operations are used. The macro builder allows macros to be
            constructed by simply selecting and aligning operations from a list. Once constructed, the
            macros can be registered with the Launcher and desktop for quick execution. Operators
            who are not familiar with FTIR can easily operate the instrument.
                                   Easy Macro Operations
               Initialization of FTIR, configuration of scan parameters, spectrum measurement
               Data manipulations, search, quantitation, printing
               Repeat measurements, displaying messages, alarm sounds, external program execution








                                                                                      m
                                                                                       e
                                                                                        n
                                                                                   u
                                                                                    r
                                                                                     e
                                                                         g
                                                                          r
                                                                        ck
                                                                      Background measurement t
                                                                       a
                                                                              d
                                                                               meas
                                                                            un
                                                                           o
                                                                               Sample measurement

                          Print

                                                                                             ATR correction
                                                                           Search